Simulation research on the characteristics of a minitype neutron reference radiation field

In order to research the characteristics of minitype neutron reference radiation field regulated by ISO 8529 series standards, Monte Carlo simulation method was applied to calculate the ratio of room-scattered neutron response to the direct neutron response, neutron fluence and energy spectra in the...

Full description

Bibliographic Details
Main Authors: Song Zhang, Yi-Kun Qian, Yu-Chen Huang, Peng He, Peng Feng
Format: Article
Language:English
Published: Elsevier 2024-01-01
Series:Results in Physics
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2211379723010872
_version_ 1797350864997842944
author Song Zhang
Yi-Kun Qian
Yu-Chen Huang
Peng He
Peng Feng
author_facet Song Zhang
Yi-Kun Qian
Yu-Chen Huang
Peng He
Peng Feng
author_sort Song Zhang
collection DOAJ
description In order to research the characteristics of minitype neutron reference radiation field regulated by ISO 8529 series standards, Monte Carlo simulation method was applied to calculate the ratio of room-scattered neutron response to the direct neutron response, neutron fluence and energy spectra in the radiation field. Firstly, the characteristics of the field were investigated from the four physical factors as shielding materials, field sizes, shielding thicknesses and borated polyethylene with different boron contents. Secondly, the response of sphere instrument with different diameters in the field and the influence of instrument on the field were analyzed. The results showed that minitype neutron reference radiation field with a size of 2 m × 2 m × 2 m, a shielding material of 5 % borated polyethylene and a shielding thickness of 10 cm was expected to be used for the calibration of neutron measuring instrument.
first_indexed 2024-03-08T12:52:12Z
format Article
id doaj.art-3d48e648593d41289bc32e1e2ace45fa
institution Directory Open Access Journal
issn 2211-3797
language English
last_indexed 2024-03-08T12:52:12Z
publishDate 2024-01-01
publisher Elsevier
record_format Article
series Results in Physics
spelling doaj.art-3d48e648593d41289bc32e1e2ace45fa2024-01-20T04:45:20ZengElsevierResults in Physics2211-37972024-01-0156107294Simulation research on the characteristics of a minitype neutron reference radiation fieldSong Zhang0Yi-Kun Qian1Yu-Chen Huang2Peng He3Peng Feng4Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, ChinaKey Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, ChinaMetrology and Testing Center, China Academy of Engineering Physics, Mianyang 621900, ChinaKey Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, ChinaKey Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China; Corresponding author.In order to research the characteristics of minitype neutron reference radiation field regulated by ISO 8529 series standards, Monte Carlo simulation method was applied to calculate the ratio of room-scattered neutron response to the direct neutron response, neutron fluence and energy spectra in the radiation field. Firstly, the characteristics of the field were investigated from the four physical factors as shielding materials, field sizes, shielding thicknesses and borated polyethylene with different boron contents. Secondly, the response of sphere instrument with different diameters in the field and the influence of instrument on the field were analyzed. The results showed that minitype neutron reference radiation field with a size of 2 m × 2 m × 2 m, a shielding material of 5 % borated polyethylene and a shielding thickness of 10 cm was expected to be used for the calibration of neutron measuring instrument.http://www.sciencedirect.com/science/article/pii/S2211379723010872Neutron reference radiation fieldMinitypeInstrument responseNeutron fluenceNeutron energy spectra
spellingShingle Song Zhang
Yi-Kun Qian
Yu-Chen Huang
Peng He
Peng Feng
Simulation research on the characteristics of a minitype neutron reference radiation field
Results in Physics
Neutron reference radiation field
Minitype
Instrument response
Neutron fluence
Neutron energy spectra
title Simulation research on the characteristics of a minitype neutron reference radiation field
title_full Simulation research on the characteristics of a minitype neutron reference radiation field
title_fullStr Simulation research on the characteristics of a minitype neutron reference radiation field
title_full_unstemmed Simulation research on the characteristics of a minitype neutron reference radiation field
title_short Simulation research on the characteristics of a minitype neutron reference radiation field
title_sort simulation research on the characteristics of a minitype neutron reference radiation field
topic Neutron reference radiation field
Minitype
Instrument response
Neutron fluence
Neutron energy spectra
url http://www.sciencedirect.com/science/article/pii/S2211379723010872
work_keys_str_mv AT songzhang simulationresearchonthecharacteristicsofaminitypeneutronreferenceradiationfield
AT yikunqian simulationresearchonthecharacteristicsofaminitypeneutronreferenceradiationfield
AT yuchenhuang simulationresearchonthecharacteristicsofaminitypeneutronreferenceradiationfield
AT penghe simulationresearchonthecharacteristicsofaminitypeneutronreferenceradiationfield
AT pengfeng simulationresearchonthecharacteristicsofaminitypeneutronreferenceradiationfield