Сomparison of biomechanical properties of non-absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse: experimental study
Introduction. The amount of non-absorbable synthetic material used in the surgical treatment of pelvic organ prolapse and stress urinary incontinence has been shown to directly correlate with the risks of mesh-associated complications. Previously, we developed a partially absorbable implant. Current...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
State Budget Educational Institute of Higher Professional Education, Rostov State Medical University, Ministry Health of Russian Federation
2023-04-01
|
Series: | Vestnik Urologii |
Subjects: | |
Online Access: | https://www.urovest.ru/jour/article/view/676 |
_version_ | 1797272068999348224 |
---|---|
author | D. D. Shkarupa R. A. Shakhaliev A. S. Shulgin T. S. Filipenko N. D. Kubin I. A. Labetov D. A. Suchkov |
author_facet | D. D. Shkarupa R. A. Shakhaliev A. S. Shulgin T. S. Filipenko N. D. Kubin I. A. Labetov D. A. Suchkov |
author_sort | D. D. Shkarupa |
collection | DOAJ |
description | Introduction. The amount of non-absorbable synthetic material used in the surgical treatment of pelvic organ prolapse and stress urinary incontinence has been shown to directly correlate with the risks of mesh-associated complications. Previously, we developed a partially absorbable implant. Currently, there are insufficient data on the use of partially absorbable implants in female pelvic floor reconstruction, which requires comparative biomechanical and pathomorphological studies.Objective. To compare the biomechanical properties of a new generation partially absorbable implants and nonabsorbable polypropylene mesh implants during animal model.Materials & methods. Thirty-nine rabbits weighing 3200 ± 250 g were randomised into three groups depending on the implanted endoprosthesis: group 1 (n = 15) — “Axilen” implant (polydioxanone 98%, polypropylene 2%), group 2 (n = 15) — “Axilen Rapid” implant (polyglycapron 98%, polypropylene 2%), group 3 (n = 9) — “Urosling 1” implant. After implantation, rabbits of all 3 groups were divided into 3 subgroups according to the withdrawal period from the experiment: 14 days, 60 days, and 180 days. The biomaterial obtained was subjected to two studies: evaluation of the macroscopic view of the explanted mesh endoprosthesis with the formed capsule and the surrounding tissues, study of the biomechanical properties of the formed connective tissue capsule with the implant.Results. According to macroscopic evaluation, there was a less significant tissue reaction to partially absorbed implants. A comparative analysis of biomechanical indices revealed no statistically significant difference in rupture elongation at all follow-up periods among the presented groups. Tensile strength, at 60 and 180 days, was not statistically different between the groups described. At 14 days, there was a statistically significant difference in tensile strength between groups 1 and 3 (p = 0.003).Conclusion. During biomechanical animal experiments, the connective tissue capsule formed on the partially absorbable implant was not inferior to the similar parameter of the non-absorbable sample in its tensile strength, which explains a great potential for the use of partially absorbable implants in reconstructive surgery of pelvic organ prolapse and stress urinary incontinence. |
first_indexed | 2024-03-07T14:23:06Z |
format | Article |
id | doaj.art-3d4d1d91d5b6434d8b763ea9b879aeb7 |
institution | Directory Open Access Journal |
issn | 2308-6424 |
language | Russian |
last_indexed | 2024-03-07T14:23:06Z |
publishDate | 2023-04-01 |
publisher | State Budget Educational Institute of Higher Professional Education, Rostov State Medical University, Ministry Health of Russian Federation |
record_format | Article |
series | Vestnik Urologii |
spelling | doaj.art-3d4d1d91d5b6434d8b763ea9b879aeb72024-03-06T08:56:06ZrusState Budget Educational Institute of Higher Professional Education, Rostov State Medical University, Ministry Health of Russian FederationVestnik Urologii2308-64242023-04-0111111612410.21886/2308-6424-2023-11-1-116-124427Сomparison of biomechanical properties of non-absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse: experimental studyD. D. Shkarupa0R. A. Shakhaliev1A. S. Shulgin2T. S. Filipenko3N. D. Kubin4I. A. Labetov5D. A. Suchkov6Pirogov Clinic of Advanced Medical Technologies (SPSU Hospital) — St. Petersburg State UniversityPirogov Clinic of Advanced Medical Technologies (SPSU Hospital) — St. Petersburg State UniversityPirogov Clinic of Advanced Medical Technologies (SPSU Hospital) — St. Petersburg State University«Lintex» LLCPirogov Clinic of Advanced Medical Technologies (SPSU Hospital) — St. Petersburg State UniversityPirogov Clinic of Advanced Medical Technologies (SPSU Hospital) — St. Petersburg State UniversityPirogov Clinic of Advanced Medical Technologies (SPSU Hospital) — St. Petersburg State UniversityIntroduction. The amount of non-absorbable synthetic material used in the surgical treatment of pelvic organ prolapse and stress urinary incontinence has been shown to directly correlate with the risks of mesh-associated complications. Previously, we developed a partially absorbable implant. Currently, there are insufficient data on the use of partially absorbable implants in female pelvic floor reconstruction, which requires comparative biomechanical and pathomorphological studies.Objective. To compare the biomechanical properties of a new generation partially absorbable implants and nonabsorbable polypropylene mesh implants during animal model.Materials & methods. Thirty-nine rabbits weighing 3200 ± 250 g were randomised into three groups depending on the implanted endoprosthesis: group 1 (n = 15) — “Axilen” implant (polydioxanone 98%, polypropylene 2%), group 2 (n = 15) — “Axilen Rapid” implant (polyglycapron 98%, polypropylene 2%), group 3 (n = 9) — “Urosling 1” implant. After implantation, rabbits of all 3 groups were divided into 3 subgroups according to the withdrawal period from the experiment: 14 days, 60 days, and 180 days. The biomaterial obtained was subjected to two studies: evaluation of the macroscopic view of the explanted mesh endoprosthesis with the formed capsule and the surrounding tissues, study of the biomechanical properties of the formed connective tissue capsule with the implant.Results. According to macroscopic evaluation, there was a less significant tissue reaction to partially absorbed implants. A comparative analysis of biomechanical indices revealed no statistically significant difference in rupture elongation at all follow-up periods among the presented groups. Tensile strength, at 60 and 180 days, was not statistically different between the groups described. At 14 days, there was a statistically significant difference in tensile strength between groups 1 and 3 (p = 0.003).Conclusion. During biomechanical animal experiments, the connective tissue capsule formed on the partially absorbable implant was not inferior to the similar parameter of the non-absorbable sample in its tensile strength, which explains a great potential for the use of partially absorbable implants in reconstructive surgery of pelvic organ prolapse and stress urinary incontinence.https://www.urovest.ru/jour/article/view/676pelvic organ prolapsestress urinary incontinencemesh |
spellingShingle | D. D. Shkarupa R. A. Shakhaliev A. S. Shulgin T. S. Filipenko N. D. Kubin I. A. Labetov D. A. Suchkov Сomparison of biomechanical properties of non-absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse: experimental study Vestnik Urologii pelvic organ prolapse stress urinary incontinence mesh |
title | Сomparison of biomechanical properties of non-absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse: experimental study |
title_full | Сomparison of biomechanical properties of non-absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse: experimental study |
title_fullStr | Сomparison of biomechanical properties of non-absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse: experimental study |
title_full_unstemmed | Сomparison of biomechanical properties of non-absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse: experimental study |
title_short | Сomparison of biomechanical properties of non-absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse: experimental study |
title_sort | сomparison of biomechanical properties of non absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse experimental study |
topic | pelvic organ prolapse stress urinary incontinence mesh |
url | https://www.urovest.ru/jour/article/view/676 |
work_keys_str_mv | AT ddshkarupa somparisonofbiomechanicalpropertiesofnonabsorbableandpartiallyabsorbablemeshimplantsusedinsurgeryforurinaryincontinenceandgenitalprolapseexperimentalstudy AT rashakhaliev somparisonofbiomechanicalpropertiesofnonabsorbableandpartiallyabsorbablemeshimplantsusedinsurgeryforurinaryincontinenceandgenitalprolapseexperimentalstudy AT asshulgin somparisonofbiomechanicalpropertiesofnonabsorbableandpartiallyabsorbablemeshimplantsusedinsurgeryforurinaryincontinenceandgenitalprolapseexperimentalstudy AT tsfilipenko somparisonofbiomechanicalpropertiesofnonabsorbableandpartiallyabsorbablemeshimplantsusedinsurgeryforurinaryincontinenceandgenitalprolapseexperimentalstudy AT ndkubin somparisonofbiomechanicalpropertiesofnonabsorbableandpartiallyabsorbablemeshimplantsusedinsurgeryforurinaryincontinenceandgenitalprolapseexperimentalstudy AT ialabetov somparisonofbiomechanicalpropertiesofnonabsorbableandpartiallyabsorbablemeshimplantsusedinsurgeryforurinaryincontinenceandgenitalprolapseexperimentalstudy AT dasuchkov somparisonofbiomechanicalpropertiesofnonabsorbableandpartiallyabsorbablemeshimplantsusedinsurgeryforurinaryincontinenceandgenitalprolapseexperimentalstudy |