Traction Transformer 1 MV.A, Superconducting, Oil-immersed and Medium Frequency
This paper deals with comparing 3 types of transformers - superconducting, oil-immersed and middle-frequency. These transformers can be used for locomotive as the main transformer. Weight, sizes and losses are introduced. The influence of eddy currents is describes by middle-frequency transformer. T...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
VSB-Technical University of Ostrava
2008-01-01
|
Series: | Advances in Electrical and Electronic Engineering |
Subjects: | |
Online Access: | http://advances.utc.sk/index.php/AEEE/article/view/134 |
_version_ | 1797827176266989568 |
---|---|
author | Milan Krasl Roman Pechanek Rostislav Vlk |
author_facet | Milan Krasl Roman Pechanek Rostislav Vlk |
author_sort | Milan Krasl |
collection | DOAJ |
description | This paper deals with comparing 3 types of transformers - superconducting, oil-immersed and middle-frequency. These transformers can be used for locomotive as the main transformer. Weight, sizes and losses are introduced. The influence of eddy currents is describes by middle-frequency transformer. The article deals with magnetic properties of<br />materials for higher frequency.<br /> |
first_indexed | 2024-04-09T12:44:03Z |
format | Article |
id | doaj.art-3d81eedf40b14fc5aabae8632d120def |
institution | Directory Open Access Journal |
issn | 1336-1376 1804-3119 |
language | English |
last_indexed | 2024-04-09T12:44:03Z |
publishDate | 2008-01-01 |
publisher | VSB-Technical University of Ostrava |
record_format | Article |
series | Advances in Electrical and Electronic Engineering |
spelling | doaj.art-3d81eedf40b14fc5aabae8632d120def2023-05-14T20:50:04ZengVSB-Technical University of OstravaAdvances in Electrical and Electronic Engineering1336-13761804-31192008-01-0171 - 219119497Traction Transformer 1 MV.A, Superconducting, Oil-immersed and Medium FrequencyMilan KraslRoman PechanekRostislav VlkThis paper deals with comparing 3 types of transformers - superconducting, oil-immersed and middle-frequency. These transformers can be used for locomotive as the main transformer. Weight, sizes and losses are introduced. The influence of eddy currents is describes by middle-frequency transformer. The article deals with magnetic properties of<br />materials for higher frequency.<br />http://advances.utc.sk/index.php/AEEE/article/view/134transformerssuperconductingoil-immersedmiddle-frequency. |
spellingShingle | Milan Krasl Roman Pechanek Rostislav Vlk Traction Transformer 1 MV.A, Superconducting, Oil-immersed and Medium Frequency Advances in Electrical and Electronic Engineering transformers superconducting oil-immersed middle-frequency. |
title | Traction Transformer 1 MV.A, Superconducting, Oil-immersed and Medium Frequency |
title_full | Traction Transformer 1 MV.A, Superconducting, Oil-immersed and Medium Frequency |
title_fullStr | Traction Transformer 1 MV.A, Superconducting, Oil-immersed and Medium Frequency |
title_full_unstemmed | Traction Transformer 1 MV.A, Superconducting, Oil-immersed and Medium Frequency |
title_short | Traction Transformer 1 MV.A, Superconducting, Oil-immersed and Medium Frequency |
title_sort | traction transformer 1 mv a superconducting oil immersed and medium frequency |
topic | transformers superconducting oil-immersed middle-frequency. |
url | http://advances.utc.sk/index.php/AEEE/article/view/134 |
work_keys_str_mv | AT milankrasl tractiontransformer1mvasuperconductingoilimmersedandmediumfrequency AT romanpechanek tractiontransformer1mvasuperconductingoilimmersedandmediumfrequency AT rostislavvlk tractiontransformer1mvasuperconductingoilimmersedandmediumfrequency |