Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling step

Near-fault ground motions with long-period pulses have been identified as being critical in the design of structures. These motions, which have caused severe damage in recent disastrous earthquakes, are characterized by a short-duration impulsive motion that transmits large amounts of energy into th...

Full description

Bibliographic Details
Main Authors: A. Mortezaei, H. R. Ronagh
Format: Article
Language:English
Published: Copernicus Publications 2013-06-01
Series:Natural Hazards and Earth System Sciences
Online Access:http://www.nat-hazards-earth-syst-sci.net/13/1579/2013/nhess-13-1579-2013.pdf
_version_ 1811233937335255040
author A. Mortezaei
H. R. Ronagh
author_facet A. Mortezaei
H. R. Ronagh
author_sort A. Mortezaei
collection DOAJ
description Near-fault ground motions with long-period pulses have been identified as being critical in the design of structures. These motions, which have caused severe damage in recent disastrous earthquakes, are characterized by a short-duration impulsive motion that transmits large amounts of energy into the structures at the beginning of the earthquake. In nearly all of the past near-fault earthquakes, significant higher mode contributions have been evident in building structures near the fault rupture, resulting in the migration of dynamic demands (i.e. drifts) from the lower to the upper stories. Due to this, the static nonlinear pushover analysis (which utilizes a load pattern proportional to the shape of the fundamental mode of vibration) may not produce accurate results when used in the analysis of structures subjected to near-fault ground motions. The objective of this paper is to improve the accuracy of the pushover method in these situations by introducing a new load pattern into the common pushover procedure. Several pushover analyses are performed for six existing reinforced concrete buildings that possess a variety of natural periods. Then, a comparison is made between the pushover analyses' results (with four new load patterns) and those of FEMA (Federal Emergency Management Agency)-356 with reference to nonlinear dynamic time-history analyses. The comparison shows that, generally, the proposed pushover method yields better results than all FEMA-356 pushover analysis procedures for all investigated response quantities and is a closer match to the nonlinear time-history responses. In general, the method is able to reproduce the essential response features providing a reasonable measure of the likely contribution of higher modes in all phases of the response.
first_indexed 2024-04-12T11:28:29Z
format Article
id doaj.art-3db8d27eab844224b70c08b9f23b6587
institution Directory Open Access Journal
issn 1561-8633
1684-9981
language English
last_indexed 2024-04-12T11:28:29Z
publishDate 2013-06-01
publisher Copernicus Publications
record_format Article
series Natural Hazards and Earth System Sciences
spelling doaj.art-3db8d27eab844224b70c08b9f23b65872022-12-22T03:35:08ZengCopernicus PublicationsNatural Hazards and Earth System Sciences1561-86331684-99812013-06-011361579159310.5194/nhess-13-1579-2013Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling stepA. MortezaeiH. R. RonaghNear-fault ground motions with long-period pulses have been identified as being critical in the design of structures. These motions, which have caused severe damage in recent disastrous earthquakes, are characterized by a short-duration impulsive motion that transmits large amounts of energy into the structures at the beginning of the earthquake. In nearly all of the past near-fault earthquakes, significant higher mode contributions have been evident in building structures near the fault rupture, resulting in the migration of dynamic demands (i.e. drifts) from the lower to the upper stories. Due to this, the static nonlinear pushover analysis (which utilizes a load pattern proportional to the shape of the fundamental mode of vibration) may not produce accurate results when used in the analysis of structures subjected to near-fault ground motions. The objective of this paper is to improve the accuracy of the pushover method in these situations by introducing a new load pattern into the common pushover procedure. Several pushover analyses are performed for six existing reinforced concrete buildings that possess a variety of natural periods. Then, a comparison is made between the pushover analyses' results (with four new load patterns) and those of FEMA (Federal Emergency Management Agency)-356 with reference to nonlinear dynamic time-history analyses. The comparison shows that, generally, the proposed pushover method yields better results than all FEMA-356 pushover analysis procedures for all investigated response quantities and is a closer match to the nonlinear time-history responses. In general, the method is able to reproduce the essential response features providing a reasonable measure of the likely contribution of higher modes in all phases of the response.http://www.nat-hazards-earth-syst-sci.net/13/1579/2013/nhess-13-1579-2013.pdf
spellingShingle A. Mortezaei
H. R. Ronagh
Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling step
Natural Hazards and Earth System Sciences
title Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling step
title_full Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling step
title_fullStr Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling step
title_full_unstemmed Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling step
title_short Effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near-fault ground motions having fling step
title_sort effectiveness of modified pushover analysis procedure for the estimation of seismic demands of buildings subjected to near fault ground motions having fling step
url http://www.nat-hazards-earth-syst-sci.net/13/1579/2013/nhess-13-1579-2013.pdf
work_keys_str_mv AT amortezaei effectivenessofmodifiedpushoveranalysisprocedurefortheestimationofseismicdemandsofbuildingssubjectedtonearfaultgroundmotionshavingflingstep
AT hrronagh effectivenessofmodifiedpushoveranalysisprocedurefortheestimationofseismicdemandsofbuildingssubjectedtonearfaultgroundmotionshavingflingstep