Effects of injection mechanism on air-water air lift pump performance
Due to its advantages, the air lift pump has many applications in real life. Therefore, the present study is dealing with the effect of some parameters on the air lift pump performance. The present study is a continuation of a program started years ago by the fluid mechanics group in Faculty of Engi...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2022-10-01
|
Series: | Alexandria Engineering Journal |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1110016822000072 |
_version_ | 1798031258272399360 |
---|---|
author | Sadek Z. Kassab Abdelrahman A. Abdelrazek Eslam R. Lotfy |
author_facet | Sadek Z. Kassab Abdelrahman A. Abdelrazek Eslam R. Lotfy |
author_sort | Sadek Z. Kassab |
collection | DOAJ |
description | Due to its advantages, the air lift pump has many applications in real life. Therefore, the present study is dealing with the effect of some parameters on the air lift pump performance. The present study is a continuation of a program started years ago by the fluid mechanics group in Faculty of Engineering, Alexandria University. Beginning by validating the obtained results of the experiment set-up by comparing these experimental results with international accepted sets of data. After that the present experiments shed some lights on the inlet injection region of the air lift pump due to the significant effect of its initial conditions on the pump efficiency. Thus the study directed towards investigating the effect of some parameters including the inlet restrictor resistance, the injection direction and the injector riser diameter. The upward injection technique shows higher peak efficiency of 34.7% compared to 29.7% and 28.9% for downward and side injection respectively while the larger injector inner diameter shows maximum water capacity of 928 kg/h. compared to 823 kg/h. water mass flow rate for the smaller inner diameter injector. In all the above experimental tests, flow visualization is used extensively giving a good agreement with well recognized flow pattern map. |
first_indexed | 2024-04-11T19:54:38Z |
format | Article |
id | doaj.art-3dd39568839645cba0bf685a6d7399b2 |
institution | Directory Open Access Journal |
issn | 1110-0168 |
language | English |
last_indexed | 2024-04-11T19:54:38Z |
publishDate | 2022-10-01 |
publisher | Elsevier |
record_format | Article |
series | Alexandria Engineering Journal |
spelling | doaj.art-3dd39568839645cba0bf685a6d7399b22022-12-22T04:06:12ZengElsevierAlexandria Engineering Journal1110-01682022-10-01611075417553Effects of injection mechanism on air-water air lift pump performanceSadek Z. Kassab0Abdelrahman A. Abdelrazek1Eslam R. Lotfy2Mechanical Engineering Department, Faculty of Engineering, Alexandria University, 21544 Alexandria, EgyptMechanical Engineering Department, Faculty of Engineering, Alexandria University, 21544 Alexandria, EgyptCorresponding author.; Mechanical Engineering Department, Faculty of Engineering, Alexandria University, 21544 Alexandria, EgyptDue to its advantages, the air lift pump has many applications in real life. Therefore, the present study is dealing with the effect of some parameters on the air lift pump performance. The present study is a continuation of a program started years ago by the fluid mechanics group in Faculty of Engineering, Alexandria University. Beginning by validating the obtained results of the experiment set-up by comparing these experimental results with international accepted sets of data. After that the present experiments shed some lights on the inlet injection region of the air lift pump due to the significant effect of its initial conditions on the pump efficiency. Thus the study directed towards investigating the effect of some parameters including the inlet restrictor resistance, the injection direction and the injector riser diameter. The upward injection technique shows higher peak efficiency of 34.7% compared to 29.7% and 28.9% for downward and side injection respectively while the larger injector inner diameter shows maximum water capacity of 928 kg/h. compared to 823 kg/h. water mass flow rate for the smaller inner diameter injector. In all the above experimental tests, flow visualization is used extensively giving a good agreement with well recognized flow pattern map.http://www.sciencedirect.com/science/article/pii/S1110016822000072Air lift pumpExperimentalFlow regimeInjectionTwo phase flow |
spellingShingle | Sadek Z. Kassab Abdelrahman A. Abdelrazek Eslam R. Lotfy Effects of injection mechanism on air-water air lift pump performance Alexandria Engineering Journal Air lift pump Experimental Flow regime Injection Two phase flow |
title | Effects of injection mechanism on air-water air lift pump performance |
title_full | Effects of injection mechanism on air-water air lift pump performance |
title_fullStr | Effects of injection mechanism on air-water air lift pump performance |
title_full_unstemmed | Effects of injection mechanism on air-water air lift pump performance |
title_short | Effects of injection mechanism on air-water air lift pump performance |
title_sort | effects of injection mechanism on air water air lift pump performance |
topic | Air lift pump Experimental Flow regime Injection Two phase flow |
url | http://www.sciencedirect.com/science/article/pii/S1110016822000072 |
work_keys_str_mv | AT sadekzkassab effectsofinjectionmechanismonairwaterairliftpumpperformance AT abdelrahmanaabdelrazek effectsofinjectionmechanismonairwaterairliftpumpperformance AT eslamrlotfy effectsofinjectionmechanismonairwaterairliftpumpperformance |