Effects of injection mechanism on air-water air lift pump performance

Due to its advantages, the air lift pump has many applications in real life. Therefore, the present study is dealing with the effect of some parameters on the air lift pump performance. The present study is a continuation of a program started years ago by the fluid mechanics group in Faculty of Engi...

Full description

Bibliographic Details
Main Authors: Sadek Z. Kassab, Abdelrahman A. Abdelrazek, Eslam R. Lotfy
Format: Article
Language:English
Published: Elsevier 2022-10-01
Series:Alexandria Engineering Journal
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1110016822000072
_version_ 1798031258272399360
author Sadek Z. Kassab
Abdelrahman A. Abdelrazek
Eslam R. Lotfy
author_facet Sadek Z. Kassab
Abdelrahman A. Abdelrazek
Eslam R. Lotfy
author_sort Sadek Z. Kassab
collection DOAJ
description Due to its advantages, the air lift pump has many applications in real life. Therefore, the present study is dealing with the effect of some parameters on the air lift pump performance. The present study is a continuation of a program started years ago by the fluid mechanics group in Faculty of Engineering, Alexandria University. Beginning by validating the obtained results of the experiment set-up by comparing these experimental results with international accepted sets of data. After that the present experiments shed some lights on the inlet injection region of the air lift pump due to the significant effect of its initial conditions on the pump efficiency. Thus the study directed towards investigating the effect of some parameters including the inlet restrictor resistance, the injection direction and the injector riser diameter. The upward injection technique shows higher peak efficiency of 34.7% compared to 29.7% and 28.9% for downward and side injection respectively while the larger injector inner diameter shows maximum water capacity of 928 kg/h. compared to 823 kg/h. water mass flow rate for the smaller inner diameter injector. In all the above experimental tests, flow visualization is used extensively giving a good agreement with well recognized flow pattern map.
first_indexed 2024-04-11T19:54:38Z
format Article
id doaj.art-3dd39568839645cba0bf685a6d7399b2
institution Directory Open Access Journal
issn 1110-0168
language English
last_indexed 2024-04-11T19:54:38Z
publishDate 2022-10-01
publisher Elsevier
record_format Article
series Alexandria Engineering Journal
spelling doaj.art-3dd39568839645cba0bf685a6d7399b22022-12-22T04:06:12ZengElsevierAlexandria Engineering Journal1110-01682022-10-01611075417553Effects of injection mechanism on air-water air lift pump performanceSadek Z. Kassab0Abdelrahman A. Abdelrazek1Eslam R. Lotfy2Mechanical Engineering Department, Faculty of Engineering, Alexandria University, 21544 Alexandria, EgyptMechanical Engineering Department, Faculty of Engineering, Alexandria University, 21544 Alexandria, EgyptCorresponding author.; Mechanical Engineering Department, Faculty of Engineering, Alexandria University, 21544 Alexandria, EgyptDue to its advantages, the air lift pump has many applications in real life. Therefore, the present study is dealing with the effect of some parameters on the air lift pump performance. The present study is a continuation of a program started years ago by the fluid mechanics group in Faculty of Engineering, Alexandria University. Beginning by validating the obtained results of the experiment set-up by comparing these experimental results with international accepted sets of data. After that the present experiments shed some lights on the inlet injection region of the air lift pump due to the significant effect of its initial conditions on the pump efficiency. Thus the study directed towards investigating the effect of some parameters including the inlet restrictor resistance, the injection direction and the injector riser diameter. The upward injection technique shows higher peak efficiency of 34.7% compared to 29.7% and 28.9% for downward and side injection respectively while the larger injector inner diameter shows maximum water capacity of 928 kg/h. compared to 823 kg/h. water mass flow rate for the smaller inner diameter injector. In all the above experimental tests, flow visualization is used extensively giving a good agreement with well recognized flow pattern map.http://www.sciencedirect.com/science/article/pii/S1110016822000072Air lift pumpExperimentalFlow regimeInjectionTwo phase flow
spellingShingle Sadek Z. Kassab
Abdelrahman A. Abdelrazek
Eslam R. Lotfy
Effects of injection mechanism on air-water air lift pump performance
Alexandria Engineering Journal
Air lift pump
Experimental
Flow regime
Injection
Two phase flow
title Effects of injection mechanism on air-water air lift pump performance
title_full Effects of injection mechanism on air-water air lift pump performance
title_fullStr Effects of injection mechanism on air-water air lift pump performance
title_full_unstemmed Effects of injection mechanism on air-water air lift pump performance
title_short Effects of injection mechanism on air-water air lift pump performance
title_sort effects of injection mechanism on air water air lift pump performance
topic Air lift pump
Experimental
Flow regime
Injection
Two phase flow
url http://www.sciencedirect.com/science/article/pii/S1110016822000072
work_keys_str_mv AT sadekzkassab effectsofinjectionmechanismonairwaterairliftpumpperformance
AT abdelrahmanaabdelrazek effectsofinjectionmechanismonairwaterairliftpumpperformance
AT eslamrlotfy effectsofinjectionmechanismonairwaterairliftpumpperformance