COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE

The study is based on results of modeling of measurement circuit containing vibrating-plate capacitor using a complex-harmonic analysis technique. Low value of normalized frequency of small-sized scanning Kelvin probe leads to high distortion factor of probe’s measurement signal that in turn leads t...

Full description

Bibliographic Details
Main Authors: A. K. Tyavlovsky, A. L. Zharin
Format: Article
Language:English
Published: Belarusian National Technical University 2015-03-01
Series:Pribory i Metody Izmerenij
Subjects:
Online Access:https://pimi.bntu.by/jour/article/view/36
_version_ 1797874875628519424
author A. K. Tyavlovsky
A. L. Zharin
author_facet A. K. Tyavlovsky
A. L. Zharin
author_sort A. K. Tyavlovsky
collection DOAJ
description The study is based on results of modeling of measurement circuit containing vibrating-plate capacitor using a complex-harmonic analysis technique. Low value of normalized frequency of small-sized scanning Kelvin probe leads to high distortion factor of probe’s measurement signal that in turn leads to high measurement errors. The way to lower measurement errors is to register measurement signal on its second harmonic and to control the probe-to-sample gap by monitoring the ratio between the second and the first harmonics’ amplitudes.
first_indexed 2024-04-10T01:38:56Z
format Article
id doaj.art-3de4796d043246408cbf1612cbfff752
institution Directory Open Access Journal
issn 2220-9506
2414-0473
language English
last_indexed 2024-04-10T01:38:56Z
publishDate 2015-03-01
publisher Belarusian National Technical University
record_format Article
series Pribory i Metody Izmerenij
spelling doaj.art-3de4796d043246408cbf1612cbfff7522023-03-13T09:14:44ZengBelarusian National Technical UniversityPribory i Metody Izmerenij2220-95062414-04732015-03-0102354130COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBEA. K. Tyavlovsky0A. L. Zharin1Белорусский национальный технический университетБелорусский национальный технический университетThe study is based on results of modeling of measurement circuit containing vibrating-plate capacitor using a complex-harmonic analysis technique. Low value of normalized frequency of small-sized scanning Kelvin probe leads to high distortion factor of probe’s measurement signal that in turn leads to high measurement errors. The way to lower measurement errors is to register measurement signal on its second harmonic and to control the probe-to-sample gap by monitoring the ratio between the second and the first harmonics’ amplitudes.https://pimi.bntu.by/jour/article/view/36зонд кельвинадинамический конденсаторкомплексно-гармонический анализгармонические искажения
spellingShingle A. K. Tyavlovsky
A. L. Zharin
COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
Pribory i Metody Izmerenij
зонд кельвина
динамический конденсатор
комплексно-гармонический анализ
гармонические искажения
title COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_full COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_fullStr COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_full_unstemmed COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_short COMPENSATION OF MEASUREMENT ERRORS WHEN REDUCING LINEAR DIMENSIONS OF THE KELVIN PROBE
title_sort compensation of measurement errors when reducing linear dimensions of the kelvin probe
topic зонд кельвина
динамический конденсатор
комплексно-гармонический анализ
гармонические искажения
url https://pimi.bntu.by/jour/article/view/36
work_keys_str_mv AT aktyavlovsky compensationofmeasurementerrorswhenreducinglineardimensionsofthekelvinprobe
AT alzharin compensationofmeasurementerrorswhenreducinglineardimensionsofthekelvinprobe