Trombe Wall System’s Thermal Energy Output Analysis at a Factory Building
Solar energy utilization for covering and offsetting the heating loads of buildings, is a sustainable way to reduce energy consumption (electricity, gas, etc.) for space heating. As such, a Trombe wall technology is a classic passive solar heating system used in buildings, that can be modified and a...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-02-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/16/4/1887 |
_version_ | 1811153851143684096 |
---|---|
author | Aleksejs Prozuments Anatolijs Borodinecs Diana Bajare |
author_facet | Aleksejs Prozuments Anatolijs Borodinecs Diana Bajare |
author_sort | Aleksejs Prozuments |
collection | DOAJ |
description | Solar energy utilization for covering and offsetting the heating loads of buildings, is a sustainable way to reduce energy consumption (electricity, gas, etc.) for space heating. As such, a Trombe wall technology is a classic passive solar heating system used in buildings, that can be modified and applied to cold climate regions. This work presents a case study on a Trombe wall’s application in relation to its thermal energy output for space heating purposes at a factory building in central Latvia. The solar radiation and temperature measurements were carried out throughout the months of June to October. The results show that the examined wall has a monthly energy yield of 120 to 290 kWh, suggesting that Trombe wall systems are applicable as a secondary space heating source in cold climate regions such as northern Europe, however, a number of design and structural aspects have to be thoroughly considered. |
first_indexed | 2024-03-11T08:52:40Z |
format | Article |
id | doaj.art-3e0b4db734a943a0813b6785b55e897b |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-03-11T08:52:40Z |
publishDate | 2023-02-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-3e0b4db734a943a0813b6785b55e897b2023-11-16T20:19:10ZengMDPI AGEnergies1996-10732023-02-01164188710.3390/en16041887Trombe Wall System’s Thermal Energy Output Analysis at a Factory BuildingAleksejs Prozuments0Anatolijs Borodinecs1Diana Bajare2Department of Heat Engineering and Technology, Faculty of Civil Engineering, Riga Technical University, LV-1048 Riga, LatviaDepartment of Heat Engineering and Technology, Faculty of Civil Engineering, Riga Technical University, LV-1048 Riga, LatviaDepartment of Building Materials and Products, Faculty of Civil Engineering, Riga Technical University, LV-1048 Riga, LatviaSolar energy utilization for covering and offsetting the heating loads of buildings, is a sustainable way to reduce energy consumption (electricity, gas, etc.) for space heating. As such, a Trombe wall technology is a classic passive solar heating system used in buildings, that can be modified and applied to cold climate regions. This work presents a case study on a Trombe wall’s application in relation to its thermal energy output for space heating purposes at a factory building in central Latvia. The solar radiation and temperature measurements were carried out throughout the months of June to October. The results show that the examined wall has a monthly energy yield of 120 to 290 kWh, suggesting that Trombe wall systems are applicable as a secondary space heating source in cold climate regions such as northern Europe, however, a number of design and structural aspects have to be thoroughly considered.https://www.mdpi.com/1996-1073/16/4/1887trombe wallenergy efficiencypassive energy systemssolar thermal energyenvironmental awareness |
spellingShingle | Aleksejs Prozuments Anatolijs Borodinecs Diana Bajare Trombe Wall System’s Thermal Energy Output Analysis at a Factory Building Energies trombe wall energy efficiency passive energy systems solar thermal energy environmental awareness |
title | Trombe Wall System’s Thermal Energy Output Analysis at a Factory Building |
title_full | Trombe Wall System’s Thermal Energy Output Analysis at a Factory Building |
title_fullStr | Trombe Wall System’s Thermal Energy Output Analysis at a Factory Building |
title_full_unstemmed | Trombe Wall System’s Thermal Energy Output Analysis at a Factory Building |
title_short | Trombe Wall System’s Thermal Energy Output Analysis at a Factory Building |
title_sort | trombe wall system s thermal energy output analysis at a factory building |
topic | trombe wall energy efficiency passive energy systems solar thermal energy environmental awareness |
url | https://www.mdpi.com/1996-1073/16/4/1887 |
work_keys_str_mv | AT aleksejsprozuments trombewallsystemsthermalenergyoutputanalysisatafactorybuilding AT anatolijsborodinecs trombewallsystemsthermalenergyoutputanalysisatafactorybuilding AT dianabajare trombewallsystemsthermalenergyoutputanalysisatafactorybuilding |