Analysis of the Combined Ice Storage (PCM) Heating System Installation with Special Kind of Solar Absorber in an Older House

The energy storage field is nowadays a highly ranking topic. This research deals with the installation and analysis of the ice storage system which combines heat pump, solar absorber, and ice storage tank (phase change material—PCM). This system uses a special kind of solar absorber – header pipes (...

Full description

Bibliographic Details
Main Authors: Peter Sivák, Peter Tauš, Radim Rybár, Martin Beer, Zuzana Šimková, František Baník, Sergey Zhironkin, Jana Čitbajová
Format: Article
Language:English
Published: MDPI AG 2020-07-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/15/3878
_version_ 1797560910569537536
author Peter Sivák
Peter Tauš
Radim Rybár
Martin Beer
Zuzana Šimková
František Baník
Sergey Zhironkin
Jana Čitbajová
author_facet Peter Sivák
Peter Tauš
Radim Rybár
Martin Beer
Zuzana Šimková
František Baník
Sergey Zhironkin
Jana Čitbajová
author_sort Peter Sivák
collection DOAJ
description The energy storage field is nowadays a highly ranking topic. This research deals with the installation and analysis of the ice storage system which combines heat pump, solar absorber, and ice storage tank (phase change material—PCM). This system uses a special kind of solar absorber – header pipes (HDP), which have no thermal isolation compared to the common solar absorber. Thanks to that the HDP, pipes can absorb thermal energy not only from the sun but also from the environment. The rain or snow also affects heat exchange. All that is provided by one technical device. The system can store thermal energy gained from the solar absorber into the ice storage tank for future usage. Research works with data from the real operation, for a period of the year covering all working phases/modes of the system. The analysis of the data led to the identification of several specific modes of the system, especially from the processes taking place in the PCM storage tank during its charging and discharging at various time stages of operation of the whole system. The installation and analysis of the ice storage system probably took place for the first time in Slovakia and Slovak Republic’s conditions. Besides, this system was not installed on a new low-energy house, but on an older family house with thermal insulation. The aim of this installation was also to demonstrate the usability of the ice storage system in an older house and potentially reduce the homeowner’s fees thanks to new technology with higher efficiency. We managed to comprehensively analyze and describe the operation of this system, which also appears to be highly efficient even in a family house with a lower energy certificate, than today’s new low-energy buildings. The results showed a significant efficiency difference in favor of the ice storage system compared to conventional heating systems. The total analysis time was 1616 h and the total efficiency of this heating system—the seasonal coefficient of performance (SCOP) was 4.4. Compared to the average SCOP 3.0 of conventional heating systems for new low-energy houses, the total efficiency increased by 46.6%. These results could therefore be considered as beneficial, especially if we take into account that this system was installed on an approximately 40-year-old family house. The analyzed ice storage system is still working today. The main goals of this paper were to describe the heat pump’s duty cycle with ice storage (PCM) based on real-life data and bring a detailed description of the heat transfer medium behavior at various phases of storing/utilizing heat in the vertical ice storage’s profile for increasing efficiency.
first_indexed 2024-03-10T18:06:52Z
format Article
id doaj.art-3ed226fae21c46d0beffaf1efcdbaf99
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T18:06:52Z
publishDate 2020-07-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-3ed226fae21c46d0beffaf1efcdbaf992023-11-20T08:24:50ZengMDPI AGEnergies1996-10732020-07-011315387810.3390/en13153878Analysis of the Combined Ice Storage (PCM) Heating System Installation with Special Kind of Solar Absorber in an Older HousePeter Sivák0Peter Tauš1Radim Rybár2Martin Beer3Zuzana Šimková4František Baník5Sergey Zhironkin6Jana Čitbajová7Faculty of Mining, Ecology, Process Technologies and Geotechnology, Institute of Earth Sources, Technical University of Košice, Letná 9, 042 00 Košice, SlovakiaFaculty of Mining, Ecology, Process Technologies and Geotechnology, Institute of Earth Sources, Technical University of Košice, Letná 9, 042 00 Košice, SlovakiaFaculty of Mining, Ecology, Process Technologies and Geotechnology, Institute of Earth Sources, Technical University of Košice, Letná 9, 042 00 Košice, SlovakiaFaculty of Mining, Ecology, Process Technologies and Geotechnology, Institute of Earth Sources, Technical University of Košice, Letná 9, 042 00 Košice, SlovakiaFaculty of Mining, Ecology, Process Technologies and Geotechnology, Institute of Earth Sources, Technical University of Košice, Letná 9, 042 00 Košice, SlovakiaDepartment of Electrical Engineering and Mechatronics, Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 042 00 Košice, SlovakiaInstitute of Trade and Economy, Siberian Federal University, 79 Svobodny av., 660041 Krasnoyarsk, RussiaFaculty of Mining, Ecology, Process Technologies and Geotechnology, Institute of Earth Sources, Technical University of Košice, Letná 9, 042 00 Košice, SlovakiaThe energy storage field is nowadays a highly ranking topic. This research deals with the installation and analysis of the ice storage system which combines heat pump, solar absorber, and ice storage tank (phase change material—PCM). This system uses a special kind of solar absorber – header pipes (HDP), which have no thermal isolation compared to the common solar absorber. Thanks to that the HDP, pipes can absorb thermal energy not only from the sun but also from the environment. The rain or snow also affects heat exchange. All that is provided by one technical device. The system can store thermal energy gained from the solar absorber into the ice storage tank for future usage. Research works with data from the real operation, for a period of the year covering all working phases/modes of the system. The analysis of the data led to the identification of several specific modes of the system, especially from the processes taking place in the PCM storage tank during its charging and discharging at various time stages of operation of the whole system. The installation and analysis of the ice storage system probably took place for the first time in Slovakia and Slovak Republic’s conditions. Besides, this system was not installed on a new low-energy house, but on an older family house with thermal insulation. The aim of this installation was also to demonstrate the usability of the ice storage system in an older house and potentially reduce the homeowner’s fees thanks to new technology with higher efficiency. We managed to comprehensively analyze and describe the operation of this system, which also appears to be highly efficient even in a family house with a lower energy certificate, than today’s new low-energy buildings. The results showed a significant efficiency difference in favor of the ice storage system compared to conventional heating systems. The total analysis time was 1616 h and the total efficiency of this heating system—the seasonal coefficient of performance (SCOP) was 4.4. Compared to the average SCOP 3.0 of conventional heating systems for new low-energy houses, the total efficiency increased by 46.6%. These results could therefore be considered as beneficial, especially if we take into account that this system was installed on an approximately 40-year-old family house. The analyzed ice storage system is still working today. The main goals of this paper were to describe the heat pump’s duty cycle with ice storage (PCM) based on real-life data and bring a detailed description of the heat transfer medium behavior at various phases of storing/utilizing heat in the vertical ice storage’s profile for increasing efficiency.https://www.mdpi.com/1996-1073/13/15/3878ice storage systemphase change materialsthermal energy storagerenewable energy sourcesheat energy accumulatorenergy efficiency
spellingShingle Peter Sivák
Peter Tauš
Radim Rybár
Martin Beer
Zuzana Šimková
František Baník
Sergey Zhironkin
Jana Čitbajová
Analysis of the Combined Ice Storage (PCM) Heating System Installation with Special Kind of Solar Absorber in an Older House
Energies
ice storage system
phase change materials
thermal energy storage
renewable energy sources
heat energy accumulator
energy efficiency
title Analysis of the Combined Ice Storage (PCM) Heating System Installation with Special Kind of Solar Absorber in an Older House
title_full Analysis of the Combined Ice Storage (PCM) Heating System Installation with Special Kind of Solar Absorber in an Older House
title_fullStr Analysis of the Combined Ice Storage (PCM) Heating System Installation with Special Kind of Solar Absorber in an Older House
title_full_unstemmed Analysis of the Combined Ice Storage (PCM) Heating System Installation with Special Kind of Solar Absorber in an Older House
title_short Analysis of the Combined Ice Storage (PCM) Heating System Installation with Special Kind of Solar Absorber in an Older House
title_sort analysis of the combined ice storage pcm heating system installation with special kind of solar absorber in an older house
topic ice storage system
phase change materials
thermal energy storage
renewable energy sources
heat energy accumulator
energy efficiency
url https://www.mdpi.com/1996-1073/13/15/3878
work_keys_str_mv AT petersivak analysisofthecombinedicestoragepcmheatingsysteminstallationwithspecialkindofsolarabsorberinanolderhouse
AT petertaus analysisofthecombinedicestoragepcmheatingsysteminstallationwithspecialkindofsolarabsorberinanolderhouse
AT radimrybar analysisofthecombinedicestoragepcmheatingsysteminstallationwithspecialkindofsolarabsorberinanolderhouse
AT martinbeer analysisofthecombinedicestoragepcmheatingsysteminstallationwithspecialkindofsolarabsorberinanolderhouse
AT zuzanasimkova analysisofthecombinedicestoragepcmheatingsysteminstallationwithspecialkindofsolarabsorberinanolderhouse
AT frantisekbanik analysisofthecombinedicestoragepcmheatingsysteminstallationwithspecialkindofsolarabsorberinanolderhouse
AT sergeyzhironkin analysisofthecombinedicestoragepcmheatingsysteminstallationwithspecialkindofsolarabsorberinanolderhouse
AT janacitbajova analysisofthecombinedicestoragepcmheatingsysteminstallationwithspecialkindofsolarabsorberinanolderhouse