Development of Infusion Device Analyzer Equipped with Occlusion Detection and a Real-Time Parameters Monitoring on Computer System

Medical infusion device provides drugs or fluids directly through a blood vessel. However, the occurrence of occlusion in the infusion device causes the incoming drug fluid does not to flow constantly, and pressure is formed on the infusion tube. When an infusion device has been used for a long time...

Full description

Bibliographic Details
Main Authors: Anita Miftahul Maghfiroh, Nina Havilda, Sima Das
Format: Article
Language:English
Published: Poltekkes Kemenkes Surabaya 2022-03-01
Series:Jurnal Teknokes
Subjects:
Online Access:http://teknokes.poltekkesdepkes-sby.ac.id/index.php/Teknokes/article/view/192
_version_ 1797974546415878144
author Anita Miftahul Maghfiroh
Nina Havilda
Sima Das
author_facet Anita Miftahul Maghfiroh
Nina Havilda
Sima Das
author_sort Anita Miftahul Maghfiroh
collection DOAJ
description Medical infusion device provides drugs or fluids directly through a blood vessel. However, the occurrence of occlusion in the infusion device causes the incoming drug fluid does not to flow constantly, and pressure is formed on the infusion tube. When an infusion device has been used for a long time, there will be a change in the precision of the flow and pressure values. Furthermore, a calibration process must be carried out at least once a year. This research aims to design an infusion device analyzer which able to show parameters in a graphic equipped with occlusion parameters and Bluetooth communication in real-time to the computer unit. This study uses a solenoid valve for pressure simulation. The allowable occlusion limit is <20 Psi. The SKU 237545 sensor detects the water pressure that is blocked by the solenoid valve. Then the data will be displayed on the Parallax data acquisitions using Bluetooth communication. The Parallax data acquisitions will display real-time occlusion data, data averages, instant values, and graphs. The results of the IDA design, when tested using the Syringe Pump TOP 5300, obtained an average of 0.68 Psi. Meanwhile, when the IDA design was tested using the Infusion Pump 3300, it brought 0.73 Psi. Furthermore, it showed that the occlusion parameter was compared with the Fluke IDA 4, a mean error was 0.7 Psi. Therefore, it can be concluded that this IDA design can be used for calibration to see the feasibility of an infusion pump or syringe pump.
first_indexed 2024-04-11T04:21:29Z
format Article
id doaj.art-3ed9e38dc6514cfc84b3b80a9f98e6a5
institution Directory Open Access Journal
issn 2407-8964
language English
last_indexed 2024-04-11T04:21:29Z
publishDate 2022-03-01
publisher Poltekkes Kemenkes Surabaya
record_format Article
series Jurnal Teknokes
spelling doaj.art-3ed9e38dc6514cfc84b3b80a9f98e6a52022-12-30T14:06:13ZengPoltekkes Kemenkes SurabayaJurnal Teknokes2407-89642022-03-01151212710.35882/teknokes.v15i1.4192Development of Infusion Device Analyzer Equipped with Occlusion Detection and a Real-Time Parameters Monitoring on Computer SystemAnita Miftahul Maghfiroh0Nina Havilda1Sima Das2Department of Electromedical Engineering, Poltekkes Kemenkes SurabayaDepartment of Electromedical Engineering, Poltekkes Kemenkes SurabayaCamellia Institute of Technology and Management, Hooghly, IndiaMedical infusion device provides drugs or fluids directly through a blood vessel. However, the occurrence of occlusion in the infusion device causes the incoming drug fluid does not to flow constantly, and pressure is formed on the infusion tube. When an infusion device has been used for a long time, there will be a change in the precision of the flow and pressure values. Furthermore, a calibration process must be carried out at least once a year. This research aims to design an infusion device analyzer which able to show parameters in a graphic equipped with occlusion parameters and Bluetooth communication in real-time to the computer unit. This study uses a solenoid valve for pressure simulation. The allowable occlusion limit is <20 Psi. The SKU 237545 sensor detects the water pressure that is blocked by the solenoid valve. Then the data will be displayed on the Parallax data acquisitions using Bluetooth communication. The Parallax data acquisitions will display real-time occlusion data, data averages, instant values, and graphs. The results of the IDA design, when tested using the Syringe Pump TOP 5300, obtained an average of 0.68 Psi. Meanwhile, when the IDA design was tested using the Infusion Pump 3300, it brought 0.73 Psi. Furthermore, it showed that the occlusion parameter was compared with the Fluke IDA 4, a mean error was 0.7 Psi. Therefore, it can be concluded that this IDA design can be used for calibration to see the feasibility of an infusion pump or syringe pump.http://teknokes.poltekkesdepkes-sby.ac.id/index.php/Teknokes/article/view/192bluetooth, calibration, occlusion, plx daqida
spellingShingle Anita Miftahul Maghfiroh
Nina Havilda
Sima Das
Development of Infusion Device Analyzer Equipped with Occlusion Detection and a Real-Time Parameters Monitoring on Computer System
Jurnal Teknokes
bluetooth, calibration, occlusion, plx daq
ida
title Development of Infusion Device Analyzer Equipped with Occlusion Detection and a Real-Time Parameters Monitoring on Computer System
title_full Development of Infusion Device Analyzer Equipped with Occlusion Detection and a Real-Time Parameters Monitoring on Computer System
title_fullStr Development of Infusion Device Analyzer Equipped with Occlusion Detection and a Real-Time Parameters Monitoring on Computer System
title_full_unstemmed Development of Infusion Device Analyzer Equipped with Occlusion Detection and a Real-Time Parameters Monitoring on Computer System
title_short Development of Infusion Device Analyzer Equipped with Occlusion Detection and a Real-Time Parameters Monitoring on Computer System
title_sort development of infusion device analyzer equipped with occlusion detection and a real time parameters monitoring on computer system
topic bluetooth, calibration, occlusion, plx daq
ida
url http://teknokes.poltekkesdepkes-sby.ac.id/index.php/Teknokes/article/view/192
work_keys_str_mv AT anitamiftahulmaghfiroh developmentofinfusiondeviceanalyzerequippedwithocclusiondetectionandarealtimeparametersmonitoringoncomputersystem
AT ninahavilda developmentofinfusiondeviceanalyzerequippedwithocclusiondetectionandarealtimeparametersmonitoringoncomputersystem
AT simadas developmentofinfusiondeviceanalyzerequippedwithocclusiondetectionandarealtimeparametersmonitoringoncomputersystem