Brain morphometry in older adults with and without dementia using extremely rapid structural scans

T1-weighted structural MRI is widely used to measure brain morphometry (e.g., cortical thickness and subcortical volumes). Accelerated scans as fast as one minute or less are now available but it is unclear if they are adequate for quantitative morphometry. Here we compared the measurement propertie...

Full description

Bibliographic Details
Main Authors: Maxwell L. Elliott, Lindsay C. Hanford, Aya Hamadeh, Tom Hilbert, Tobias Kober, Bradford C. Dickerson, Ross W. Mair, Mark C. Eldaief, Randy L. Buckner
Format: Article
Language:English
Published: Elsevier 2023-08-01
Series:NeuroImage
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1053811923003245
_version_ 1797799068330622976
author Maxwell L. Elliott
Lindsay C. Hanford
Aya Hamadeh
Tom Hilbert
Tobias Kober
Bradford C. Dickerson
Ross W. Mair
Mark C. Eldaief
Randy L. Buckner
author_facet Maxwell L. Elliott
Lindsay C. Hanford
Aya Hamadeh
Tom Hilbert
Tobias Kober
Bradford C. Dickerson
Ross W. Mair
Mark C. Eldaief
Randy L. Buckner
author_sort Maxwell L. Elliott
collection DOAJ
description T1-weighted structural MRI is widely used to measure brain morphometry (e.g., cortical thickness and subcortical volumes). Accelerated scans as fast as one minute or less are now available but it is unclear if they are adequate for quantitative morphometry. Here we compared the measurement properties of a widely adopted 1.0 mm resolution scan from the Alzheimer's Disease Neuroimaging Initiative (ADNI = 5′12’’) with two variants of highly accelerated 1.0 mm scans (compressed-sensing, CSx6 = 1′12’’; and wave-controlled aliasing in parallel imaging, WAVEx9 = 1′09’’) in a test-retest study of 37 older adults aged 54 to 86 (including 19 individuals diagnosed with a neurodegenerative dementia). Rapid scans produced highly reliable morphometric measures that largely matched the quality of morphometrics derived from the ADNI scan. Regions of lower reliability and relative divergence between ADNI and rapid scan alternatives tended to occur in midline regions and regions with susceptibility-induced artifacts. Critically, the rapid scans yielded morphometric measures similar to the ADNI scan in regions of high atrophy. The results converge to suggest that, for many current uses, extremely rapid scans can replace longer scans. As a final test, we explored the possibility of a 0′49’’ 1.2 mm CSx6 structural scan, which also showed promise. Rapid structural scans may benefit MRI studies by shortening the scan session and reducing cost, minimizing opportunity for movement, creating room for additional scan sequences, and allowing for the repetition of structural scans to increase precision of the estimates.
first_indexed 2024-03-13T04:14:26Z
format Article
id doaj.art-3efc21ee819c4b15a94be275d2364a98
institution Directory Open Access Journal
issn 1095-9572
language English
last_indexed 2024-03-13T04:14:26Z
publishDate 2023-08-01
publisher Elsevier
record_format Article
series NeuroImage
spelling doaj.art-3efc21ee819c4b15a94be275d2364a982023-06-21T06:51:07ZengElsevierNeuroImage1095-95722023-08-01276120173Brain morphometry in older adults with and without dementia using extremely rapid structural scansMaxwell L. Elliott0Lindsay C. Hanford1Aya Hamadeh2Tom Hilbert3Tobias Kober4Bradford C. Dickerson5Ross W. Mair6Mark C. Eldaief7Randy L. Buckner8Department of Psychology, Center for Brain Science, Harvard University, 52 Oxford Street, Northwest Laboratory 280.10, Cambridge, MA 02138, USA; Corresponding author.Department of Psychology, Center for Brain Science, Harvard University, 52 Oxford Street, Northwest Laboratory 280.10, Cambridge, MA 02138, USABaylor College of Medicine, Houston, TX 77030, USAAdvanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland; Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland; LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, SwitzerlandAdvanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland; Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland; LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, SwitzerlandFrontotemporal Disorders Unit, Massachusetts General Hospital, USA; Alzheimer's Disease Research Center, Massachusetts General Hospital, USA; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, USA; Department of Neurology, Massachusetts General Hospital & Harvard Medical School, USA; Department of Psychiatry, Massachusetts General Hospital & Harvard Medical School, Charlestown, MA 02129, USADepartment of Psychology, Center for Brain Science, Harvard University, 52 Oxford Street, Northwest Laboratory 280.10, Cambridge, MA 02138, USA; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, USAFrontotemporal Disorders Unit, Massachusetts General Hospital, USA; Alzheimer's Disease Research Center, Massachusetts General Hospital, USA; Department of Neurology, Massachusetts General Hospital & Harvard Medical School, USA; Department of Psychiatry, Massachusetts General Hospital & Harvard Medical School, Charlestown, MA 02129, USADepartment of Psychology, Center for Brain Science, Harvard University, 52 Oxford Street, Northwest Laboratory 280.10, Cambridge, MA 02138, USA; Alzheimer's Disease Research Center, Massachusetts General Hospital, USA; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, USA; Department of Psychiatry, Massachusetts General Hospital & Harvard Medical School, Charlestown, MA 02129, USAT1-weighted structural MRI is widely used to measure brain morphometry (e.g., cortical thickness and subcortical volumes). Accelerated scans as fast as one minute or less are now available but it is unclear if they are adequate for quantitative morphometry. Here we compared the measurement properties of a widely adopted 1.0 mm resolution scan from the Alzheimer's Disease Neuroimaging Initiative (ADNI = 5′12’’) with two variants of highly accelerated 1.0 mm scans (compressed-sensing, CSx6 = 1′12’’; and wave-controlled aliasing in parallel imaging, WAVEx9 = 1′09’’) in a test-retest study of 37 older adults aged 54 to 86 (including 19 individuals diagnosed with a neurodegenerative dementia). Rapid scans produced highly reliable morphometric measures that largely matched the quality of morphometrics derived from the ADNI scan. Regions of lower reliability and relative divergence between ADNI and rapid scan alternatives tended to occur in midline regions and regions with susceptibility-induced artifacts. Critically, the rapid scans yielded morphometric measures similar to the ADNI scan in regions of high atrophy. The results converge to suggest that, for many current uses, extremely rapid scans can replace longer scans. As a final test, we explored the possibility of a 0′49’’ 1.2 mm CSx6 structural scan, which also showed promise. Rapid structural scans may benefit MRI studies by shortening the scan session and reducing cost, minimizing opportunity for movement, creating room for additional scan sequences, and allowing for the repetition of structural scans to increase precision of the estimates.http://www.sciencedirect.com/science/article/pii/S1053811923003245MRIHippocampusADNIAgingAlzheimer's diseaseFrontotemporal lobar degeneration
spellingShingle Maxwell L. Elliott
Lindsay C. Hanford
Aya Hamadeh
Tom Hilbert
Tobias Kober
Bradford C. Dickerson
Ross W. Mair
Mark C. Eldaief
Randy L. Buckner
Brain morphometry in older adults with and without dementia using extremely rapid structural scans
NeuroImage
MRI
Hippocampus
ADNI
Aging
Alzheimer's disease
Frontotemporal lobar degeneration
title Brain morphometry in older adults with and without dementia using extremely rapid structural scans
title_full Brain morphometry in older adults with and without dementia using extremely rapid structural scans
title_fullStr Brain morphometry in older adults with and without dementia using extremely rapid structural scans
title_full_unstemmed Brain morphometry in older adults with and without dementia using extremely rapid structural scans
title_short Brain morphometry in older adults with and without dementia using extremely rapid structural scans
title_sort brain morphometry in older adults with and without dementia using extremely rapid structural scans
topic MRI
Hippocampus
ADNI
Aging
Alzheimer's disease
Frontotemporal lobar degeneration
url http://www.sciencedirect.com/science/article/pii/S1053811923003245
work_keys_str_mv AT maxwelllelliott brainmorphometryinolderadultswithandwithoutdementiausingextremelyrapidstructuralscans
AT lindsaychanford brainmorphometryinolderadultswithandwithoutdementiausingextremelyrapidstructuralscans
AT ayahamadeh brainmorphometryinolderadultswithandwithoutdementiausingextremelyrapidstructuralscans
AT tomhilbert brainmorphometryinolderadultswithandwithoutdementiausingextremelyrapidstructuralscans
AT tobiaskober brainmorphometryinolderadultswithandwithoutdementiausingextremelyrapidstructuralscans
AT bradfordcdickerson brainmorphometryinolderadultswithandwithoutdementiausingextremelyrapidstructuralscans
AT rosswmair brainmorphometryinolderadultswithandwithoutdementiausingextremelyrapidstructuralscans
AT markceldaief brainmorphometryinolderadultswithandwithoutdementiausingextremelyrapidstructuralscans
AT randylbuckner brainmorphometryinolderadultswithandwithoutdementiausingextremelyrapidstructuralscans