Project-Oriented RF Coil Comparison and Optimization for Preclinical, Single-Voxel MR Spectroscopy of the Rat Visual Cortex at 9.4 T

As one of the most important cortical structures in the brain, the visual cortex plays a primary role in processing visual data. Observing the metabolic changes in this region using single-voxel MR spectroscopy (MRS) can provide a plethora of information on the disease stage and progress in vivo. Fo...

Full description

Bibliographic Details
Main Authors: Chang-Hoon Choi, Ezequiel Farrher, Jorg Felder, Jing Wang, Antje Willuweit, N. Jon Shah
Format: Article
Language:English
Published: IEEE 2023-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/10124212/
_version_ 1797820024001396736
author Chang-Hoon Choi
Ezequiel Farrher
Jorg Felder
Jing Wang
Antje Willuweit
N. Jon Shah
author_facet Chang-Hoon Choi
Ezequiel Farrher
Jorg Felder
Jing Wang
Antje Willuweit
N. Jon Shah
author_sort Chang-Hoon Choi
collection DOAJ
description As one of the most important cortical structures in the brain, the visual cortex plays a primary role in processing visual data. Observing the metabolic changes in this region using single-voxel MR spectroscopy (MRS) can provide a plethora of information on the disease stage and progress in vivo. For single-voxel MRS experiments, a target voxel is always chosen and specifically investigated. The volume of the voxel must be sufficiently small to avoid any interference from adjacent areas but large enough to maximise its signal-to-noise ratio (SNR). Of the factors used to improve SNR, e.g. enlarging voxel size or increasing the number of signal averaging, the optimisation of the RF coil can contribute significantly to the SNR improvement. In this work, we compared and optimised RF coils which include a circularly-polarised (CP) high-pass birdcage coil and two CP surface coils with different dimensions. The coils were particularly designed for the entire rat head, brain and the target region (visual cortex), respectively. The performance of these coils was evaluated based on the project-specific purpose of investigating metabolite concentration changes in the visual cortex of the in vivo rat brain, assessed by means of single-voxel MRS at 9.4 T. In the SNR comparison, the values obtained using the optimised small loop coil were found to be approximately 5 and 1.35 times higher than those using the birdcage volume head coil and the medium-sized loop coil, respectively. In other words, using the optimised coil rather than, for example, the birdcage coil allows the acquisition to be completed more quickly by a factor of 25 times. In conclusion, by using the optimised setup, we can i) benefit either from reduced measurement time or in the acquisition of high-quality MR images or ii) obtain spectra with a minimum quantification error.
first_indexed 2024-03-13T09:32:12Z
format Article
id doaj.art-3f0e19f0eaa6459a8a8501770de0df6e
institution Directory Open Access Journal
issn 2169-3536
language English
last_indexed 2024-03-13T09:32:12Z
publishDate 2023-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj.art-3f0e19f0eaa6459a8a8501770de0df6e2023-05-25T23:00:22ZengIEEEIEEE Access2169-35362023-01-0111486014861010.1109/ACCESS.2023.327623910124212Project-Oriented RF Coil Comparison and Optimization for Preclinical, Single-Voxel MR Spectroscopy of the Rat Visual Cortex at 9.4 TChang-Hoon Choi0https://orcid.org/0000-0003-3569-0905Ezequiel Farrher1https://orcid.org/0000-0003-2902-8667Jorg Felder2https://orcid.org/0000-0001-6431-4322Jing Wang3https://orcid.org/0000-0002-6656-5608Antje Willuweit4N. Jon Shah5https://orcid.org/0000-0002-8151-6169Institute of Neuroscience and Medicine---4, Forschungszentrum Juelich, Juelich, GermanyInstitute of Neuroscience and Medicine---4, Forschungszentrum Juelich, Juelich, GermanyInstitute of Neuroscience and Medicine---4, Forschungszentrum Juelich, Juelich, GermanyInstitute of Neuroscience and Medicine---4, Forschungszentrum Juelich, Juelich, GermanyInstitute of Neuroscience and Medicine---4, Forschungszentrum Juelich, Juelich, GermanyInstitute of Neuroscience and Medicine---4, Forschungszentrum Juelich, Juelich, GermanyAs one of the most important cortical structures in the brain, the visual cortex plays a primary role in processing visual data. Observing the metabolic changes in this region using single-voxel MR spectroscopy (MRS) can provide a plethora of information on the disease stage and progress in vivo. For single-voxel MRS experiments, a target voxel is always chosen and specifically investigated. The volume of the voxel must be sufficiently small to avoid any interference from adjacent areas but large enough to maximise its signal-to-noise ratio (SNR). Of the factors used to improve SNR, e.g. enlarging voxel size or increasing the number of signal averaging, the optimisation of the RF coil can contribute significantly to the SNR improvement. In this work, we compared and optimised RF coils which include a circularly-polarised (CP) high-pass birdcage coil and two CP surface coils with different dimensions. The coils were particularly designed for the entire rat head, brain and the target region (visual cortex), respectively. The performance of these coils was evaluated based on the project-specific purpose of investigating metabolite concentration changes in the visual cortex of the in vivo rat brain, assessed by means of single-voxel MRS at 9.4 T. In the SNR comparison, the values obtained using the optimised small loop coil were found to be approximately 5 and 1.35 times higher than those using the birdcage volume head coil and the medium-sized loop coil, respectively. In other words, using the optimised coil rather than, for example, the birdcage coil allows the acquisition to be completed more quickly by a factor of 25 times. In conclusion, by using the optimised setup, we can i) benefit either from reduced measurement time or in the acquisition of high-quality MR images or ii) obtain spectra with a minimum quantification error.https://ieeexplore.ieee.org/document/10124212/MRIMRSspectroscopycoiloptimizationpreclinical
spellingShingle Chang-Hoon Choi
Ezequiel Farrher
Jorg Felder
Jing Wang
Antje Willuweit
N. Jon Shah
Project-Oriented RF Coil Comparison and Optimization for Preclinical, Single-Voxel MR Spectroscopy of the Rat Visual Cortex at 9.4 T
IEEE Access
MRI
MRS
spectroscopy
coil
optimization
preclinical
title Project-Oriented RF Coil Comparison and Optimization for Preclinical, Single-Voxel MR Spectroscopy of the Rat Visual Cortex at 9.4 T
title_full Project-Oriented RF Coil Comparison and Optimization for Preclinical, Single-Voxel MR Spectroscopy of the Rat Visual Cortex at 9.4 T
title_fullStr Project-Oriented RF Coil Comparison and Optimization for Preclinical, Single-Voxel MR Spectroscopy of the Rat Visual Cortex at 9.4 T
title_full_unstemmed Project-Oriented RF Coil Comparison and Optimization for Preclinical, Single-Voxel MR Spectroscopy of the Rat Visual Cortex at 9.4 T
title_short Project-Oriented RF Coil Comparison and Optimization for Preclinical, Single-Voxel MR Spectroscopy of the Rat Visual Cortex at 9.4 T
title_sort project oriented rf coil comparison and optimization for preclinical single voxel mr spectroscopy of the rat visual cortex at 9 4 t
topic MRI
MRS
spectroscopy
coil
optimization
preclinical
url https://ieeexplore.ieee.org/document/10124212/
work_keys_str_mv AT changhoonchoi projectorientedrfcoilcomparisonandoptimizationforpreclinicalsinglevoxelmrspectroscopyoftheratvisualcortexat94t
AT ezequielfarrher projectorientedrfcoilcomparisonandoptimizationforpreclinicalsinglevoxelmrspectroscopyoftheratvisualcortexat94t
AT jorgfelder projectorientedrfcoilcomparisonandoptimizationforpreclinicalsinglevoxelmrspectroscopyoftheratvisualcortexat94t
AT jingwang projectorientedrfcoilcomparisonandoptimizationforpreclinicalsinglevoxelmrspectroscopyoftheratvisualcortexat94t
AT antjewilluweit projectorientedrfcoilcomparisonandoptimizationforpreclinicalsinglevoxelmrspectroscopyoftheratvisualcortexat94t
AT njonshah projectorientedrfcoilcomparisonandoptimizationforpreclinicalsinglevoxelmrspectroscopyoftheratvisualcortexat94t