Application of Speckle Tracking Echocardiography for Evaluating Ventricular Function after Transcatheter Pulmonary Valve Replacement
Pulmonary regurgitation usually leads to right heart dilatation and eventually right heart dysfunction, which is associated with a poor prognosis. Transcatheter pulmonary valve replacement is a developing treatment for pulmonary valve dysfunction that can take the place of traditional surgery and ma...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-12-01
|
Series: | Diagnostics |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-4418/14/1/88 |
_version_ | 1797358924575277056 |
---|---|
author | Mengmeng Ji Li Zhang Lang Gao Yixia Lin Qing He Mingxing Xie Yuman Li |
author_facet | Mengmeng Ji Li Zhang Lang Gao Yixia Lin Qing He Mingxing Xie Yuman Li |
author_sort | Mengmeng Ji |
collection | DOAJ |
description | Pulmonary regurgitation usually leads to right heart dilatation and eventually right heart dysfunction, which is associated with a poor prognosis. Transcatheter pulmonary valve replacement is a developing treatment for pulmonary valve dysfunction that can take the place of traditional surgery and make up for the shortcomings of a large injury. Echocardiography plays a significant role in assessing ventricular function; however, conventional echocardiographic parameters have several limitations. Speckle tracking echocardiography has been regarded as a more accurate tool for quantifying cardiac function than conventional echocardiography. Therefore, the aim of this review was to summarize the application of speckle tracking echocardiography for evaluating right and left ventricular functions in patients after transcatheter pulmonary valve replacement. |
first_indexed | 2024-03-08T15:09:13Z |
format | Article |
id | doaj.art-3fba1129df554e78bedafb10add07df0 |
institution | Directory Open Access Journal |
issn | 2075-4418 |
language | English |
last_indexed | 2024-03-08T15:09:13Z |
publishDate | 2023-12-01 |
publisher | MDPI AG |
record_format | Article |
series | Diagnostics |
spelling | doaj.art-3fba1129df554e78bedafb10add07df02024-01-10T14:53:56ZengMDPI AGDiagnostics2075-44182023-12-011418810.3390/diagnostics14010088Application of Speckle Tracking Echocardiography for Evaluating Ventricular Function after Transcatheter Pulmonary Valve ReplacementMengmeng Ji0Li Zhang1Lang Gao2Yixia Lin3Qing He4Mingxing Xie5Yuman Li6Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, ChinaDepartment of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, ChinaDepartment of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, ChinaDepartment of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, ChinaDepartment of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, ChinaDepartment of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, ChinaDepartment of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, ChinaPulmonary regurgitation usually leads to right heart dilatation and eventually right heart dysfunction, which is associated with a poor prognosis. Transcatheter pulmonary valve replacement is a developing treatment for pulmonary valve dysfunction that can take the place of traditional surgery and make up for the shortcomings of a large injury. Echocardiography plays a significant role in assessing ventricular function; however, conventional echocardiographic parameters have several limitations. Speckle tracking echocardiography has been regarded as a more accurate tool for quantifying cardiac function than conventional echocardiography. Therefore, the aim of this review was to summarize the application of speckle tracking echocardiography for evaluating right and left ventricular functions in patients after transcatheter pulmonary valve replacement.https://www.mdpi.com/2075-4418/14/1/88speckle tracking echocardiographytranscatheter pulmonary valve replacement |
spellingShingle | Mengmeng Ji Li Zhang Lang Gao Yixia Lin Qing He Mingxing Xie Yuman Li Application of Speckle Tracking Echocardiography for Evaluating Ventricular Function after Transcatheter Pulmonary Valve Replacement Diagnostics speckle tracking echocardiography transcatheter pulmonary valve replacement |
title | Application of Speckle Tracking Echocardiography for Evaluating Ventricular Function after Transcatheter Pulmonary Valve Replacement |
title_full | Application of Speckle Tracking Echocardiography for Evaluating Ventricular Function after Transcatheter Pulmonary Valve Replacement |
title_fullStr | Application of Speckle Tracking Echocardiography for Evaluating Ventricular Function after Transcatheter Pulmonary Valve Replacement |
title_full_unstemmed | Application of Speckle Tracking Echocardiography for Evaluating Ventricular Function after Transcatheter Pulmonary Valve Replacement |
title_short | Application of Speckle Tracking Echocardiography for Evaluating Ventricular Function after Transcatheter Pulmonary Valve Replacement |
title_sort | application of speckle tracking echocardiography for evaluating ventricular function after transcatheter pulmonary valve replacement |
topic | speckle tracking echocardiography transcatheter pulmonary valve replacement |
url | https://www.mdpi.com/2075-4418/14/1/88 |
work_keys_str_mv | AT mengmengji applicationofspeckletrackingechocardiographyforevaluatingventricularfunctionaftertranscatheterpulmonaryvalvereplacement AT lizhang applicationofspeckletrackingechocardiographyforevaluatingventricularfunctionaftertranscatheterpulmonaryvalvereplacement AT langgao applicationofspeckletrackingechocardiographyforevaluatingventricularfunctionaftertranscatheterpulmonaryvalvereplacement AT yixialin applicationofspeckletrackingechocardiographyforevaluatingventricularfunctionaftertranscatheterpulmonaryvalvereplacement AT qinghe applicationofspeckletrackingechocardiographyforevaluatingventricularfunctionaftertranscatheterpulmonaryvalvereplacement AT mingxingxie applicationofspeckletrackingechocardiographyforevaluatingventricularfunctionaftertranscatheterpulmonaryvalvereplacement AT yumanli applicationofspeckletrackingechocardiographyforevaluatingventricularfunctionaftertranscatheterpulmonaryvalvereplacement |