Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity

<p> <b>V.V. Brzheskiy<sup>1</sup>, E.L. Efimova<sup>1</sup>, M.A. Kopylova<sup>1</sup>, P.V. Kocharina<sup>1</sup>, A.A. Primak<sup>1</sup>, V.P. Nikolaenko<sup>2</sup></b> </p> <p> <b><s...

Full description

Bibliographic Details
Main Authors: V.V. Brzheskiy, E.L. Efimova, M.A. Kopylova, P.V. Kocharina, A.A. Primak, V.P. Nikolaenko
Format: Article
Language:Russian
Published: Prime-Media 2021-12-01
Series:РМЖ "Клиническая офтальмология"
Online Access:http://clinopht.com/upload/iblock/9a3/9a3ba293f3f38db12b49fca4fc76f879.pdf
_version_ 1797295002970226688
author V.V. Brzheskiy
E.L. Efimova
M.A. Kopylova
P.V. Kocharina
A.A. Primak
V.P. Nikolaenko
author_facet V.V. Brzheskiy
E.L. Efimova
M.A. Kopylova
P.V. Kocharina
A.A. Primak
V.P. Nikolaenko
author_sort V.V. Brzheskiy
collection DOAJ
description <p> <b>V.V. Brzheskiy<sup>1</sup>, E.L. Efimova<sup>1</sup>, M.A. Kopylova<sup>1</sup>, P.V. Kocharina<sup>1</sup>, A.A. Primak<sup>1</sup>, V.P. Nikolaenko<sup>2</sup></b> </p> <p> <b><sup>1</sup>St. Petersburg State Pediatric Medical University, Saint-Petersburg, Russian Federation</b> </p> <p> <b><sup>2</sup>St. Petersburg State University, Saint-Petersburg, Russian Federation</b> </p> <p> <i><b>Aim</b>: to study the changes in the critical parameters of tear film stability and autorefractometry in patients with mild dry eye syndrome (DES) after instilling artificial tear products of different viscosity.</i> </p> <p> <i><b>Patients and Methods:</b> thirty patients aged 23–70 with mild bilateral DES were examined using the Visionix VX120+Dry Eye multi-diagnostic unit equipped with the TF-Scan to fix and assess tear film stability and tear breakup time (TBUT). The critical refraction and tear film parameters were evaluated by keratometry, corneal topography, TBUT, and tear meniscus height measurements. Next, an artificial tear product was instilled, i.e., group 1 (14 patients, 28 eyes) received a 0.15% sodium hyaluronate-based preparation, and group 2 (16 patients, 32 eyes) received a 0.4% sodium hyaluronate-based preparation. The examination was repeated after 30 sec and 5 min. Controls were seven healthy individuals (14 eyes).</i> </p> <p> <i><b>Results</b>: in DES, breaks in the tear film appeared earlier and affected greater corneal surface area. A "Destabilized tear film area" parameter of the Visionix VX120+Dry Eye contributed significantly to the knowledge of tear film functionality, thereby empowering the diagnostic armamentarium in DES. As early as 30 sec after instillation of both artificial tear preparations, breakup-free time tended to increase, while the area of tear film destabilization tended to reduce. After 5 min, this trend continued to increase, particularly after instilling 0.15% sodium hyaluronate-based preparation. At the same time, changes in keratometry readings (i.e., sphere and cylinder) and astigmatism axis orientation were reported. Corneal refractive power (more in the flattest axis) increased, in particular, after the instillations of 0.15% hyaluronic acid. The range of changes was 0.00–0.75 D for the sphere power, 0.00–0.50 D for the cylinder power, and 0–69 degrees f or astigmatism axis orientation.</i> </p> <p> <i><b>Conclusions</b>: our findings with the Visionix VX120+Dry Eye multi-diagnostic unit demonstrate a significant variation of autorefractometry readings in DES depending on the extent of ocular surface hydration. These phenomena raise questions about the accuracy of autorefractometry readings. Therefore, autorefractometry should be performed after normalizing tear film volume and stability.</i> </p> <p> <i><b>Keywords</b>: dry eye syndrome, Visionix<sup>®</sup>, autorefractometry, tearscopy, the effect of artificial tears on results.</i> </p> <p> <i><b>For citation:</b> Brzheskiy V.V., Efimova E.L., Kopylova M.A. et al. Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity. Russian Journal of Clinical Ophthalmology. 2021;21(4):200–204 (in Russ.). DOI: 10.32364/2311-7729-2021-21-4-200-204.</i> </p> <i><br> </i><br>
first_indexed 2024-03-07T21:40:18Z
format Article
id doaj.art-402d551f8ffd472388afdb83e69703e8
institution Directory Open Access Journal
issn 2311-7729
2619-1571
language Russian
last_indexed 2024-03-07T21:40:18Z
publishDate 2021-12-01
publisher Prime-Media
record_format Article
series РМЖ "Клиническая офтальмология"
spelling doaj.art-402d551f8ffd472388afdb83e69703e82024-02-26T10:12:10ZrusPrime-MediaРМЖ "Клиническая офтальмология"2311-77292619-15712021-12-0121431357Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosityV.V. Brzheskiy0E.L. Efimova1M.A. Kopylova2P.V. Kocharina3A.A. Primak4V.P. Nikolaenko5Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399<p> <b>V.V. Brzheskiy<sup>1</sup>, E.L. Efimova<sup>1</sup>, M.A. Kopylova<sup>1</sup>, P.V. Kocharina<sup>1</sup>, A.A. Primak<sup>1</sup>, V.P. Nikolaenko<sup>2</sup></b> </p> <p> <b><sup>1</sup>St. Petersburg State Pediatric Medical University, Saint-Petersburg, Russian Federation</b> </p> <p> <b><sup>2</sup>St. Petersburg State University, Saint-Petersburg, Russian Federation</b> </p> <p> <i><b>Aim</b>: to study the changes in the critical parameters of tear film stability and autorefractometry in patients with mild dry eye syndrome (DES) after instilling artificial tear products of different viscosity.</i> </p> <p> <i><b>Patients and Methods:</b> thirty patients aged 23–70 with mild bilateral DES were examined using the Visionix VX120+Dry Eye multi-diagnostic unit equipped with the TF-Scan to fix and assess tear film stability and tear breakup time (TBUT). The critical refraction and tear film parameters were evaluated by keratometry, corneal topography, TBUT, and tear meniscus height measurements. Next, an artificial tear product was instilled, i.e., group 1 (14 patients, 28 eyes) received a 0.15% sodium hyaluronate-based preparation, and group 2 (16 patients, 32 eyes) received a 0.4% sodium hyaluronate-based preparation. The examination was repeated after 30 sec and 5 min. Controls were seven healthy individuals (14 eyes).</i> </p> <p> <i><b>Results</b>: in DES, breaks in the tear film appeared earlier and affected greater corneal surface area. A "Destabilized tear film area" parameter of the Visionix VX120+Dry Eye contributed significantly to the knowledge of tear film functionality, thereby empowering the diagnostic armamentarium in DES. As early as 30 sec after instillation of both artificial tear preparations, breakup-free time tended to increase, while the area of tear film destabilization tended to reduce. After 5 min, this trend continued to increase, particularly after instilling 0.15% sodium hyaluronate-based preparation. At the same time, changes in keratometry readings (i.e., sphere and cylinder) and astigmatism axis orientation were reported. Corneal refractive power (more in the flattest axis) increased, in particular, after the instillations of 0.15% hyaluronic acid. The range of changes was 0.00–0.75 D for the sphere power, 0.00–0.50 D for the cylinder power, and 0–69 degrees f or astigmatism axis orientation.</i> </p> <p> <i><b>Conclusions</b>: our findings with the Visionix VX120+Dry Eye multi-diagnostic unit demonstrate a significant variation of autorefractometry readings in DES depending on the extent of ocular surface hydration. These phenomena raise questions about the accuracy of autorefractometry readings. Therefore, autorefractometry should be performed after normalizing tear film volume and stability.</i> </p> <p> <i><b>Keywords</b>: dry eye syndrome, Visionix<sup>®</sup>, autorefractometry, tearscopy, the effect of artificial tears on results.</i> </p> <p> <i><b>For citation:</b> Brzheskiy V.V., Efimova E.L., Kopylova M.A. et al. Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity. Russian Journal of Clinical Ophthalmology. 2021;21(4):200–204 (in Russ.). DOI: 10.32364/2311-7729-2021-21-4-200-204.</i> </p> <i><br> </i><br>http://clinopht.com/upload/iblock/9a3/9a3ba293f3f38db12b49fca4fc76f879.pdf
spellingShingle V.V. Brzheskiy
E.L. Efimova
M.A. Kopylova
P.V. Kocharina
A.A. Primak
V.P. Nikolaenko
Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity
РМЖ "Клиническая офтальмология"
title Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity
title_full Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity
title_fullStr Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity
title_full_unstemmed Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity
title_short Changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity
title_sort changes in the functionality of tear film and autorefractometry reading after instillations of artificial tear products of different viscosity
url http://clinopht.com/upload/iblock/9a3/9a3ba293f3f38db12b49fca4fc76f879.pdf
work_keys_str_mv AT vvbrzheskiy changesinthefunctionalityoftearfilmandautorefractometryreadingafterinstillationsofartificialtearproductsofdifferentviscosity
AT elefimova changesinthefunctionalityoftearfilmandautorefractometryreadingafterinstillationsofartificialtearproductsofdifferentviscosity
AT makopylova changesinthefunctionalityoftearfilmandautorefractometryreadingafterinstillationsofartificialtearproductsofdifferentviscosity
AT pvkocharina changesinthefunctionalityoftearfilmandautorefractometryreadingafterinstillationsofartificialtearproductsofdifferentviscosity
AT aaprimak changesinthefunctionalityoftearfilmandautorefractometryreadingafterinstillationsofartificialtearproductsofdifferentviscosity
AT vpnikolaenko changesinthefunctionalityoftearfilmandautorefractometryreadingafterinstillationsofartificialtearproductsofdifferentviscosity