Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus

Background: The aim of the present study was to investigate the morphologic features and mechanical properties of plantar fascia (PF), flexor hallucis brevis (FHB), flexor digitorum brevis (FDB), and abductor hallucis (AbH) muscles in individuals with halluks valgus (HV) and to compare the results w...

Full description

Bibliographic Details
Main Authors: Serkan Taş, Alp Çetin
Format: Article
Language:English
Published: AVES 2019-07-01
Series:Acta Orthopaedica et Traumatologica Turcica
Online Access:http://www.sciencedirect.com/science/article/pii/S1017995X18303584
_version_ 1828024239063564288
author Serkan Taş
Alp Çetin
author_facet Serkan Taş
Alp Çetin
author_sort Serkan Taş
collection DOAJ
description Background: The aim of the present study was to investigate the morphologic features and mechanical properties of plantar fascia (PF), flexor hallucis brevis (FHB), flexor digitorum brevis (FDB), and abductor hallucis (AbH) muscles in individuals with halluks valgus (HV) and to compare the results with individuals without HV. Methods: A total of 30 participants (27 female, 3 male) between the ages of 19–58 years with HV deformity and 30 individuals without HV (27 female, 3 male) between the ages of 20–58 years were included in the study. AbH, PF, FHB, and FDB thickness, cross-sectional area and stiffness were measured with an ultrasonography device. For stiffness measurements, Shear Wave Velocity (SWV) of the assessed soft tissues was calculated using a customized software program. Results: Mean and standard deviation of SWV of PF, AbH, FHB, FDB, and thickness of PF, AbH, FHB, FDB, and cross-sectional area of AbH, FHB, FDB in individuals with HV were 7.6 ± 1.0 m/sec, 2.8 ± 0.3 m/sec, 2.6 ± 0.4 m/sec, and 3.4 ± 0.2 m/sec, 3.3 ± 0.5 mm, 11.4 ± 2.2 mm, 16.5 ± 1.9 mm, 8.9 ± 1.8 mm, 2.4 ± 0.5 cm2, 2.7 ± 0.5 cm2, 1.9 ± 0.6 cm2, respectively. Mean and standard deviation of SWV of PF, AbH, FHB, FDB and thickness of PF, AbH, FHB, FDB, and cross-sectional area of AbH, FHB, FDB in controls groups were 7.6 ± 1.2 m/sec, 2.3 ± 0.3 m/sec, 2.3 ± 0.4 m/sec, and 3.4 ± 0.4 m/sec, 3.3 ± 0.5 mm, 9.7 ± 2.1 mm, 14.5 ± 1.4 mm, 9.7 ± 1.2 mm, 2.1 ± 0.3 cm2, 2.3 ± 0.4 cm2, 2.1 ± 0.4 cm2, respectively. Individuals with HV had lower AbH and FHB thickness, cross-sectional area and SWV, however FDB thickness and cross-sectional area were higher in individuals with HV compared to that of individuals without HV (p < 0.05). PF thickness (p = 0.273), SWV of PF (p = 0.979) and FDB (p = 0.295) were similar in both groups. Conclusion: Our results suggest that individuals with HV had lower AbH and FHB stiffness, however PF and FDB stiffness were similar in HV and control group. In addition, AbH and FHB thickness and cross-sectional area were lower in individuals with HV; however, FDB thickness and cross-sectional area were higher in individuals with HV compared to that of individuals without HV. Level of Evidence: Level III, Diagnostic Study. Keywords: Hallux valgus, Foot muscles, Stiffness, Muscle size, Ultrasonography, Sonoelestography
first_indexed 2024-04-10T12:41:34Z
format Article
id doaj.art-406e547f4d234d2fa7c9311d02d0d2ac
institution Directory Open Access Journal
issn 1017-995X
language English
last_indexed 2024-04-10T12:41:34Z
publishDate 2019-07-01
publisher AVES
record_format Article
series Acta Orthopaedica et Traumatologica Turcica
spelling doaj.art-406e547f4d234d2fa7c9311d02d0d2ac2023-02-15T16:14:15ZengAVESActa Orthopaedica et Traumatologica Turcica1017-995X2019-07-01534282286Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgusSerkan Taş0Alp Çetin1Toros University, School of Health Sciences, Department of Physiotherapy and Rehabilitation, Mersin, Turkey; Corresponding author. Toros University, School of Health Sciences, Department of Physiotherapy and Rehabilitation, 33140, Mersin, Turkey. Fax: +90 324 325 3301.Hacettepe University, Faculty of Medicine, Department of Physical Medicine and Rehabilitation, Ankara, TurkeyBackground: The aim of the present study was to investigate the morphologic features and mechanical properties of plantar fascia (PF), flexor hallucis brevis (FHB), flexor digitorum brevis (FDB), and abductor hallucis (AbH) muscles in individuals with halluks valgus (HV) and to compare the results with individuals without HV. Methods: A total of 30 participants (27 female, 3 male) between the ages of 19–58 years with HV deformity and 30 individuals without HV (27 female, 3 male) between the ages of 20–58 years were included in the study. AbH, PF, FHB, and FDB thickness, cross-sectional area and stiffness were measured with an ultrasonography device. For stiffness measurements, Shear Wave Velocity (SWV) of the assessed soft tissues was calculated using a customized software program. Results: Mean and standard deviation of SWV of PF, AbH, FHB, FDB, and thickness of PF, AbH, FHB, FDB, and cross-sectional area of AbH, FHB, FDB in individuals with HV were 7.6 ± 1.0 m/sec, 2.8 ± 0.3 m/sec, 2.6 ± 0.4 m/sec, and 3.4 ± 0.2 m/sec, 3.3 ± 0.5 mm, 11.4 ± 2.2 mm, 16.5 ± 1.9 mm, 8.9 ± 1.8 mm, 2.4 ± 0.5 cm2, 2.7 ± 0.5 cm2, 1.9 ± 0.6 cm2, respectively. Mean and standard deviation of SWV of PF, AbH, FHB, FDB and thickness of PF, AbH, FHB, FDB, and cross-sectional area of AbH, FHB, FDB in controls groups were 7.6 ± 1.2 m/sec, 2.3 ± 0.3 m/sec, 2.3 ± 0.4 m/sec, and 3.4 ± 0.4 m/sec, 3.3 ± 0.5 mm, 9.7 ± 2.1 mm, 14.5 ± 1.4 mm, 9.7 ± 1.2 mm, 2.1 ± 0.3 cm2, 2.3 ± 0.4 cm2, 2.1 ± 0.4 cm2, respectively. Individuals with HV had lower AbH and FHB thickness, cross-sectional area and SWV, however FDB thickness and cross-sectional area were higher in individuals with HV compared to that of individuals without HV (p < 0.05). PF thickness (p = 0.273), SWV of PF (p = 0.979) and FDB (p = 0.295) were similar in both groups. Conclusion: Our results suggest that individuals with HV had lower AbH and FHB stiffness, however PF and FDB stiffness were similar in HV and control group. In addition, AbH and FHB thickness and cross-sectional area were lower in individuals with HV; however, FDB thickness and cross-sectional area were higher in individuals with HV compared to that of individuals without HV. Level of Evidence: Level III, Diagnostic Study. Keywords: Hallux valgus, Foot muscles, Stiffness, Muscle size, Ultrasonography, Sonoelestographyhttp://www.sciencedirect.com/science/article/pii/S1017995X18303584
spellingShingle Serkan Taş
Alp Çetin
Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus
Acta Orthopaedica et Traumatologica Turcica
title Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus
title_full Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus
title_fullStr Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus
title_full_unstemmed Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus
title_short Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus
title_sort mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus
url http://www.sciencedirect.com/science/article/pii/S1017995X18303584
work_keys_str_mv AT serkantas mechanicalpropertiesandmorphologicfeaturesofintrinsicfootmusclesandplantarfasciainindividualswithhalluxvalgus
AT alpcetin mechanicalpropertiesandmorphologicfeaturesofintrinsicfootmusclesandplantarfasciainindividualswithhalluxvalgus