Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats

<abstract language="eng">A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342g) and three females (BW=3459g) were submitted to fi...

Full description

Bibliographic Details
Main Authors: N.C. Borges, R.S. Vasconcellos, J.C. Canola, F.J.A. Paula, A.C. Carciofi, G.T. Pereira
Format: Article
Language:English
Published: Universidade Federal de Minas Gerais 2008-02-01
Series:Arquivo Brasileiro de Medicina Veterinária e Zootecnia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000100037
_version_ 1818982016710868992
author N.C. Borges
R.S. Vasconcellos
J.C. Canola
F.J.A. Paula
A.C. Carciofi
G.T. Pereira
author_facet N.C. Borges
R.S. Vasconcellos
J.C. Canola
F.J.A. Paula
A.C. Carciofi
G.T. Pereira
author_sort N.C. Borges
collection DOAJ
description <abstract language="eng">A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342g) and three females (BW=3459g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy x-ray absorptiometry method provided precision for body composition measurements in adult cats.
first_indexed 2024-12-20T17:40:31Z
format Article
id doaj.art-40a024c33b624161a1f45f4ffbbed0de
institution Directory Open Access Journal
issn 0102-0935
1678-4162
language English
last_indexed 2024-12-20T17:40:31Z
publishDate 2008-02-01
publisher Universidade Federal de Minas Gerais
record_format Article
series Arquivo Brasileiro de Medicina Veterinária e Zootecnia
spelling doaj.art-40a024c33b624161a1f45f4ffbbed0de2022-12-21T19:31:07ZengUniversidade Federal de Minas GeraisArquivo Brasileiro de Medicina Veterinária e Zootecnia0102-09351678-41622008-02-0160126326610.1590/S0102-09352008000100037Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in catsN.C. BorgesR.S. VasconcellosJ.C. CanolaF.J.A. PaulaA.C. CarciofiG.T. Pereira<abstract language="eng">A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342g) and three females (BW=3459g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy x-ray absorptiometry method provided precision for body composition measurements in adult cats.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000100037catrepeatabilityDEXA
spellingShingle N.C. Borges
R.S. Vasconcellos
J.C. Canola
F.J.A. Paula
A.C. Carciofi
G.T. Pereira
Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats
Arquivo Brasileiro de Medicina Veterinária e Zootecnia
cat
repeatability
DEXA
title Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats
title_full Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats
title_fullStr Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats
title_full_unstemmed Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats
title_short Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats
title_sort precisao da tecnica de absorciometria de raios x de dupla energia na determinacao da composicao corporal em gatos precision of dual energy x ray absorptiometry for body composition measurements in cats
topic cat
repeatability
DEXA
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000100037
work_keys_str_mv AT ncborges precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats
AT rsvasconcellos precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats
AT jccanola precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats
AT fjapaula precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats
AT accarciofi precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats
AT gtpereira precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats