Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats
<abstract language="eng">A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342g) and three females (BW=3459g) were submitted to fi...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidade Federal de Minas Gerais
2008-02-01
|
Series: | Arquivo Brasileiro de Medicina Veterinária e Zootecnia |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000100037 |
_version_ | 1818982016710868992 |
---|---|
author | N.C. Borges R.S. Vasconcellos J.C. Canola F.J.A. Paula A.C. Carciofi G.T. Pereira |
author_facet | N.C. Borges R.S. Vasconcellos J.C. Canola F.J.A. Paula A.C. Carciofi G.T. Pereira |
author_sort | N.C. Borges |
collection | DOAJ |
description | <abstract language="eng">A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342g) and three females (BW=3459g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy x-ray absorptiometry method provided precision for body composition measurements in adult cats. |
first_indexed | 2024-12-20T17:40:31Z |
format | Article |
id | doaj.art-40a024c33b624161a1f45f4ffbbed0de |
institution | Directory Open Access Journal |
issn | 0102-0935 1678-4162 |
language | English |
last_indexed | 2024-12-20T17:40:31Z |
publishDate | 2008-02-01 |
publisher | Universidade Federal de Minas Gerais |
record_format | Article |
series | Arquivo Brasileiro de Medicina Veterinária e Zootecnia |
spelling | doaj.art-40a024c33b624161a1f45f4ffbbed0de2022-12-21T19:31:07ZengUniversidade Federal de Minas GeraisArquivo Brasileiro de Medicina Veterinária e Zootecnia0102-09351678-41622008-02-0160126326610.1590/S0102-09352008000100037Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in catsN.C. BorgesR.S. VasconcellosJ.C. CanolaF.J.A. PaulaA.C. CarciofiG.T. Pereira<abstract language="eng">A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342g) and three females (BW=3459g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy x-ray absorptiometry method provided precision for body composition measurements in adult cats.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000100037catrepeatabilityDEXA |
spellingShingle | N.C. Borges R.S. Vasconcellos J.C. Canola F.J.A. Paula A.C. Carciofi G.T. Pereira Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats Arquivo Brasileiro de Medicina Veterinária e Zootecnia cat repeatability DEXA |
title | Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats |
title_full | Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats |
title_fullStr | Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats |
title_full_unstemmed | Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats |
title_short | Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos Precision of dual energy x-ray absorptiometry for body composition measurements in cats |
title_sort | precisao da tecnica de absorciometria de raios x de dupla energia na determinacao da composicao corporal em gatos precision of dual energy x ray absorptiometry for body composition measurements in cats |
topic | cat repeatability DEXA |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352008000100037 |
work_keys_str_mv | AT ncborges precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats AT rsvasconcellos precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats AT jccanola precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats AT fjapaula precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats AT accarciofi precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats AT gtpereira precisaodatecnicadeabsorciometriaderaiosxdeduplaenergianadeterminacaodacomposicaocorporalemgatosprecisionofdualenergyxrayabsorptiometryforbodycompositionmeasurementsincats |