Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 Microspheres

Selective internal radiation therapy (SIRT) is a treatment modality for liver tumours during which radioactive microspheres are injected into the hepatic arterial tree. Holmium-166 (<sup>166</sup>Ho) microspheres used for SIRT can be visualized and quantified with MRI, potentially allowi...

Full description

Bibliographic Details
Main Authors: Joey Roosen, Mark J. Arntz, Marcel J. R. Janssen, Sytse F. de Jong, Jurgen J. Fütterer, Christiaan G. Overduin, J. Frank W. Nijsen
Format: Article
Language:English
Published: MDPI AG 2021-10-01
Series:Cancers
Subjects:
Online Access:https://www.mdpi.com/2072-6694/13/21/5462
_version_ 1797512700148842496
author Joey Roosen
Mark J. Arntz
Marcel J. R. Janssen
Sytse F. de Jong
Jurgen J. Fütterer
Christiaan G. Overduin
J. Frank W. Nijsen
author_facet Joey Roosen
Mark J. Arntz
Marcel J. R. Janssen
Sytse F. de Jong
Jurgen J. Fütterer
Christiaan G. Overduin
J. Frank W. Nijsen
author_sort Joey Roosen
collection DOAJ
description Selective internal radiation therapy (SIRT) is a treatment modality for liver tumours during which radioactive microspheres are injected into the hepatic arterial tree. Holmium-166 (<sup>166</sup>Ho) microspheres used for SIRT can be visualized and quantified with MRI, potentially allowing for MRI guidance during SIRT. The purpose of this study was to investigate the MRI compatibility of two angiography catheters and a microcatheter typically used for SIRT, and to explore the detectability of <sup>166</sup>Ho microspheres in a flow phantom using near real-time MRI. MR safety tests were performed at a 3 T MRI system according to American Society for Testing of Materials standard test methods. To assess the near real-time detectability of <sup>166</sup>Ho microspheres, a flow phantom was placed in the MRI bore and perfused using a peristaltic pump, simulating the flow in the hepatic artery. Dynamic MR imaging was performed using a 2D FLASH sequence during injection of different concentrations of <sup>166</sup>Ho microspheres. In the safety assessment, no significant heating (ΔT<sub>max</sub> 0.7 °C) was found in any catheter, and no magnetic interaction was found in two out of three of the used catheters. Near real-time MRI visualization of <sup>166</sup>Ho microsphere administration was feasible and depended on holmium concentration and vascular flow speed. Finally, we demonstrate preliminary imaging examples on the in vivo catheter visibility and near real-time imaging during <sup>166</sup>Ho microsphere administration in an initial patient case treated with SIRT in a clinical 3 T MRI. These results support additional research to establish the feasibility and safety of this procedure in vivo and enable the further development of a personalized MRI-guided approach to SIRT.
first_indexed 2024-03-10T06:05:24Z
format Article
id doaj.art-40ccb12fd39c43ba98bf1e35ec910439
institution Directory Open Access Journal
issn 2072-6694
language English
last_indexed 2024-03-10T06:05:24Z
publishDate 2021-10-01
publisher MDPI AG
record_format Article
series Cancers
spelling doaj.art-40ccb12fd39c43ba98bf1e35ec9104392023-11-22T20:35:38ZengMDPI AGCancers2072-66942021-10-011321546210.3390/cancers13215462Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 MicrospheresJoey Roosen0Mark J. Arntz1Marcel J. R. Janssen2Sytse F. de Jong3Jurgen J. Fütterer4Christiaan G. Overduin5J. Frank W. Nijsen6Department of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA Nijmegen, The NetherlandsDepartment of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA Nijmegen, The NetherlandsDepartment of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA Nijmegen, The NetherlandsDepartment of Cardiothoracic Surgery, Radboud University Medical Center, 6525 GA Nijmegen, The NetherlandsDepartment of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA Nijmegen, The NetherlandsDepartment of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA Nijmegen, The NetherlandsDepartment of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, 6525 GA Nijmegen, The NetherlandsSelective internal radiation therapy (SIRT) is a treatment modality for liver tumours during which radioactive microspheres are injected into the hepatic arterial tree. Holmium-166 (<sup>166</sup>Ho) microspheres used for SIRT can be visualized and quantified with MRI, potentially allowing for MRI guidance during SIRT. The purpose of this study was to investigate the MRI compatibility of two angiography catheters and a microcatheter typically used for SIRT, and to explore the detectability of <sup>166</sup>Ho microspheres in a flow phantom using near real-time MRI. MR safety tests were performed at a 3 T MRI system according to American Society for Testing of Materials standard test methods. To assess the near real-time detectability of <sup>166</sup>Ho microspheres, a flow phantom was placed in the MRI bore and perfused using a peristaltic pump, simulating the flow in the hepatic artery. Dynamic MR imaging was performed using a 2D FLASH sequence during injection of different concentrations of <sup>166</sup>Ho microspheres. In the safety assessment, no significant heating (ΔT<sub>max</sub> 0.7 °C) was found in any catheter, and no magnetic interaction was found in two out of three of the used catheters. Near real-time MRI visualization of <sup>166</sup>Ho microsphere administration was feasible and depended on holmium concentration and vascular flow speed. Finally, we demonstrate preliminary imaging examples on the in vivo catheter visibility and near real-time imaging during <sup>166</sup>Ho microsphere administration in an initial patient case treated with SIRT in a clinical 3 T MRI. These results support additional research to establish the feasibility and safety of this procedure in vivo and enable the further development of a personalized MRI-guided approach to SIRT.https://www.mdpi.com/2072-6694/13/21/5462SIRTradioembolizationholmiumMRIsafetycompatible
spellingShingle Joey Roosen
Mark J. Arntz
Marcel J. R. Janssen
Sytse F. de Jong
Jurgen J. Fütterer
Christiaan G. Overduin
J. Frank W. Nijsen
Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 Microspheres
Cancers
SIRT
radioembolization
holmium
MRI
safety
compatible
title Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 Microspheres
title_full Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 Microspheres
title_fullStr Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 Microspheres
title_full_unstemmed Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 Microspheres
title_short Development of an MRI-Guided Approach to Selective Internal Radiation Therapy Using Holmium-166 Microspheres
title_sort development of an mri guided approach to selective internal radiation therapy using holmium 166 microspheres
topic SIRT
radioembolization
holmium
MRI
safety
compatible
url https://www.mdpi.com/2072-6694/13/21/5462
work_keys_str_mv AT joeyroosen developmentofanmriguidedapproachtoselectiveinternalradiationtherapyusingholmium166microspheres
AT markjarntz developmentofanmriguidedapproachtoselectiveinternalradiationtherapyusingholmium166microspheres
AT marceljrjanssen developmentofanmriguidedapproachtoselectiveinternalradiationtherapyusingholmium166microspheres
AT sytsefdejong developmentofanmriguidedapproachtoselectiveinternalradiationtherapyusingholmium166microspheres
AT jurgenjfutterer developmentofanmriguidedapproachtoselectiveinternalradiationtherapyusingholmium166microspheres
AT christiaangoverduin developmentofanmriguidedapproachtoselectiveinternalradiationtherapyusingholmium166microspheres
AT jfrankwnijsen developmentofanmriguidedapproachtoselectiveinternalradiationtherapyusingholmium166microspheres