Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.
In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has bee...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2014-01-01
|
Series: | PLoS ONE |
Online Access: | https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24905826/?tool=EBI |
_version_ | 1819180957317464064 |
---|---|
author | Burcu Gumuscu Zeynep Erdogan Mustafa O Guler Turgay Tekinay |
author_facet | Burcu Gumuscu Zeynep Erdogan Mustafa O Guler Turgay Tekinay |
author_sort | Burcu Gumuscu |
collection | DOAJ |
description | In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has been developed using diol column. This approach improves on cost, time, and sensitivity over the existing methods, providing a simple and effective alternative. Total analysis time was less than 13 minutes including column re-equilibration between runs, in which water and acetonitrile were used as gradient elution solvents. Under optimized conditions, the minimum resolution between 2,4-DNT and 2,6-DNT peaks was 2.06. The recovery rates for spiked environmental samples were between 95-98%. The detection limits for diol column ranged from 0.78 to 1.17 µg/L for TNT and its byproducts. While the solvent consumption was 26.4 mL/min for two-phase EPA and 30 mL/min for EPA 8330 methods, it was only 8.8 mL/min for diol column. The resolution was improved up to 49% respect to two-phase EPA and EPA 8330 methods. When compared to C-18 and phenyl-3 columns, solvent usage was reduced up to 64% using diol column and resolution was enhanced approximately two-fold. The sensitivity of diol column was afforded by the hydroxyl groups on polyol layer, joining the formation of charge-transfer complexes with nitroaromatic compounds according to acceptor-donor interactions. Having compliance with current requirements, the proposed method demonstrates sensitive and robust separation. |
first_indexed | 2024-12-22T22:22:35Z |
format | Article |
id | doaj.art-410d4d36f77e430fbfa2261c7e93f21f |
institution | Directory Open Access Journal |
issn | 1932-6203 |
language | English |
last_indexed | 2024-12-22T22:22:35Z |
publishDate | 2014-01-01 |
publisher | Public Library of Science (PLoS) |
record_format | Article |
series | PLoS ONE |
spelling | doaj.art-410d4d36f77e430fbfa2261c7e93f21f2022-12-21T18:10:38ZengPublic Library of Science (PLoS)PLoS ONE1932-62032014-01-0196e9923010.1371/journal.pone.0099230Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.Burcu GumuscuZeynep ErdoganMustafa O GulerTurgay TekinayIn this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has been developed using diol column. This approach improves on cost, time, and sensitivity over the existing methods, providing a simple and effective alternative. Total analysis time was less than 13 minutes including column re-equilibration between runs, in which water and acetonitrile were used as gradient elution solvents. Under optimized conditions, the minimum resolution between 2,4-DNT and 2,6-DNT peaks was 2.06. The recovery rates for spiked environmental samples were between 95-98%. The detection limits for diol column ranged from 0.78 to 1.17 µg/L for TNT and its byproducts. While the solvent consumption was 26.4 mL/min for two-phase EPA and 30 mL/min for EPA 8330 methods, it was only 8.8 mL/min for diol column. The resolution was improved up to 49% respect to two-phase EPA and EPA 8330 methods. When compared to C-18 and phenyl-3 columns, solvent usage was reduced up to 64% using diol column and resolution was enhanced approximately two-fold. The sensitivity of diol column was afforded by the hydroxyl groups on polyol layer, joining the formation of charge-transfer complexes with nitroaromatic compounds according to acceptor-donor interactions. Having compliance with current requirements, the proposed method demonstrates sensitive and robust separation.https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24905826/?tool=EBI |
spellingShingle | Burcu Gumuscu Zeynep Erdogan Mustafa O Guler Turgay Tekinay Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography. PLoS ONE |
title | Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography. |
title_full | Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography. |
title_fullStr | Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography. |
title_full_unstemmed | Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography. |
title_short | Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography. |
title_sort | highly sensitive determination of 2 4 6 trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24905826/?tool=EBI |
work_keys_str_mv | AT burcugumuscu highlysensitivedeterminationof246trinitrotolueneandrelatedbyproductsusingadiolfunctionalizedcolumnforhighperformanceliquidchromatography AT zeyneperdogan highlysensitivedeterminationof246trinitrotolueneandrelatedbyproductsusingadiolfunctionalizedcolumnforhighperformanceliquidchromatography AT mustafaoguler highlysensitivedeterminationof246trinitrotolueneandrelatedbyproductsusingadiolfunctionalizedcolumnforhighperformanceliquidchromatography AT turgaytekinay highlysensitivedeterminationof246trinitrotolueneandrelatedbyproductsusingadiolfunctionalizedcolumnforhighperformanceliquidchromatography |