Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.

In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has bee...

Full description

Bibliographic Details
Main Authors: Burcu Gumuscu, Zeynep Erdogan, Mustafa O Guler, Turgay Tekinay
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2014-01-01
Series:PLoS ONE
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24905826/?tool=EBI
_version_ 1819180957317464064
author Burcu Gumuscu
Zeynep Erdogan
Mustafa O Guler
Turgay Tekinay
author_facet Burcu Gumuscu
Zeynep Erdogan
Mustafa O Guler
Turgay Tekinay
author_sort Burcu Gumuscu
collection DOAJ
description In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has been developed using diol column. This approach improves on cost, time, and sensitivity over the existing methods, providing a simple and effective alternative. Total analysis time was less than 13 minutes including column re-equilibration between runs, in which water and acetonitrile were used as gradient elution solvents. Under optimized conditions, the minimum resolution between 2,4-DNT and 2,6-DNT peaks was 2.06. The recovery rates for spiked environmental samples were between 95-98%. The detection limits for diol column ranged from 0.78 to 1.17 µg/L for TNT and its byproducts. While the solvent consumption was 26.4 mL/min for two-phase EPA and 30 mL/min for EPA 8330 methods, it was only 8.8 mL/min for diol column. The resolution was improved up to 49% respect to two-phase EPA and EPA 8330 methods. When compared to C-18 and phenyl-3 columns, solvent usage was reduced up to 64% using diol column and resolution was enhanced approximately two-fold. The sensitivity of diol column was afforded by the hydroxyl groups on polyol layer, joining the formation of charge-transfer complexes with nitroaromatic compounds according to acceptor-donor interactions. Having compliance with current requirements, the proposed method demonstrates sensitive and robust separation.
first_indexed 2024-12-22T22:22:35Z
format Article
id doaj.art-410d4d36f77e430fbfa2261c7e93f21f
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-22T22:22:35Z
publishDate 2014-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-410d4d36f77e430fbfa2261c7e93f21f2022-12-21T18:10:38ZengPublic Library of Science (PLoS)PLoS ONE1932-62032014-01-0196e9923010.1371/journal.pone.0099230Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.Burcu GumuscuZeynep ErdoganMustafa O GulerTurgay TekinayIn this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has been developed using diol column. This approach improves on cost, time, and sensitivity over the existing methods, providing a simple and effective alternative. Total analysis time was less than 13 minutes including column re-equilibration between runs, in which water and acetonitrile were used as gradient elution solvents. Under optimized conditions, the minimum resolution between 2,4-DNT and 2,6-DNT peaks was 2.06. The recovery rates for spiked environmental samples were between 95-98%. The detection limits for diol column ranged from 0.78 to 1.17 µg/L for TNT and its byproducts. While the solvent consumption was 26.4 mL/min for two-phase EPA and 30 mL/min for EPA 8330 methods, it was only 8.8 mL/min for diol column. The resolution was improved up to 49% respect to two-phase EPA and EPA 8330 methods. When compared to C-18 and phenyl-3 columns, solvent usage was reduced up to 64% using diol column and resolution was enhanced approximately two-fold. The sensitivity of diol column was afforded by the hydroxyl groups on polyol layer, joining the formation of charge-transfer complexes with nitroaromatic compounds according to acceptor-donor interactions. Having compliance with current requirements, the proposed method demonstrates sensitive and robust separation.https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24905826/?tool=EBI
spellingShingle Burcu Gumuscu
Zeynep Erdogan
Mustafa O Guler
Turgay Tekinay
Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.
PLoS ONE
title Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.
title_full Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.
title_fullStr Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.
title_full_unstemmed Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.
title_short Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.
title_sort highly sensitive determination of 2 4 6 trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography
url https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24905826/?tool=EBI
work_keys_str_mv AT burcugumuscu highlysensitivedeterminationof246trinitrotolueneandrelatedbyproductsusingadiolfunctionalizedcolumnforhighperformanceliquidchromatography
AT zeyneperdogan highlysensitivedeterminationof246trinitrotolueneandrelatedbyproductsusingadiolfunctionalizedcolumnforhighperformanceliquidchromatography
AT mustafaoguler highlysensitivedeterminationof246trinitrotolueneandrelatedbyproductsusingadiolfunctionalizedcolumnforhighperformanceliquidchromatography
AT turgaytekinay highlysensitivedeterminationof246trinitrotolueneandrelatedbyproductsusingadiolfunctionalizedcolumnforhighperformanceliquidchromatography