Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant

Purpose: To investigate the interobserver variations in delineation of lumpectomy cavity (LC) and clinical target volume (CTV), and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy. Material and methods : Delineation of L...

Full description

Bibliographic Details
Main Authors: Ritu Raj Upreti, Ashwini Budrukkar, Tabassum Wadasadawala, Shagun Misra, Lavanya Gurram, Rima Pathak, Deepak D. Deshpande
Format: Article
Language:English
Published: Termedia Publishing House 2017-02-01
Series:Journal of Contemporary Brachytherapy
Subjects:
Online Access:https://www.termedia.pl/Interobserver-variations-of-target-volume-delineation-and-its-impact-on-irradiated-volume-in-accelerated-partial-breast-irradiation-with-intraoperative-interstitial-breast-implant,54,29504,1,1.html
_version_ 1819146905313083392
author Ritu Raj Upreti
Ashwini Budrukkar
Tabassum Wadasadawala
Shagun Misra
Lavanya Gurram
Rima Pathak
Deepak D. Deshpande
author_facet Ritu Raj Upreti
Ashwini Budrukkar
Tabassum Wadasadawala
Shagun Misra
Lavanya Gurram
Rima Pathak
Deepak D. Deshpande
author_sort Ritu Raj Upreti
collection DOAJ
description Purpose: To investigate the interobserver variations in delineation of lumpectomy cavity (LC) and clinical target volume (CTV), and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy. Material and methods : Delineation of LC and CTV was done by five radiation oncologists on planning computed tomography (CT) scans of 20 patients with intraoperative interstitial breast implant. Cavity visualization index (CVI), four-point index ranging from (0 = poor) to (3 = excellent) was created and assigned by observers for each patient. In total, 200 contours for all observers and 100 treatment plans were evaluated. Spatial concordance (conformity index, CI common , and CIgen), average shift in the center of mass (COM), and ratio of maximum and minimum volumes (V max /V min ) of LC and CTV were quantified among all observers and statistically analyzed. Variation in active dwell positions (0.5 cm step) for each catheter, total reference air kerma (TRAK), volume enclosed by prescription isodose (V100%) among observers and its spatial concordance were analyzed. Results : The mean ± SD CI common of LC and CTV was 0.54 ± 0.09, and 0.58 ± 0.08, respectively. Conformity index tends to increase, shift in COM and V max /V min decrease significantly (p < 0.05), as CVI increased. Out of total 309 catheters, 29.8% catheters had no change, 29.8% and 17.5% catheters had variations of 1 and 2 dwell positions (0.5 cm and 1 cm), respectively. 9.3% catheters shown variations ≥ 10 dwell positions (5 cm). The mean ± SD CI common of V100% was 0.75 ± 0.11. The mean observed V max /V min of prescription isodose and TRAK was 1.18 (range, 1.03 to 1.56) and 1.11 (range, 1.03 to 1.35), respectively. Conclusions : Interobserver variability in delineation of target volume was found to be significantly related to CVI. Smaller variability was observed with excellent visualization of LC. Interobserver variations showed dosimetric impact on irradiation of breast tissue volume with prescription dose.
first_indexed 2024-12-22T13:21:21Z
format Article
id doaj.art-41743bd770b2460682ac2db0e0015f33
institution Directory Open Access Journal
issn 1689-832X
2081-2841
language English
last_indexed 2024-12-22T13:21:21Z
publishDate 2017-02-01
publisher Termedia Publishing House
record_format Article
series Journal of Contemporary Brachytherapy
spelling doaj.art-41743bd770b2460682ac2db0e0015f332022-12-21T18:24:28ZengTermedia Publishing HouseJournal of Contemporary Brachytherapy1689-832X2081-28412017-02-019213914510.5114/jcb.2017.6602729504Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implantRitu Raj UpretiAshwini BudrukkarTabassum WadasadawalaShagun MisraLavanya GurramRima PathakDeepak D. DeshpandePurpose: To investigate the interobserver variations in delineation of lumpectomy cavity (LC) and clinical target volume (CTV), and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy. Material and methods : Delineation of LC and CTV was done by five radiation oncologists on planning computed tomography (CT) scans of 20 patients with intraoperative interstitial breast implant. Cavity visualization index (CVI), four-point index ranging from (0 = poor) to (3 = excellent) was created and assigned by observers for each patient. In total, 200 contours for all observers and 100 treatment plans were evaluated. Spatial concordance (conformity index, CI common , and CIgen), average shift in the center of mass (COM), and ratio of maximum and minimum volumes (V max /V min ) of LC and CTV were quantified among all observers and statistically analyzed. Variation in active dwell positions (0.5 cm step) for each catheter, total reference air kerma (TRAK), volume enclosed by prescription isodose (V100%) among observers and its spatial concordance were analyzed. Results : The mean ± SD CI common of LC and CTV was 0.54 ± 0.09, and 0.58 ± 0.08, respectively. Conformity index tends to increase, shift in COM and V max /V min decrease significantly (p < 0.05), as CVI increased. Out of total 309 catheters, 29.8% catheters had no change, 29.8% and 17.5% catheters had variations of 1 and 2 dwell positions (0.5 cm and 1 cm), respectively. 9.3% catheters shown variations ≥ 10 dwell positions (5 cm). The mean ± SD CI common of V100% was 0.75 ± 0.11. The mean observed V max /V min of prescription isodose and TRAK was 1.18 (range, 1.03 to 1.56) and 1.11 (range, 1.03 to 1.35), respectively. Conclusions : Interobserver variability in delineation of target volume was found to be significantly related to CVI. Smaller variability was observed with excellent visualization of LC. Interobserver variations showed dosimetric impact on irradiation of breast tissue volume with prescription dose.https://www.termedia.pl/Interobserver-variations-of-target-volume-delineation-and-its-impact-on-irradiated-volume-in-accelerated-partial-breast-irradiation-with-intraoperative-interstitial-breast-implant,54,29504,1,1.htmlAPBI breast cancer cavity visualization interobserver variation
spellingShingle Ritu Raj Upreti
Ashwini Budrukkar
Tabassum Wadasadawala
Shagun Misra
Lavanya Gurram
Rima Pathak
Deepak D. Deshpande
Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant
Journal of Contemporary Brachytherapy
APBI
breast cancer
cavity visualization
interobserver variation
title Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant
title_full Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant
title_fullStr Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant
title_full_unstemmed Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant
title_short Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant
title_sort interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant
topic APBI
breast cancer
cavity visualization
interobserver variation
url https://www.termedia.pl/Interobserver-variations-of-target-volume-delineation-and-its-impact-on-irradiated-volume-in-accelerated-partial-breast-irradiation-with-intraoperative-interstitial-breast-implant,54,29504,1,1.html
work_keys_str_mv AT riturajupreti interobservervariationsoftargetvolumedelineationanditsimpactonirradiatedvolumeinacceleratedpartialbreastirradiationwithintraoperativeinterstitialbreastimplant
AT ashwinibudrukkar interobservervariationsoftargetvolumedelineationanditsimpactonirradiatedvolumeinacceleratedpartialbreastirradiationwithintraoperativeinterstitialbreastimplant
AT tabassumwadasadawala interobservervariationsoftargetvolumedelineationanditsimpactonirradiatedvolumeinacceleratedpartialbreastirradiationwithintraoperativeinterstitialbreastimplant
AT shagunmisra interobservervariationsoftargetvolumedelineationanditsimpactonirradiatedvolumeinacceleratedpartialbreastirradiationwithintraoperativeinterstitialbreastimplant
AT lavanyagurram interobservervariationsoftargetvolumedelineationanditsimpactonirradiatedvolumeinacceleratedpartialbreastirradiationwithintraoperativeinterstitialbreastimplant
AT rimapathak interobservervariationsoftargetvolumedelineationanditsimpactonirradiatedvolumeinacceleratedpartialbreastirradiationwithintraoperativeinterstitialbreastimplant
AT deepakddeshpande interobservervariationsoftargetvolumedelineationanditsimpactonirradiatedvolumeinacceleratedpartialbreastirradiationwithintraoperativeinterstitialbreastimplant