Surface-Enhanced Raman Analysis of Uric Acid and Hypoxanthine Analysis in Fractionated Bodily Fluids

In recent years, the disease burden of hyperuricemia has been increasing, especially in high-income countries and the economically developing world with a Western lifestyle. Abnormal levels of uric acid and hypoxanthine are associated with many diseases, and therefore, to demonstrate improved method...

Full description

Bibliographic Details
Main Authors: Furong Tian, Luis Felipe das Chagas e Silva de Carvalho, Alan Casey, Marcelo Saito Nogueira, Hugh J. Byrne
Format: Article
Language:English
Published: MDPI AG 2023-03-01
Series:Nanomaterials
Subjects:
Online Access:https://www.mdpi.com/2079-4991/13/7/1216
_version_ 1797607328514572288
author Furong Tian
Luis Felipe das Chagas e Silva de Carvalho
Alan Casey
Marcelo Saito Nogueira
Hugh J. Byrne
author_facet Furong Tian
Luis Felipe das Chagas e Silva de Carvalho
Alan Casey
Marcelo Saito Nogueira
Hugh J. Byrne
author_sort Furong Tian
collection DOAJ
description In recent years, the disease burden of hyperuricemia has been increasing, especially in high-income countries and the economically developing world with a Western lifestyle. Abnormal levels of uric acid and hypoxanthine are associated with many diseases, and therefore, to demonstrate improved methods of uric acid and hypoxanthine detection, three different bodily fluids were analysed using surface-enhanced Raman spectroscopy (SERS) and high-performance liquid chromatography (HPLC). Gold nanostar suspensions were mixed with series dilutions of uric acid and hypoxanthine, 3 kDa centrifugally filtered human blood serum, urine and saliva. The results show that gold nanostars enable the quantitative detection of the concentration of uric acid and hypoxanthine in the range 5–50 μg/mL and 50–250 ng/mL, respectively. The peak areas of HPLC and maximum peak intensity of SERS have strongly correlated, notably with the peaks of uric acid and hypoxanthine at 1000 and 640 cm<sup>−1</sup>, respectively. The r<sup>2</sup> is 0.975 and 0.959 for uric acid and hypoxanthine, respectively. Each of the three body fluids has a number of spectral features in common with uric acid and hypoxanthine. The large overlap of the spectral bands of the SERS of uric acid against three body fluids at spectra peaks were at 442, 712, 802, 1000, 1086, 1206, 1343, 1436 and 1560 cm<sup>−1</sup>. The features at 560, 640, 803, 1206, 1290 and 1620 cm<sup>−1</sup> from hypoxanthine were common to serum, saliva and urine. There is no statistical difference between HPLC and SERS for determination of the concentration of uric acid and hypoxanthine (<i>p</i> > 0.05). For clinical applications, 3 kDa centrifugal filtration followed by SERS can be used for uric acid and hypoxanthine screening is, which can be used to reveal the subtle abnormalities enhancing the great potential of vibrational spectroscopy as an analytical tool. Our work supports the hypnosis that it is possible to obtain the specific concentration of uric acid and hypoxanthine by comparing the SER signals of serum, saliva and urine. In the future, the analysis of other biofluids can be employed to detect biomarkers for the diagnosis of systemic pathologies.
first_indexed 2024-03-11T05:28:36Z
format Article
id doaj.art-4245bb5a26aa4c6db2e5d597232cd612
institution Directory Open Access Journal
issn 2079-4991
language English
last_indexed 2024-03-11T05:28:36Z
publishDate 2023-03-01
publisher MDPI AG
record_format Article
series Nanomaterials
spelling doaj.art-4245bb5a26aa4c6db2e5d597232cd6122023-11-17T17:17:22ZengMDPI AGNanomaterials2079-49912023-03-01137121610.3390/nano13071216Surface-Enhanced Raman Analysis of Uric Acid and Hypoxanthine Analysis in Fractionated Bodily FluidsFurong Tian0Luis Felipe das Chagas e Silva de Carvalho1Alan Casey2Marcelo Saito Nogueira3Hugh J. Byrne4FOCAS Research Institute, Technological University Dublin Camden Row, D08CKP1 Dublin, IrelandFOCAS Research Institute, Technological University Dublin Camden Row, D08CKP1 Dublin, IrelandFOCAS Research Institute, Technological University Dublin Camden Row, D08CKP1 Dublin, IrelandTyndall National Institute, Lee Maltings Complex, Dyke Parade, T12R5CP Cork, IrelandFOCAS Research Institute, Technological University Dublin Camden Row, D08CKP1 Dublin, IrelandIn recent years, the disease burden of hyperuricemia has been increasing, especially in high-income countries and the economically developing world with a Western lifestyle. Abnormal levels of uric acid and hypoxanthine are associated with many diseases, and therefore, to demonstrate improved methods of uric acid and hypoxanthine detection, three different bodily fluids were analysed using surface-enhanced Raman spectroscopy (SERS) and high-performance liquid chromatography (HPLC). Gold nanostar suspensions were mixed with series dilutions of uric acid and hypoxanthine, 3 kDa centrifugally filtered human blood serum, urine and saliva. The results show that gold nanostars enable the quantitative detection of the concentration of uric acid and hypoxanthine in the range 5–50 μg/mL and 50–250 ng/mL, respectively. The peak areas of HPLC and maximum peak intensity of SERS have strongly correlated, notably with the peaks of uric acid and hypoxanthine at 1000 and 640 cm<sup>−1</sup>, respectively. The r<sup>2</sup> is 0.975 and 0.959 for uric acid and hypoxanthine, respectively. Each of the three body fluids has a number of spectral features in common with uric acid and hypoxanthine. The large overlap of the spectral bands of the SERS of uric acid against three body fluids at spectra peaks were at 442, 712, 802, 1000, 1086, 1206, 1343, 1436 and 1560 cm<sup>−1</sup>. The features at 560, 640, 803, 1206, 1290 and 1620 cm<sup>−1</sup> from hypoxanthine were common to serum, saliva and urine. There is no statistical difference between HPLC and SERS for determination of the concentration of uric acid and hypoxanthine (<i>p</i> > 0.05). For clinical applications, 3 kDa centrifugal filtration followed by SERS can be used for uric acid and hypoxanthine screening is, which can be used to reveal the subtle abnormalities enhancing the great potential of vibrational spectroscopy as an analytical tool. Our work supports the hypnosis that it is possible to obtain the specific concentration of uric acid and hypoxanthine by comparing the SER signals of serum, saliva and urine. In the future, the analysis of other biofluids can be employed to detect biomarkers for the diagnosis of systemic pathologies.https://www.mdpi.com/2079-4991/13/7/1216vibrational spectroscopybodily fluidsblood serumsalivaurinesurface-enhanced Raman spectroscopy
spellingShingle Furong Tian
Luis Felipe das Chagas e Silva de Carvalho
Alan Casey
Marcelo Saito Nogueira
Hugh J. Byrne
Surface-Enhanced Raman Analysis of Uric Acid and Hypoxanthine Analysis in Fractionated Bodily Fluids
Nanomaterials
vibrational spectroscopy
bodily fluids
blood serum
saliva
urine
surface-enhanced Raman spectroscopy
title Surface-Enhanced Raman Analysis of Uric Acid and Hypoxanthine Analysis in Fractionated Bodily Fluids
title_full Surface-Enhanced Raman Analysis of Uric Acid and Hypoxanthine Analysis in Fractionated Bodily Fluids
title_fullStr Surface-Enhanced Raman Analysis of Uric Acid and Hypoxanthine Analysis in Fractionated Bodily Fluids
title_full_unstemmed Surface-Enhanced Raman Analysis of Uric Acid and Hypoxanthine Analysis in Fractionated Bodily Fluids
title_short Surface-Enhanced Raman Analysis of Uric Acid and Hypoxanthine Analysis in Fractionated Bodily Fluids
title_sort surface enhanced raman analysis of uric acid and hypoxanthine analysis in fractionated bodily fluids
topic vibrational spectroscopy
bodily fluids
blood serum
saliva
urine
surface-enhanced Raman spectroscopy
url https://www.mdpi.com/2079-4991/13/7/1216
work_keys_str_mv AT furongtian surfaceenhancedramananalysisofuricacidandhypoxanthineanalysisinfractionatedbodilyfluids
AT luisfelipedaschagasesilvadecarvalho surfaceenhancedramananalysisofuricacidandhypoxanthineanalysisinfractionatedbodilyfluids
AT alancasey surfaceenhancedramananalysisofuricacidandhypoxanthineanalysisinfractionatedbodilyfluids
AT marcelosaitonogueira surfaceenhancedramananalysisofuricacidandhypoxanthineanalysisinfractionatedbodilyfluids
AT hughjbyrne surfaceenhancedramananalysisofuricacidandhypoxanthineanalysisinfractionatedbodilyfluids