Gas-Phase Biosensors (Bio-Sniffers) for Measurement of 2-Nonenal, the Causative Volatile Molecule of Human Aging-Related Body Odor

The molecule 2-nonenal is renowned as the origin of unpleasant human aging-related body odor that can potentially indicate age-related metabolic changes. Most 2-nonenal measurements rely on chromatographic analytical systems, which pose challenges in terms of daily usage and the ability to track cha...

Full description

Bibliographic Details
Main Authors: Kenta Iitani, Hidehisa Mori, Kenta Ichikawa, Koji Toma, Takahiro Arakawa, Yasuhiko Iwasaki, Kohji Mitsubayashi
Format: Article
Language:English
Published: MDPI AG 2023-06-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/23/13/5857
_version_ 1797590843047018496
author Kenta Iitani
Hidehisa Mori
Kenta Ichikawa
Koji Toma
Takahiro Arakawa
Yasuhiko Iwasaki
Kohji Mitsubayashi
author_facet Kenta Iitani
Hidehisa Mori
Kenta Ichikawa
Koji Toma
Takahiro Arakawa
Yasuhiko Iwasaki
Kohji Mitsubayashi
author_sort Kenta Iitani
collection DOAJ
description The molecule 2-nonenal is renowned as the origin of unpleasant human aging-related body odor that can potentially indicate age-related metabolic changes. Most 2-nonenal measurements rely on chromatographic analytical systems, which pose challenges in terms of daily usage and the ability to track changes in concentration over time. In this study, we have developed liquid- and gas-phase biosensors (bio-sniffers) with the aim of enabling facile and continuous measurement of <i>trans</i>-2-nonenal vapor. Initially, we compared two types of nicotinamide adenine dinucleotide (phosphate) [NAD(P)]-dependent enzymes that have the catalytic ability of <i>trans</i>-2-nonenal: aldehyde dehydrogenase (ALDH) and enone reductase 1 (ER1). The developed sensor quantified the <i>trans</i>-2-nonanal concentration by measuring fluorescence (excitation: 340 nm, emission: 490 nm) emitted from NAD(P)H that was generated or consumed by ALDH or ER1. The ALDH biosensor reacted to a variety of aldehydes including <i>trans</i>-2-nonenal, whereas the ER1 biosensor showed high selectivity. In contrast, the ALDH bio-sniffer showed quantitative characteristics for <i>trans</i>-2-nonenal vapor at a concentration range of 0.4–7.5 ppm (with a theoretical limit of detection (LOD) and limit of quantification (LOQ) of 0.23 and 0.26 ppm, respectively), including a reported concentration (0.85–4.35 ppm), whereas the ER1 bio-sniffer detected only 0.4 and 0.8 ppm. Based on these findings, headspace gas of skin-wiped alcohol-absorbed cotton collected from study participants in their 20s and 50s was measured by the ALDH bio-sniffer. Consequently, age-related differences in signals were observed, suggesting the potential for measuring <i>trans</i>-2-nonenal vapor.
first_indexed 2024-03-11T01:29:14Z
format Article
id doaj.art-4276580e747e4f7f98bc14e642fc460f
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-11T01:29:14Z
publishDate 2023-06-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-4276580e747e4f7f98bc14e642fc460f2023-11-18T17:27:47ZengMDPI AGSensors1424-82202023-06-012313585710.3390/s23135857Gas-Phase Biosensors (Bio-Sniffers) for Measurement of 2-Nonenal, the Causative Volatile Molecule of Human Aging-Related Body OdorKenta Iitani0Hidehisa Mori1Kenta Ichikawa2Koji Toma3Takahiro Arakawa4Yasuhiko Iwasaki5Kohji Mitsubayashi6Department of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo 101-0062, JapanGraduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo 113-8510, JapanDepartment of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo 101-0062, JapanDepartment of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo 101-0062, JapanDepartment of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo 101-0062, JapanFaculty of Chemistry, Materials and Bioengineering, Kansai University, Osaka 564-8680, JapanDepartment of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), Tokyo 101-0062, JapanThe molecule 2-nonenal is renowned as the origin of unpleasant human aging-related body odor that can potentially indicate age-related metabolic changes. Most 2-nonenal measurements rely on chromatographic analytical systems, which pose challenges in terms of daily usage and the ability to track changes in concentration over time. In this study, we have developed liquid- and gas-phase biosensors (bio-sniffers) with the aim of enabling facile and continuous measurement of <i>trans</i>-2-nonenal vapor. Initially, we compared two types of nicotinamide adenine dinucleotide (phosphate) [NAD(P)]-dependent enzymes that have the catalytic ability of <i>trans</i>-2-nonenal: aldehyde dehydrogenase (ALDH) and enone reductase 1 (ER1). The developed sensor quantified the <i>trans</i>-2-nonanal concentration by measuring fluorescence (excitation: 340 nm, emission: 490 nm) emitted from NAD(P)H that was generated or consumed by ALDH or ER1. The ALDH biosensor reacted to a variety of aldehydes including <i>trans</i>-2-nonenal, whereas the ER1 biosensor showed high selectivity. In contrast, the ALDH bio-sniffer showed quantitative characteristics for <i>trans</i>-2-nonenal vapor at a concentration range of 0.4–7.5 ppm (with a theoretical limit of detection (LOD) and limit of quantification (LOQ) of 0.23 and 0.26 ppm, respectively), including a reported concentration (0.85–4.35 ppm), whereas the ER1 bio-sniffer detected only 0.4 and 0.8 ppm. Based on these findings, headspace gas of skin-wiped alcohol-absorbed cotton collected from study participants in their 20s and 50s was measured by the ALDH bio-sniffer. Consequently, age-related differences in signals were observed, suggesting the potential for measuring <i>trans</i>-2-nonenal vapor.https://www.mdpi.com/1424-8220/23/13/5857gas-phase biosensor<i>trans</i>-2-nonenalbody odoragingfluorescence
spellingShingle Kenta Iitani
Hidehisa Mori
Kenta Ichikawa
Koji Toma
Takahiro Arakawa
Yasuhiko Iwasaki
Kohji Mitsubayashi
Gas-Phase Biosensors (Bio-Sniffers) for Measurement of 2-Nonenal, the Causative Volatile Molecule of Human Aging-Related Body Odor
Sensors
gas-phase biosensor
<i>trans</i>-2-nonenal
body odor
aging
fluorescence
title Gas-Phase Biosensors (Bio-Sniffers) for Measurement of 2-Nonenal, the Causative Volatile Molecule of Human Aging-Related Body Odor
title_full Gas-Phase Biosensors (Bio-Sniffers) for Measurement of 2-Nonenal, the Causative Volatile Molecule of Human Aging-Related Body Odor
title_fullStr Gas-Phase Biosensors (Bio-Sniffers) for Measurement of 2-Nonenal, the Causative Volatile Molecule of Human Aging-Related Body Odor
title_full_unstemmed Gas-Phase Biosensors (Bio-Sniffers) for Measurement of 2-Nonenal, the Causative Volatile Molecule of Human Aging-Related Body Odor
title_short Gas-Phase Biosensors (Bio-Sniffers) for Measurement of 2-Nonenal, the Causative Volatile Molecule of Human Aging-Related Body Odor
title_sort gas phase biosensors bio sniffers for measurement of 2 nonenal the causative volatile molecule of human aging related body odor
topic gas-phase biosensor
<i>trans</i>-2-nonenal
body odor
aging
fluorescence
url https://www.mdpi.com/1424-8220/23/13/5857
work_keys_str_mv AT kentaiitani gasphasebiosensorsbiosniffersformeasurementof2nonenalthecausativevolatilemoleculeofhumanagingrelatedbodyodor
AT hidehisamori gasphasebiosensorsbiosniffersformeasurementof2nonenalthecausativevolatilemoleculeofhumanagingrelatedbodyodor
AT kentaichikawa gasphasebiosensorsbiosniffersformeasurementof2nonenalthecausativevolatilemoleculeofhumanagingrelatedbodyodor
AT kojitoma gasphasebiosensorsbiosniffersformeasurementof2nonenalthecausativevolatilemoleculeofhumanagingrelatedbodyodor
AT takahiroarakawa gasphasebiosensorsbiosniffersformeasurementof2nonenalthecausativevolatilemoleculeofhumanagingrelatedbodyodor
AT yasuhikoiwasaki gasphasebiosensorsbiosniffersformeasurementof2nonenalthecausativevolatilemoleculeofhumanagingrelatedbodyodor
AT kohjimitsubayashi gasphasebiosensorsbiosniffersformeasurementof2nonenalthecausativevolatilemoleculeofhumanagingrelatedbodyodor