Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings

<b><i>Background</i></b>: During mammography, a lead-acrylic protective screen is recommended to reduce radiation exposure to the unexposed breast. Objectives: This research study aimed to construct an Indium-(III)-oxide-rich tellurite-glass screen (TZI8) and compare its perf...

Full description

Bibliographic Details
Main Authors: Ghada ALMisned, Wiam Elshami, Gokhan Kilic, Erkan Ilik, Elaf Rabaa, Hesham M. H. Zakaly, Antoaneta Ene, Huseyin O. Tekin
Format: Article
Language:English
Published: MDPI AG 2023-02-01
Series:Medicina
Subjects:
Online Access:https://www.mdpi.com/1648-9144/59/2/327
_version_ 1797619439302082560
author Ghada ALMisned
Wiam Elshami
Gokhan Kilic
Erkan Ilik
Elaf Rabaa
Hesham M. H. Zakaly
Antoaneta Ene
Huseyin O. Tekin
author_facet Ghada ALMisned
Wiam Elshami
Gokhan Kilic
Erkan Ilik
Elaf Rabaa
Hesham M. H. Zakaly
Antoaneta Ene
Huseyin O. Tekin
author_sort Ghada ALMisned
collection DOAJ
description <b><i>Background</i></b>: During mammography, a lead-acrylic protective screen is recommended to reduce radiation exposure to the unexposed breast. Objectives: This research study aimed to construct an Indium-(III)-oxide-rich tellurite-glass screen (TZI8) and compare its performance to that of lead acrylic. <b><i>Materials and Methods</i></b>: A three-layer heterogeneous-breast phantom was developed, using the MCNPX (version 2.7.0) Monte Carlo code. An MCNPX-simulation geometry was designed and implemented, using the lead-acrylic and TZI8 shielding screens between the right and left breast. Next, the reliability of the phantom and the variations in absorption between the lead-acrylic and TZI8 glass were investigated. <b><i>Results:</i></b> The findings show that the TZI8-protective-glass screen offers significantly greater radioprotection than the lead-acrylic material. The quantity of total dose absorbed in the unexposed breast was much lower for TZI8 than for lead-based acrylic. The TZI8-glass screen gives about 60% more radioprotection than the lead-acrylic screen. <b><i>Conclusion:</i></b> Considering the toxic lead in the structure that may be hazardous to the human tissues, the TZI8-glass screen may be used in mammography examination to provide greater radioprotection than the lead-acrylic screen, in order to greatly reduce the dose to the unexposed breast.
first_indexed 2024-03-11T08:27:09Z
format Article
id doaj.art-4289a01aa17640b2a9b21d0484c1b21a
institution Directory Open Access Journal
issn 1010-660X
1648-9144
language English
last_indexed 2024-03-11T08:27:09Z
publishDate 2023-02-01
publisher MDPI AG
record_format Article
series Medicina
spelling doaj.art-4289a01aa17640b2a9b21d0484c1b21a2023-11-16T22:00:16ZengMDPI AGMedicina1010-660X1648-91442023-02-0159232710.3390/medicina59020327Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical FindingsGhada ALMisned0Wiam Elshami1Gokhan Kilic2Erkan Ilik3Elaf Rabaa4Hesham M. H. Zakaly5Antoaneta Ene6Huseyin O. Tekin7Department of Physics, College of Science, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi ArabiaMedical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab EmiratesDepartment of Physics, Faculty of Science, Eskisehir Osmangazi University, Eskisehir 26040, TürkiyeDepartment of Physics, Faculty of Science, Eskisehir Osmangazi University, Eskisehir 26040, TürkiyeMedical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab EmiratesInstitute of Physics and Technology, Ural Federal University, 620002 Ekaterinburg, RussiaINPOLDE Research Center, Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, Dunarea de Jos University of Galati, 47 Domneasca Street, 800008 Galati, RomaniaMedical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates<b><i>Background</i></b>: During mammography, a lead-acrylic protective screen is recommended to reduce radiation exposure to the unexposed breast. Objectives: This research study aimed to construct an Indium-(III)-oxide-rich tellurite-glass screen (TZI8) and compare its performance to that of lead acrylic. <b><i>Materials and Methods</i></b>: A three-layer heterogeneous-breast phantom was developed, using the MCNPX (version 2.7.0) Monte Carlo code. An MCNPX-simulation geometry was designed and implemented, using the lead-acrylic and TZI8 shielding screens between the right and left breast. Next, the reliability of the phantom and the variations in absorption between the lead-acrylic and TZI8 glass were investigated. <b><i>Results:</i></b> The findings show that the TZI8-protective-glass screen offers significantly greater radioprotection than the lead-acrylic material. The quantity of total dose absorbed in the unexposed breast was much lower for TZI8 than for lead-based acrylic. The TZI8-glass screen gives about 60% more radioprotection than the lead-acrylic screen. <b><i>Conclusion:</i></b> Considering the toxic lead in the structure that may be hazardous to the human tissues, the TZI8-glass screen may be used in mammography examination to provide greater radioprotection than the lead-acrylic screen, in order to greatly reduce the dose to the unexposed breast.https://www.mdpi.com/1648-9144/59/2/327breast dosimetrymammographyX-rayradiation protection
spellingShingle Ghada ALMisned
Wiam Elshami
Gokhan Kilic
Erkan Ilik
Elaf Rabaa
Hesham M. H. Zakaly
Antoaneta Ene
Huseyin O. Tekin
Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings
Medicina
breast dosimetry
mammography
X-ray
radiation protection
title Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings
title_full Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings
title_fullStr Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings
title_full_unstemmed Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings
title_short Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings
title_sort exploring the radioprotective indium iii oxide screens for mammography scans using a three layer heterogeneous breast phantom and mcnpx a comparative study using clinical findings
topic breast dosimetry
mammography
X-ray
radiation protection
url https://www.mdpi.com/1648-9144/59/2/327
work_keys_str_mv AT ghadaalmisned exploringtheradioprotectiveindiumiiioxidescreensformammographyscansusingathreelayerheterogeneousbreastphantomandmcnpxacomparativestudyusingclinicalfindings
AT wiamelshami exploringtheradioprotectiveindiumiiioxidescreensformammographyscansusingathreelayerheterogeneousbreastphantomandmcnpxacomparativestudyusingclinicalfindings
AT gokhankilic exploringtheradioprotectiveindiumiiioxidescreensformammographyscansusingathreelayerheterogeneousbreastphantomandmcnpxacomparativestudyusingclinicalfindings
AT erkanilik exploringtheradioprotectiveindiumiiioxidescreensformammographyscansusingathreelayerheterogeneousbreastphantomandmcnpxacomparativestudyusingclinicalfindings
AT elafrabaa exploringtheradioprotectiveindiumiiioxidescreensformammographyscansusingathreelayerheterogeneousbreastphantomandmcnpxacomparativestudyusingclinicalfindings
AT heshammhzakaly exploringtheradioprotectiveindiumiiioxidescreensformammographyscansusingathreelayerheterogeneousbreastphantomandmcnpxacomparativestudyusingclinicalfindings
AT antoanetaene exploringtheradioprotectiveindiumiiioxidescreensformammographyscansusingathreelayerheterogeneousbreastphantomandmcnpxacomparativestudyusingclinicalfindings
AT huseyinotekin exploringtheradioprotectiveindiumiiioxidescreensformammographyscansusingathreelayerheterogeneousbreastphantomandmcnpxacomparativestudyusingclinicalfindings