Reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles.
The reliability of MyotonPRO that can monitor the mechanical properties of tissues is still unclear. This study aimed to analyze the within-day inter-operator and between-day intra-operator reliability of MyotonPRO for assessing tone and stiffness of quadriceps femoris and patellar tendon at differe...
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2019-01-01
|
Series: | PLoS ONE |
Online Access: | https://doi.org/10.1371/journal.pone.0220521 |
_version_ | 1818588771688382464 |
---|---|
author | Guoqian Chen Jiatao Wu Guocai Chen Yanyan Lu Wei Ren Wu Xu Xuemeng Xu Zugui Wu Yingxin Guan Yi Zheng Bofan Qiu |
author_facet | Guoqian Chen Jiatao Wu Guocai Chen Yanyan Lu Wei Ren Wu Xu Xuemeng Xu Zugui Wu Yingxin Guan Yi Zheng Bofan Qiu |
author_sort | Guoqian Chen |
collection | DOAJ |
description | The reliability of MyotonPRO that can monitor the mechanical properties of tissues is still unclear. This study aimed to analyze the within-day inter-operator and between-day intra-operator reliability of MyotonPRO for assessing tone and stiffness of quadriceps femoris and patellar tendon at different knee angles. The tone and stiffness of healthy participants (15 males and 15 females, aged 24.7±1.6 years) in the supine and resting position were measured using the MyotonPRO device. The measurements were quantified at 0°, 30°, 60°, and 90° of knee flexion. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated and a Bland-Altman analysis was conducted to estimate reliability. The results indicated excellent inter-operator reliability (ICC > 0.78) and good to excellent intra-operator reliability (ICC > 0.41). The inter-operator SEM measurements ranged between 0.1-0.9 Hz and 3.8-37.9 N/m, and intra-operator SEM ranged between 0.5-1.3 Hz and 7.9-52.0 N/m. The inter-operator MDC ranged between 0.3-2.5 Hz and 10.5-105.1 N/m, and intra-operator SEM ranged between 1.1-3.3 Hz and 21.9-144.1 N/m. The agreement of inter-operator was better than that of intra-operator. The study concluded that MyotonPRO is a reliable device to detect the tone and stiffness of quadriceps femoris and patellar tendon. |
first_indexed | 2024-12-16T09:30:03Z |
format | Article |
id | doaj.art-42f56b70f269416cbd4bc67ef7c428ac |
institution | Directory Open Access Journal |
issn | 1932-6203 |
language | English |
last_indexed | 2024-12-16T09:30:03Z |
publishDate | 2019-01-01 |
publisher | Public Library of Science (PLoS) |
record_format | Article |
series | PLoS ONE |
spelling | doaj.art-42f56b70f269416cbd4bc67ef7c428ac2022-12-21T22:36:33ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-01147e022052110.1371/journal.pone.0220521Reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles.Guoqian ChenJiatao WuGuocai ChenYanyan LuWei RenWu XuXuemeng XuZugui WuYingxin GuanYi ZhengBofan QiuThe reliability of MyotonPRO that can monitor the mechanical properties of tissues is still unclear. This study aimed to analyze the within-day inter-operator and between-day intra-operator reliability of MyotonPRO for assessing tone and stiffness of quadriceps femoris and patellar tendon at different knee angles. The tone and stiffness of healthy participants (15 males and 15 females, aged 24.7±1.6 years) in the supine and resting position were measured using the MyotonPRO device. The measurements were quantified at 0°, 30°, 60°, and 90° of knee flexion. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated and a Bland-Altman analysis was conducted to estimate reliability. The results indicated excellent inter-operator reliability (ICC > 0.78) and good to excellent intra-operator reliability (ICC > 0.41). The inter-operator SEM measurements ranged between 0.1-0.9 Hz and 3.8-37.9 N/m, and intra-operator SEM ranged between 0.5-1.3 Hz and 7.9-52.0 N/m. The inter-operator MDC ranged between 0.3-2.5 Hz and 10.5-105.1 N/m, and intra-operator SEM ranged between 1.1-3.3 Hz and 21.9-144.1 N/m. The agreement of inter-operator was better than that of intra-operator. The study concluded that MyotonPRO is a reliable device to detect the tone and stiffness of quadriceps femoris and patellar tendon.https://doi.org/10.1371/journal.pone.0220521 |
spellingShingle | Guoqian Chen Jiatao Wu Guocai Chen Yanyan Lu Wei Ren Wu Xu Xuemeng Xu Zugui Wu Yingxin Guan Yi Zheng Bofan Qiu Reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles. PLoS ONE |
title | Reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles. |
title_full | Reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles. |
title_fullStr | Reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles. |
title_full_unstemmed | Reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles. |
title_short | Reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles. |
title_sort | reliability of a portable device for quantifying tone and stiffness of quadriceps femoris and patellar tendon at different knee flexion angles |
url | https://doi.org/10.1371/journal.pone.0220521 |
work_keys_str_mv | AT guoqianchen reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT jiataowu reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT guocaichen reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT yanyanlu reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT weiren reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT wuxu reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT xuemengxu reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT zuguiwu reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT yingxinguan reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT yizheng reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles AT bofanqiu reliabilityofaportabledeviceforquantifyingtoneandstiffnessofquadricepsfemorisandpatellartendonatdifferentkneeflexionangles |