Diagnostic value of multiparametric ultrasound and the EU-TIRADS system for differentiation of focal thyroid lesions

Background. Over the last 15 years, there have been many recommendations for the management of patients with thyroid nodules, based on the assessment of various ultrasound (US) criteria in B-mode. In 2020, the EU-TIRADS system (2017) was included in Russian Clinical Practice Guidelines. Shear wave e...

Full description

Bibliographic Details
Main Authors: A. V. Pomortsev, O. S. Tokarenko
Format: Article
Language:Russian
Published: Scientific Research Institute, Ochapovsky Regional Clinical Hospital no. 1 2020-09-01
Series:Инновационная медицина Кубани
Subjects:
Online Access:https://www.innovmedkub.ru/jour/article/view/292
_version_ 1797276872644493312
author A. V. Pomortsev
O. S. Tokarenko
author_facet A. V. Pomortsev
O. S. Tokarenko
author_sort A. V. Pomortsev
collection DOAJ
description Background. Over the last 15 years, there have been many recommendations for the management of patients with thyroid nodules, based on the assessment of various ultrasound (US) criteria in B-mode. In 2020, the EU-TIRADS system (2017) was included in Russian Clinical Practice Guidelines. Shear wave elastography (SWE) increases the diagnostic efficacy of ultrasonic B-mode examination of thyroid nodules and can be recommended to be included in the current classification system. Objective. The study aims to assess the diagnostic efficacy of multiparametric US combining SWE and color flow mapping in differentiating between benign and malignant thyroid nodules to define their stage according to the EU-TIRADS system and decide on the need for fine-needle aspiration biopsy. Material and Methods. A total of 150 thyroid nodules from 116 patients were analyzed. Lesions were then classified according to the EU-TIRADS system, SWE with an assessment of the color map and tissue stiffness was performed (Emean). In all tumors, cytological and histological (in operated patients) verification was carried out. Results. After B-mode US with color flow mapping, differentiation of palpable thyroid abnormalities by the EU-TIRADS system was carried out. 78 nodules were classified as EU-TIRADS 2 (52%), 42 as EU-TIRADS 3 (28%), 26 as EU-TIRADS 4 (17.3%), 4 as EU-TIRADS 5 (2.7%). On cytological examination 42 tumor nodules were detected. Of these, 6 (14.3%) cases were reported as papillary thyroid carcinoma, 36 (85.7%) as follicular neoplasm, 22 (61%) among the last prove to be follicular carcinoma. Qualitative and quantitative evaluation of elastograms was performed. Benign nodules were colored primarily in blue, while suspicious for malignancy revealed red areas of different size. Elasticity index in benign nodules was 24.3 ± 5.63 kPa for colloid goiter, 27.8 ± 6.35 kPa for cellular goiter; in suspicious for malignancy this index was 80.9 ± 50.9 kPa for follicular neoplasm, 114 ± 56.8 kPa for papillary thyroid cancer. The stiffness cutoff value for malignancy indicated with ROC-analysis was estimated as 45.4 kPa. Mean elasticity index (kPa) was significantly higher in suspicious for malignancy nodules than in benign nodules (р < 0.05). Of 120 (80%) nodules, primarily assessed as benign and defined as EU-TIRADS 2 and 3, 18 (12%) nodules after SWE revealed areas of high stiffness exceeding the cutoff value. After that, these nodules were transferred to EU-TIRADS 4 and 5, and these stages require fine-needle aspiration. Of these, 11 (7.3%) cases were reported as follicular neoplasm, 6 (4%) among the last prove to be follicular thyroid carcinoma. Conclusion. Using multiparametric approach with SWE will give the opportunity to classify correctly the nodule according to the EU-TIRADS and to identify greater number of thyroid tumors for fine-needle aspiration. SWE made it possible to increase the specificity of US using the EU-TIRADS system. The characteristics of the SWE score were: sensitivity = 81%, specificity = 90.3%, positive predictive value = 88%, negative predictive value = 91%, and accuracy of comprehensive study = 88.4%.
first_indexed 2024-03-07T15:35:34Z
format Article
id doaj.art-43ba4751d2b64faa9e6737ad75c1887a
institution Directory Open Access Journal
issn 2541-9897
language Russian
last_indexed 2024-03-07T15:35:34Z
publishDate 2020-09-01
publisher Scientific Research Institute, Ochapovsky Regional Clinical Hospital no. 1
record_format Article
series Инновационная медицина Кубани
spelling doaj.art-43ba4751d2b64faa9e6737ad75c1887a2024-03-05T11:12:30ZrusScientific Research Institute, Ochapovsky Regional Clinical Hospital no. 1Инновационная медицина Кубани2541-98972020-09-0103293710.35401/2500-0268-2020-19-3-29-37244Diagnostic value of multiparametric ultrasound and the EU-TIRADS system for differentiation of focal thyroid lesionsA. V. Pomortsev0O. S. Tokarenko1Kuban State Medical University; Regional Clinical Hospital no. 2Kuban State Medical University; Hospital of the Ministry of Internal Affairs of the Russian Federation in Krasnodar KraiBackground. Over the last 15 years, there have been many recommendations for the management of patients with thyroid nodules, based on the assessment of various ultrasound (US) criteria in B-mode. In 2020, the EU-TIRADS system (2017) was included in Russian Clinical Practice Guidelines. Shear wave elastography (SWE) increases the diagnostic efficacy of ultrasonic B-mode examination of thyroid nodules and can be recommended to be included in the current classification system. Objective. The study aims to assess the diagnostic efficacy of multiparametric US combining SWE and color flow mapping in differentiating between benign and malignant thyroid nodules to define their stage according to the EU-TIRADS system and decide on the need for fine-needle aspiration biopsy. Material and Methods. A total of 150 thyroid nodules from 116 patients were analyzed. Lesions were then classified according to the EU-TIRADS system, SWE with an assessment of the color map and tissue stiffness was performed (Emean). In all tumors, cytological and histological (in operated patients) verification was carried out. Results. After B-mode US with color flow mapping, differentiation of palpable thyroid abnormalities by the EU-TIRADS system was carried out. 78 nodules were classified as EU-TIRADS 2 (52%), 42 as EU-TIRADS 3 (28%), 26 as EU-TIRADS 4 (17.3%), 4 as EU-TIRADS 5 (2.7%). On cytological examination 42 tumor nodules were detected. Of these, 6 (14.3%) cases were reported as papillary thyroid carcinoma, 36 (85.7%) as follicular neoplasm, 22 (61%) among the last prove to be follicular carcinoma. Qualitative and quantitative evaluation of elastograms was performed. Benign nodules were colored primarily in blue, while suspicious for malignancy revealed red areas of different size. Elasticity index in benign nodules was 24.3 ± 5.63 kPa for colloid goiter, 27.8 ± 6.35 kPa for cellular goiter; in suspicious for malignancy this index was 80.9 ± 50.9 kPa for follicular neoplasm, 114 ± 56.8 kPa for papillary thyroid cancer. The stiffness cutoff value for malignancy indicated with ROC-analysis was estimated as 45.4 kPa. Mean elasticity index (kPa) was significantly higher in suspicious for malignancy nodules than in benign nodules (р < 0.05). Of 120 (80%) nodules, primarily assessed as benign and defined as EU-TIRADS 2 and 3, 18 (12%) nodules after SWE revealed areas of high stiffness exceeding the cutoff value. After that, these nodules were transferred to EU-TIRADS 4 and 5, and these stages require fine-needle aspiration. Of these, 11 (7.3%) cases were reported as follicular neoplasm, 6 (4%) among the last prove to be follicular thyroid carcinoma. Conclusion. Using multiparametric approach with SWE will give the opportunity to classify correctly the nodule according to the EU-TIRADS and to identify greater number of thyroid tumors for fine-needle aspiration. SWE made it possible to increase the specificity of US using the EU-TIRADS system. The characteristics of the SWE score were: sensitivity = 81%, specificity = 90.3%, positive predictive value = 88%, negative predictive value = 91%, and accuracy of comprehensive study = 88.4%.https://www.innovmedkub.ru/jour/article/view/292eu-tiradsshear wave elastographybenign thyroid nodulesthyroid cancer
spellingShingle A. V. Pomortsev
O. S. Tokarenko
Diagnostic value of multiparametric ultrasound and the EU-TIRADS system for differentiation of focal thyroid lesions
Инновационная медицина Кубани
eu-tirads
shear wave elastography
benign thyroid nodules
thyroid cancer
title Diagnostic value of multiparametric ultrasound and the EU-TIRADS system for differentiation of focal thyroid lesions
title_full Diagnostic value of multiparametric ultrasound and the EU-TIRADS system for differentiation of focal thyroid lesions
title_fullStr Diagnostic value of multiparametric ultrasound and the EU-TIRADS system for differentiation of focal thyroid lesions
title_full_unstemmed Diagnostic value of multiparametric ultrasound and the EU-TIRADS system for differentiation of focal thyroid lesions
title_short Diagnostic value of multiparametric ultrasound and the EU-TIRADS system for differentiation of focal thyroid lesions
title_sort diagnostic value of multiparametric ultrasound and the eu tirads system for differentiation of focal thyroid lesions
topic eu-tirads
shear wave elastography
benign thyroid nodules
thyroid cancer
url https://www.innovmedkub.ru/jour/article/view/292
work_keys_str_mv AT avpomortsev diagnosticvalueofmultiparametricultrasoundandtheeutiradssystemfordifferentiationoffocalthyroidlesions
AT ostokarenko diagnosticvalueofmultiparametricultrasoundandtheeutiradssystemfordifferentiationoffocalthyroidlesions