Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight hea...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2018-06-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/18/7/1980 |
_version_ | 1817996944223502336 |
---|---|
author | Wolfgang Teufl Markus Miezal Bertram Taetz Michael Fröhlich Gabriele Bleser |
author_facet | Wolfgang Teufl Markus Miezal Bertram Taetz Michael Fröhlich Gabriele Bleser |
author_sort | Wolfgang Teufl |
collection | DOAJ |
description | The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight healthy subjects performed a 6 min walk test. Three-dimensional joint kinematics of the lower extremity was recorded simultaneously by means of seven IMUs and an OptiTrack OMC system. To evaluate the performance, the root mean squared error (RMSE), mean range of motion error (ROME), coefficient of multiple correlations (CMC), Bland-Altman (BA) analysis, and intraclass correlation coefficient (ICC) were calculated. For all joints, the RMSE was lower than 2.40°, and the ROME was lower than 1.60°. The CMC revealed good to excellent waveform similarity. Reliability was moderate to excellent with ICC values of 0.52–0.99 for all joints. Error measures did not increase over time. When considering soft tissue artefacts, RMSE and ROME increased by an average of 2.2° ± 1.5° and 2.9° ± 1.7°. This study revealed an excellent correspondence of a magnetometer-free IMU system with an OMC system when excluding soft tissue artefacts. |
first_indexed | 2024-04-14T02:29:48Z |
format | Article |
id | doaj.art-44018e1249064bceac7f8c66e10f8412 |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-04-14T02:29:48Z |
publishDate | 2018-06-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-44018e1249064bceac7f8c66e10f84122022-12-22T02:17:42ZengMDPI AGSensors1424-82202018-06-01187198010.3390/s18071980s18071980Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint KinematicsWolfgang Teufl0Markus Miezal1Bertram Taetz2Michael Fröhlich3Gabriele Bleser4Junior Research Group wearHEALTH, Technische Universität Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, GermanyJunior Research Group wearHEALTH, Technische Universität Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, GermanyJunior Research Group wearHEALTH, Technische Universität Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, GermanyDepartment of Sports Science, Technische Universität Kaiserslautern, Erwin-Schrödinger-Str. 57, 67663 Kaiserslautern, GermanyJunior Research Group wearHEALTH, Technische Universität Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, GermanyThe present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight healthy subjects performed a 6 min walk test. Three-dimensional joint kinematics of the lower extremity was recorded simultaneously by means of seven IMUs and an OptiTrack OMC system. To evaluate the performance, the root mean squared error (RMSE), mean range of motion error (ROME), coefficient of multiple correlations (CMC), Bland-Altman (BA) analysis, and intraclass correlation coefficient (ICC) were calculated. For all joints, the RMSE was lower than 2.40°, and the ROME was lower than 1.60°. The CMC revealed good to excellent waveform similarity. Reliability was moderate to excellent with ICC values of 0.52–0.99 for all joints. Error measures did not increase over time. When considering soft tissue artefacts, RMSE and ROME increased by an average of 2.2° ± 1.5° and 2.9° ± 1.7°. This study revealed an excellent correspondence of a magnetometer-free IMU system with an OMC system when excluding soft tissue artefacts.http://www.mdpi.com/1424-8220/18/7/19803D joint kinematicsdriftinertial sensorsoft tissuetest-retest reliabilityvalidity |
spellingShingle | Wolfgang Teufl Markus Miezal Bertram Taetz Michael Fröhlich Gabriele Bleser Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics Sensors 3D joint kinematics drift inertial sensor soft tissue test-retest reliability validity |
title | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_full | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_fullStr | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_full_unstemmed | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_short | Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics |
title_sort | validity test retest reliability and long term stability of magnetometer free inertial sensor based 3d joint kinematics |
topic | 3D joint kinematics drift inertial sensor soft tissue test-retest reliability validity |
url | http://www.mdpi.com/1424-8220/18/7/1980 |
work_keys_str_mv | AT wolfgangteufl validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics AT markusmiezal validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics AT bertramtaetz validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics AT michaelfrohlich validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics AT gabrielebleser validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics |