Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics

The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight hea...

Full description

Bibliographic Details
Main Authors: Wolfgang Teufl, Markus Miezal, Bertram Taetz, Michael Fröhlich, Gabriele Bleser
Format: Article
Language:English
Published: MDPI AG 2018-06-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/18/7/1980
_version_ 1817996944223502336
author Wolfgang Teufl
Markus Miezal
Bertram Taetz
Michael Fröhlich
Gabriele Bleser
author_facet Wolfgang Teufl
Markus Miezal
Bertram Taetz
Michael Fröhlich
Gabriele Bleser
author_sort Wolfgang Teufl
collection DOAJ
description The present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight healthy subjects performed a 6 min walk test. Three-dimensional joint kinematics of the lower extremity was recorded simultaneously by means of seven IMUs and an OptiTrack OMC system. To evaluate the performance, the root mean squared error (RMSE), mean range of motion error (ROME), coefficient of multiple correlations (CMC), Bland-Altman (BA) analysis, and intraclass correlation coefficient (ICC) were calculated. For all joints, the RMSE was lower than 2.40°, and the ROME was lower than 1.60°. The CMC revealed good to excellent waveform similarity. Reliability was moderate to excellent with ICC values of 0.52–0.99 for all joints. Error measures did not increase over time. When considering soft tissue artefacts, RMSE and ROME increased by an average of 2.2° ± 1.5° and 2.9° ± 1.7°. This study revealed an excellent correspondence of a magnetometer-free IMU system with an OMC system when excluding soft tissue artefacts.
first_indexed 2024-04-14T02:29:48Z
format Article
id doaj.art-44018e1249064bceac7f8c66e10f8412
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-04-14T02:29:48Z
publishDate 2018-06-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-44018e1249064bceac7f8c66e10f84122022-12-22T02:17:42ZengMDPI AGSensors1424-82202018-06-01187198010.3390/s18071980s18071980Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint KinematicsWolfgang Teufl0Markus Miezal1Bertram Taetz2Michael Fröhlich3Gabriele Bleser4Junior Research Group wearHEALTH, Technische Universität Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, GermanyJunior Research Group wearHEALTH, Technische Universität Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, GermanyJunior Research Group wearHEALTH, Technische Universität Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, GermanyDepartment of Sports Science, Technische Universität Kaiserslautern, Erwin-Schrödinger-Str. 57, 67663 Kaiserslautern, GermanyJunior Research Group wearHEALTH, Technische Universität Kaiserslautern, Gottlieb-Daimler-Str. 48, 67663 Kaiserslautern, GermanyThe present study investigates an algorithm for the calculation of 3D joint angles based on inertial measurement units (IMUs), omitting magnetometer data. Validity, test-retest reliability, and long-term stability are evaluated in reference to an optical motion capture (OMC) system. Twenty-eight healthy subjects performed a 6 min walk test. Three-dimensional joint kinematics of the lower extremity was recorded simultaneously by means of seven IMUs and an OptiTrack OMC system. To evaluate the performance, the root mean squared error (RMSE), mean range of motion error (ROME), coefficient of multiple correlations (CMC), Bland-Altman (BA) analysis, and intraclass correlation coefficient (ICC) were calculated. For all joints, the RMSE was lower than 2.40°, and the ROME was lower than 1.60°. The CMC revealed good to excellent waveform similarity. Reliability was moderate to excellent with ICC values of 0.52–0.99 for all joints. Error measures did not increase over time. When considering soft tissue artefacts, RMSE and ROME increased by an average of 2.2° ± 1.5° and 2.9° ± 1.7°. This study revealed an excellent correspondence of a magnetometer-free IMU system with an OMC system when excluding soft tissue artefacts.http://www.mdpi.com/1424-8220/18/7/19803D joint kinematicsdriftinertial sensorsoft tissuetest-retest reliabilityvalidity
spellingShingle Wolfgang Teufl
Markus Miezal
Bertram Taetz
Michael Fröhlich
Gabriele Bleser
Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
Sensors
3D joint kinematics
drift
inertial sensor
soft tissue
test-retest reliability
validity
title Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_full Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_fullStr Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_full_unstemmed Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_short Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics
title_sort validity test retest reliability and long term stability of magnetometer free inertial sensor based 3d joint kinematics
topic 3D joint kinematics
drift
inertial sensor
soft tissue
test-retest reliability
validity
url http://www.mdpi.com/1424-8220/18/7/1980
work_keys_str_mv AT wolfgangteufl validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics
AT markusmiezal validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics
AT bertramtaetz validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics
AT michaelfrohlich validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics
AT gabrielebleser validitytestretestreliabilityandlongtermstabilityofmagnetometerfreeinertialsensorbased3djointkinematics