Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study

The paper considers the issue of the thermal refurbishment of residential buildings built between 10 and 40 years ago in some European countries. It suggests that, while facade retrofitting is the most effective solution for older dwellings, all actions are equally less effective for newer dwellings...

Full description

Bibliographic Details
Main Authors: Radoslav Ponechal, Jozef Jandačka, Pavol Ďurica
Format: Article
Language:English
Published: MDPI AG 2024-01-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/14/2/332
_version_ 1797298752637108224
author Radoslav Ponechal
Jozef Jandačka
Pavol Ďurica
author_facet Radoslav Ponechal
Jozef Jandačka
Pavol Ďurica
author_sort Radoslav Ponechal
collection DOAJ
description The paper considers the issue of the thermal refurbishment of residential buildings built between 10 and 40 years ago in some European countries. It suggests that, while facade retrofitting is the most effective solution for older dwellings, all actions are equally less effective for newer dwellings built in this millennium. According to the current situation, as society shifts away from the use of fossil fuels, this paper presents the expected energy and financial savings that were calculated using one of four different heating sources. The study shows that the efficiency of the additional thermal retrofitting of the structures is low when the building is heated with a heat pump. The addition of thermal insulation to already well-insulated roofs or floors results in minimal savings of approximately 0.15 kWh per square meter of heated floor area per year. The potential advantage of replacing existing windows with new windows in a top thermal quality was shown. After window replacement, the financial benefits could be twice as high in houses heated by district heating compared to houses heated by gas or a heat pump, including an alternative heat pump with photovoltaics.
first_indexed 2024-03-07T22:39:34Z
format Article
id doaj.art-4444baa9c10a416dbd10dd3ccedead1a
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-07T22:39:34Z
publishDate 2024-01-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-4444baa9c10a416dbd10dd3ccedead1a2024-02-23T15:09:56ZengMDPI AGBuildings2075-53092024-01-0114233210.3390/buildings14020332Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation StudyRadoslav Ponechal0Jozef Jandačka1Pavol Ďurica2Department of Building Engineering and Urban Planning, Faculty of Civil Engineering, University of Zilina, Univerzitna 8215/1, 010 26 Zilina, SlovakiaDepartment of Power Engineering, Faculty of Mechanical Engineering, University of Zilina, Univerzitna 8215/1, 010 26 Zilina, SlovakiaDepartment of Building Engineering and Urban Planning, Faculty of Civil Engineering, University of Zilina, Univerzitna 8215/1, 010 26 Zilina, SlovakiaThe paper considers the issue of the thermal refurbishment of residential buildings built between 10 and 40 years ago in some European countries. It suggests that, while facade retrofitting is the most effective solution for older dwellings, all actions are equally less effective for newer dwellings built in this millennium. According to the current situation, as society shifts away from the use of fossil fuels, this paper presents the expected energy and financial savings that were calculated using one of four different heating sources. The study shows that the efficiency of the additional thermal retrofitting of the structures is low when the building is heated with a heat pump. The addition of thermal insulation to already well-insulated roofs or floors results in minimal savings of approximately 0.15 kWh per square meter of heated floor area per year. The potential advantage of replacing existing windows with new windows in a top thermal quality was shown. After window replacement, the financial benefits could be twice as high in houses heated by district heating compared to houses heated by gas or a heat pump, including an alternative heat pump with photovoltaics.https://www.mdpi.com/2075-5309/14/2/332residential buildingthermal retrofittingenergy sourceenergy efficiency
spellingShingle Radoslav Ponechal
Jozef Jandačka
Pavol Ďurica
Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study
Buildings
residential building
thermal retrofitting
energy source
energy efficiency
title Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study
title_full Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study
title_fullStr Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study
title_full_unstemmed Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study
title_short Evaluation of Residential Buildings Savings for Various Envelope Retrofits and Heating Energy Sources: A Simulation Study
title_sort evaluation of residential buildings savings for various envelope retrofits and heating energy sources a simulation study
topic residential building
thermal retrofitting
energy source
energy efficiency
url https://www.mdpi.com/2075-5309/14/2/332
work_keys_str_mv AT radoslavponechal evaluationofresidentialbuildingssavingsforvariousenveloperetrofitsandheatingenergysourcesasimulationstudy
AT jozefjandacka evaluationofresidentialbuildingssavingsforvariousenveloperetrofitsandheatingenergysourcesasimulationstudy
AT pavoldurica evaluationofresidentialbuildingssavingsforvariousenveloperetrofitsandheatingenergysourcesasimulationstudy