Undetectable Macular Neovascularization on OCT Angiography in Age Related Macular Degeneration: Comparison between Different Devices

<i>Background and Objectives</i>: The aim of this study was to report the characteristics of macular neovascularization (MNV) with undetectable flow on optical coherence tomography angiography (OCTA) in neovascular age related macular degeneration (nAMD), and compare them with the charac...

Full description

Bibliographic Details
Main Authors: Meryem Filali Ansary, Emanuele Crincoli, Oudy Semoun, Joel Uzzan, Francesca Amoroso, Camille Jung, Alexandra Miere, Eric Souied
Format: Article
Language:English
Published: MDPI AG 2022-09-01
Series:Medicina
Subjects:
Online Access:https://www.mdpi.com/1648-9144/58/9/1246
_version_ 1797485002872586240
author Meryem Filali Ansary
Emanuele Crincoli
Oudy Semoun
Joel Uzzan
Francesca Amoroso
Camille Jung
Alexandra Miere
Eric Souied
author_facet Meryem Filali Ansary
Emanuele Crincoli
Oudy Semoun
Joel Uzzan
Francesca Amoroso
Camille Jung
Alexandra Miere
Eric Souied
author_sort Meryem Filali Ansary
collection DOAJ
description <i>Background and Objectives</i>: The aim of this study was to report the characteristics of macular neovascularization (MNV) with undetectable flow on optical coherence tomography angiography (OCTA) in neovascular age related macular degeneration (nAMD), and compare them with the characteristics of detectable MNV. <i>Materials and Methods</i>: Patients with a diagnosis of nAMD who underwent dye imaging and OCTA in the same day were included and divided into two groups: undetectable and detectable flow on OCTA. Three OCTA devices were used, two with spectral-domain technology (AngioVue, RTVue 100xAvanti, Optovue, Freemont, CA, USA and Heidelberg OCT2 Beta Angiography Module, Heidelberg Engineering, Germany) and one swept-source OCTA (PlexElite 9000; Carl Zeiss Meditec, Inc., Dublin, CA, USA). We studied the demographics, neovascularization characteristics, and OCTA device and acquisition characteristics for both groups. <i>Results</i>: A global comparison between Group 1 and Group 2 was made, followed by an analysis of variables associated with (un)detectability for each OCTA device. A total of 108 eyes were included: 90 in the detectable group (Group 1) and 18 in the undetectable group (Group 2), corresponding to a global sensitivity of OCTA for the detection of MNV of 83.49%. There was a statistically significant difference between the two groups regarding MNV type (<i>p</i> = 0.02) and PED height (<i>p</i> = 0.017). For the three devices, detection sensitivity with automatic segmentation was significantly lower than with manual segmentation. For Heidelberg, PED Height and scan quality explained 68.3% of the undetectability. For AngioVue, PED Height and absence of hemorrhage explained 67.9% of undetectability. <i>Conclusions</i>: In this study, we found a global sensitivity of 83.49% for the three OCTA devices combined, with a range from 55.5% to 96.26% depending on the segmentation and OCTA device. This means that undetectable/undetected MNV can represent up to 45% of the examinations, eventually misdiagnosing choroidal neovascularization for 1 out every 2 patients.
first_indexed 2024-03-09T23:13:32Z
format Article
id doaj.art-449e410ec27742308827d10231100797
institution Directory Open Access Journal
issn 1010-660X
1648-9144
language English
last_indexed 2024-03-09T23:13:32Z
publishDate 2022-09-01
publisher MDPI AG
record_format Article
series Medicina
spelling doaj.art-449e410ec27742308827d102311007972023-11-23T17:40:22ZengMDPI AGMedicina1010-660X1648-91442022-09-01589124610.3390/medicina58091246Undetectable Macular Neovascularization on OCT Angiography in Age Related Macular Degeneration: Comparison between Different DevicesMeryem Filali Ansary0Emanuele Crincoli1Oudy Semoun2Joel Uzzan3Francesca Amoroso4Camille Jung5Alexandra Miere6Eric Souied7Department of Ophthalmology, Creteil University Eye Clinic, Hopital Intercommunal de Creteil, University Paris Est, 40 Avenue de Verdun, 94010 Creteil, FranceDepartment of Ophthalmology, Creteil University Eye Clinic, Hopital Intercommunal de Creteil, University Paris Est, 40 Avenue de Verdun, 94010 Creteil, FranceDepartment of Ophthalmology, Creteil University Eye Clinic, Hopital Intercommunal de Creteil, University Paris Est, 40 Avenue de Verdun, 94010 Creteil, FranceDepartment of Ophthalmology, Creteil University Eye Clinic, Hopital Intercommunal de Creteil, University Paris Est, 40 Avenue de Verdun, 94010 Creteil, FranceDepartment of Ophthalmology, Creteil University Eye Clinic, Hopital Intercommunal de Creteil, University Paris Est, 40 Avenue de Verdun, 94010 Creteil, FranceCenter of Clinical Research, Centre Hospitalier Intercommunal de Créteil, 94010 Creteil, FranceDepartment of Ophthalmology, Creteil University Eye Clinic, Hopital Intercommunal de Creteil, University Paris Est, 40 Avenue de Verdun, 94010 Creteil, FranceDepartment of Ophthalmology, Creteil University Eye Clinic, Hopital Intercommunal de Creteil, University Paris Est, 40 Avenue de Verdun, 94010 Creteil, France<i>Background and Objectives</i>: The aim of this study was to report the characteristics of macular neovascularization (MNV) with undetectable flow on optical coherence tomography angiography (OCTA) in neovascular age related macular degeneration (nAMD), and compare them with the characteristics of detectable MNV. <i>Materials and Methods</i>: Patients with a diagnosis of nAMD who underwent dye imaging and OCTA in the same day were included and divided into two groups: undetectable and detectable flow on OCTA. Three OCTA devices were used, two with spectral-domain technology (AngioVue, RTVue 100xAvanti, Optovue, Freemont, CA, USA and Heidelberg OCT2 Beta Angiography Module, Heidelberg Engineering, Germany) and one swept-source OCTA (PlexElite 9000; Carl Zeiss Meditec, Inc., Dublin, CA, USA). We studied the demographics, neovascularization characteristics, and OCTA device and acquisition characteristics for both groups. <i>Results</i>: A global comparison between Group 1 and Group 2 was made, followed by an analysis of variables associated with (un)detectability for each OCTA device. A total of 108 eyes were included: 90 in the detectable group (Group 1) and 18 in the undetectable group (Group 2), corresponding to a global sensitivity of OCTA for the detection of MNV of 83.49%. There was a statistically significant difference between the two groups regarding MNV type (<i>p</i> = 0.02) and PED height (<i>p</i> = 0.017). For the three devices, detection sensitivity with automatic segmentation was significantly lower than with manual segmentation. For Heidelberg, PED Height and scan quality explained 68.3% of the undetectability. For AngioVue, PED Height and absence of hemorrhage explained 67.9% of undetectability. <i>Conclusions</i>: In this study, we found a global sensitivity of 83.49% for the three OCTA devices combined, with a range from 55.5% to 96.26% depending on the segmentation and OCTA device. This means that undetectable/undetected MNV can represent up to 45% of the examinations, eventually misdiagnosing choroidal neovascularization for 1 out every 2 patients.https://www.mdpi.com/1648-9144/58/9/1246optical coherence tomography (OCT)OCT-angiography (OCTA)macular neovascularizationspectral-domain OCTAswept-source OCTA
spellingShingle Meryem Filali Ansary
Emanuele Crincoli
Oudy Semoun
Joel Uzzan
Francesca Amoroso
Camille Jung
Alexandra Miere
Eric Souied
Undetectable Macular Neovascularization on OCT Angiography in Age Related Macular Degeneration: Comparison between Different Devices
Medicina
optical coherence tomography (OCT)
OCT-angiography (OCTA)
macular neovascularization
spectral-domain OCTA
swept-source OCTA
title Undetectable Macular Neovascularization on OCT Angiography in Age Related Macular Degeneration: Comparison between Different Devices
title_full Undetectable Macular Neovascularization on OCT Angiography in Age Related Macular Degeneration: Comparison between Different Devices
title_fullStr Undetectable Macular Neovascularization on OCT Angiography in Age Related Macular Degeneration: Comparison between Different Devices
title_full_unstemmed Undetectable Macular Neovascularization on OCT Angiography in Age Related Macular Degeneration: Comparison between Different Devices
title_short Undetectable Macular Neovascularization on OCT Angiography in Age Related Macular Degeneration: Comparison between Different Devices
title_sort undetectable macular neovascularization on oct angiography in age related macular degeneration comparison between different devices
topic optical coherence tomography (OCT)
OCT-angiography (OCTA)
macular neovascularization
spectral-domain OCTA
swept-source OCTA
url https://www.mdpi.com/1648-9144/58/9/1246
work_keys_str_mv AT meryemfilaliansary undetectablemacularneovascularizationonoctangiographyinagerelatedmaculardegenerationcomparisonbetweendifferentdevices
AT emanuelecrincoli undetectablemacularneovascularizationonoctangiographyinagerelatedmaculardegenerationcomparisonbetweendifferentdevices
AT oudysemoun undetectablemacularneovascularizationonoctangiographyinagerelatedmaculardegenerationcomparisonbetweendifferentdevices
AT joeluzzan undetectablemacularneovascularizationonoctangiographyinagerelatedmaculardegenerationcomparisonbetweendifferentdevices
AT francescaamoroso undetectablemacularneovascularizationonoctangiographyinagerelatedmaculardegenerationcomparisonbetweendifferentdevices
AT camillejung undetectablemacularneovascularizationonoctangiographyinagerelatedmaculardegenerationcomparisonbetweendifferentdevices
AT alexandramiere undetectablemacularneovascularizationonoctangiographyinagerelatedmaculardegenerationcomparisonbetweendifferentdevices
AT ericsouied undetectablemacularneovascularizationonoctangiographyinagerelatedmaculardegenerationcomparisonbetweendifferentdevices