Ratiometric Sensor Based on PtOEP-C6/Poly (St-TFEMA) Film for Automatic Dissolved Oxygen Content Detection
A ratiometric oxygen sensor based on a platinum octaethylporphyrin (PtOEP)–coumarin 6 (C6)/poly (styrene-trifluoroethyl methacrylate) (poly (St-TFEMA)) film was developed for automatic dissolved oxygen (DO) detection. The oxygen-sensing film according to the dynamic quenching mechanism was prepared...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-10-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/20/21/6175 |
_version_ | 1827703186600755200 |
---|---|
author | Honglin Zhang Zhiguo Zhang |
author_facet | Honglin Zhang Zhiguo Zhang |
author_sort | Honglin Zhang |
collection | DOAJ |
description | A ratiometric oxygen sensor based on a platinum octaethylporphyrin (PtOEP)–coumarin 6 (C6)/poly (styrene-trifluoroethyl methacrylate) (poly (St-TFEMA)) film was developed for automatic dissolved oxygen (DO) detection. The oxygen-sensing film according to the dynamic quenching mechanism was prepared by embedding platinum octaethylporphyrin (PtOEP) and coumarin 6 (C6) in poly (styrene-trifluoroethyl methacrylate) (poly (St-TFEMA)). The optical parameter (<i>OP</i>) was defined as the ratio of the oxygen-insensitive fluorescence from C6 to the oxygen-sensitive phosphorescence from PtOEP. A calibration equation expressing the correlation between the <i>OP</i> values and DO content described by a linear function was obtained. A program based on the Labview software was developed for monitoring the real-time DO content automatically. The influence of the excitation intensity and fluctuation on the <i>OP</i> values and the direct luminescence signal (integration areas) was compared, verifying the strong anti-interference ability of the sensor. The detection limit of the sensor was determined to be 0.10 (1) mg/L. The switching response time and recovery time of the sensor were 0.4 and 1.3 s, respectively. Finally, the oxygen sensor was applied to the investigation of the kinetic process of the DO content variation, which revealed an exponential relationship with time. |
first_indexed | 2024-03-10T15:13:45Z |
format | Article |
id | doaj.art-45601ab91f734f9b972b32c6942ff1d7 |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-03-10T15:13:45Z |
publishDate | 2020-10-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-45601ab91f734f9b972b32c6942ff1d72023-11-20T19:06:21ZengMDPI AGSensors1424-82202020-10-012021617510.3390/s20216175Ratiometric Sensor Based on PtOEP-C6/Poly (St-TFEMA) Film for Automatic Dissolved Oxygen Content DetectionHonglin Zhang0Zhiguo Zhang1School of physics, Harbin Institute of Technology, Harbin 150001, ChinaSchool of physics, Harbin Institute of Technology, Harbin 150001, ChinaA ratiometric oxygen sensor based on a platinum octaethylporphyrin (PtOEP)–coumarin 6 (C6)/poly (styrene-trifluoroethyl methacrylate) (poly (St-TFEMA)) film was developed for automatic dissolved oxygen (DO) detection. The oxygen-sensing film according to the dynamic quenching mechanism was prepared by embedding platinum octaethylporphyrin (PtOEP) and coumarin 6 (C6) in poly (styrene-trifluoroethyl methacrylate) (poly (St-TFEMA)). The optical parameter (<i>OP</i>) was defined as the ratio of the oxygen-insensitive fluorescence from C6 to the oxygen-sensitive phosphorescence from PtOEP. A calibration equation expressing the correlation between the <i>OP</i> values and DO content described by a linear function was obtained. A program based on the Labview software was developed for monitoring the real-time DO content automatically. The influence of the excitation intensity and fluctuation on the <i>OP</i> values and the direct luminescence signal (integration areas) was compared, verifying the strong anti-interference ability of the sensor. The detection limit of the sensor was determined to be 0.10 (1) mg/L. The switching response time and recovery time of the sensor were 0.4 and 1.3 s, respectively. Finally, the oxygen sensor was applied to the investigation of the kinetic process of the DO content variation, which revealed an exponential relationship with time.https://www.mdpi.com/1424-8220/20/21/6175ratiometric oxygen sensoroptical parameterdetection limitDO kinetic process |
spellingShingle | Honglin Zhang Zhiguo Zhang Ratiometric Sensor Based on PtOEP-C6/Poly (St-TFEMA) Film for Automatic Dissolved Oxygen Content Detection Sensors ratiometric oxygen sensor optical parameter detection limit DO kinetic process |
title | Ratiometric Sensor Based on PtOEP-C6/Poly (St-TFEMA) Film for Automatic Dissolved Oxygen Content Detection |
title_full | Ratiometric Sensor Based on PtOEP-C6/Poly (St-TFEMA) Film for Automatic Dissolved Oxygen Content Detection |
title_fullStr | Ratiometric Sensor Based on PtOEP-C6/Poly (St-TFEMA) Film for Automatic Dissolved Oxygen Content Detection |
title_full_unstemmed | Ratiometric Sensor Based on PtOEP-C6/Poly (St-TFEMA) Film for Automatic Dissolved Oxygen Content Detection |
title_short | Ratiometric Sensor Based on PtOEP-C6/Poly (St-TFEMA) Film for Automatic Dissolved Oxygen Content Detection |
title_sort | ratiometric sensor based on ptoep c6 poly st tfema film for automatic dissolved oxygen content detection |
topic | ratiometric oxygen sensor optical parameter detection limit DO kinetic process |
url | https://www.mdpi.com/1424-8220/20/21/6175 |
work_keys_str_mv | AT honglinzhang ratiometricsensorbasedonptoepc6polysttfemafilmforautomaticdissolvedoxygencontentdetection AT zhiguozhang ratiometricsensorbasedonptoepc6polysttfemafilmforautomaticdissolvedoxygencontentdetection |