CFD Analysis of Passive Autocatalytic Recombiner

In water-cooled nuclear power reactors, significant quantities of hydrogen could be produced following a postulated loss-of-coolant accident (LOCA) along with nonavailability of emergency core cooling system (ECCS). Passive autocatalytic recombiners (PAR) are implemented in the containment of water-...

Full description

Bibliographic Details
Main Authors: B. Gera, P. K. Sharma, R. K. Singh, K. K. Vaze
Format: Article
Language:English
Published: Hindawi Limited 2011-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2011/862812
Description
Summary:In water-cooled nuclear power reactors, significant quantities of hydrogen could be produced following a postulated loss-of-coolant accident (LOCA) along with nonavailability of emergency core cooling system (ECCS). Passive autocatalytic recombiners (PAR) are implemented in the containment of water-cooled power reactors to mitigate the risk of hydrogen combustion. In the presence of hydrogen with available oxygen, a catalytic reaction occurs spontaneously at the catalyst surfaces below conventional ignition concentration limits and temperature and even in presence of steam. Heat of reaction produces natural convection flow through the enclosure and promotes mixing in the containment. For the assessment of the PAR performance in terms of maximum temperature of catalyst surface and outlet hydrogen concentration an in-house 3D CFD model has been developed. The code has been used to study the mechanism of catalytic recombination and has been tested for two literature-quoted experiments.
ISSN:1687-6075