Ultrasound biomicroscopy in patients with unilateral pseudoexfoliation

<b>AIM:</b> To compare the anterior segment morphology evaluated using ultrasound biomicroscopy (UBM) in patients with clinical pseudoexfoliation syndrome (XFS) in one eye and no clinical XFS in the fellow eye.<b>METHODS:</b> Thirty patients with unilateral XFS were included...

Full description

Bibliographic Details
Main Authors: Erkan Ünsal, Kadir Eltutar, Ilkay Muftuoglu, Tulay Alpar Akcetin, Yıldız Acar
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2015-08-01
Series:International Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.cn/en_publish/2015/4/20150420.pdf
_version_ 1818941577884598272
author Erkan Ünsal
Kadir Eltutar
Ilkay Muftuoglu
Tulay Alpar Akcetin
Yıldız Acar
author_facet Erkan Ünsal
Kadir Eltutar
Ilkay Muftuoglu
Tulay Alpar Akcetin
Yıldız Acar
author_sort Erkan Ünsal
collection DOAJ
description <b>AIM:</b> To compare the anterior segment morphology evaluated using ultrasound biomicroscopy (UBM) in patients with clinical pseudoexfoliation syndrome (XFS) in one eye and no clinical XFS in the fellow eye.<b>METHODS:</b> Thirty patients with unilateral XFS were included in the study. All patients underwent evaluation of their anterior segment using UBM with and without dilatation with 1% cyclopentolate. The anterior chamber depth (ACD), lens thickness (LT), anterior chamber angle (ACA), ciliary body thickness (CBT), scleral thickness (ST), trabeculae -ciliary processes distance (T-CPD), and iris-ciliary processes distance (I-CPD) were measured using UBM scans. All results between the eyes with clinical XFS and their fellow eyes without clinical XFS were then compared.<b>RESULTS:</b> Before dilatation the eyes with XFS (4.350±0.531 mm) were found to have a significantly thicker lens (<i>P</i>=0.002) than the eyes without XFS (4.238±0.540 mm). In addition after dilatation, the eyes with XFS (4.310±0.500 mm) were found to have a significantly thicker lens than the eyes without XFS (4.160±0.480 mm) (<i>P</i>=0.019). The average ACD, for the group with XFS, comparing pre-dilatation (2.616±0.349 mm) and post-dilatation measurements (2.714±0.413) was found to be statistically increased (<i>P</i>=0.014). The average ACD, comparing pre-dilatation to post-dilatation measurements in patients without XFS (2.680±0.360), (2.720±0.500) was found to be statistically unchanged (<i>P</i>=0.450).<b>DISCUSSION:</b> Crystalline lenses tended to be thicker in the eyes with clinical pseudoexfoliation than their fellow eyes without pseudoexfoliation.
first_indexed 2024-12-20T06:57:45Z
format Article
id doaj.art-459489b673d84d859f731fbc2d59e80c
institution Directory Open Access Journal
issn 2222-3959
2227-4898
language English
last_indexed 2024-12-20T06:57:45Z
publishDate 2015-08-01
publisher Press of International Journal of Ophthalmology (IJO PRESS)
record_format Article
series International Journal of Ophthalmology
spelling doaj.art-459489b673d84d859f731fbc2d59e80c2022-12-21T19:49:17ZengPress of International Journal of Ophthalmology (IJO PRESS)International Journal of Ophthalmology2222-39592227-48982015-08-018475475810.3980/j.issn.2222-3959.2015.04.20Ultrasound biomicroscopy in patients with unilateral pseudoexfoliationErkan Ünsal0Kadir Eltutar1Ilkay Muftuoglu2Tulay Alpar Akcetin3Yıldız Acar4Department of Opthalmology, Istanbul Education and Research Hospital, Kasap Ilyas Mah, Org Abdurrahman Nafiz, Gurman Cd, Fatih, Istanbul 34098, TurkeyDepartment of Opthalmology, Istanbul Education and Research Hospital, Kasap Ilyas Mah, Org Abdurrahman Nafiz, Gurman Cd, Fatih, Istanbul 34098, TurkeyDepartment of Opthalmology, Istanbul Education and Research Hospital, Kasap Ilyas Mah, Org Abdurrahman Nafiz, Gurman Cd, Fatih, Istanbul 34098, TurkeyDepartment of Opthalmology, Istanbul Education and Research Hospital, Kasap Ilyas Mah, Org Abdurrahman Nafiz, Gurman Cd, Fatih, Istanbul 34098, TurkeyDepartment of Opthalmology, Istanbul Education and Research Hospital, Kasap Ilyas Mah, Org Abdurrahman Nafiz, Gurman Cd, Fatih, Istanbul 34098, Turkey<b>AIM:</b> To compare the anterior segment morphology evaluated using ultrasound biomicroscopy (UBM) in patients with clinical pseudoexfoliation syndrome (XFS) in one eye and no clinical XFS in the fellow eye.<b>METHODS:</b> Thirty patients with unilateral XFS were included in the study. All patients underwent evaluation of their anterior segment using UBM with and without dilatation with 1% cyclopentolate. The anterior chamber depth (ACD), lens thickness (LT), anterior chamber angle (ACA), ciliary body thickness (CBT), scleral thickness (ST), trabeculae -ciliary processes distance (T-CPD), and iris-ciliary processes distance (I-CPD) were measured using UBM scans. All results between the eyes with clinical XFS and their fellow eyes without clinical XFS were then compared.<b>RESULTS:</b> Before dilatation the eyes with XFS (4.350±0.531 mm) were found to have a significantly thicker lens (<i>P</i>=0.002) than the eyes without XFS (4.238±0.540 mm). In addition after dilatation, the eyes with XFS (4.310±0.500 mm) were found to have a significantly thicker lens than the eyes without XFS (4.160±0.480 mm) (<i>P</i>=0.019). The average ACD, for the group with XFS, comparing pre-dilatation (2.616±0.349 mm) and post-dilatation measurements (2.714±0.413) was found to be statistically increased (<i>P</i>=0.014). The average ACD, comparing pre-dilatation to post-dilatation measurements in patients without XFS (2.680±0.360), (2.720±0.500) was found to be statistically unchanged (<i>P</i>=0.450).<b>DISCUSSION:</b> Crystalline lenses tended to be thicker in the eyes with clinical pseudoexfoliation than their fellow eyes without pseudoexfoliation.http://www.ijo.cn/en_publish/2015/4/20150420.pdfpseudoexfoliation syndromeultrasonic biomicroscopyanterior segment morphology
spellingShingle Erkan Ünsal
Kadir Eltutar
Ilkay Muftuoglu
Tulay Alpar Akcetin
Yıldız Acar
Ultrasound biomicroscopy in patients with unilateral pseudoexfoliation
International Journal of Ophthalmology
pseudoexfoliation syndrome
ultrasonic biomicroscopy
anterior segment morphology
title Ultrasound biomicroscopy in patients with unilateral pseudoexfoliation
title_full Ultrasound biomicroscopy in patients with unilateral pseudoexfoliation
title_fullStr Ultrasound biomicroscopy in patients with unilateral pseudoexfoliation
title_full_unstemmed Ultrasound biomicroscopy in patients with unilateral pseudoexfoliation
title_short Ultrasound biomicroscopy in patients with unilateral pseudoexfoliation
title_sort ultrasound biomicroscopy in patients with unilateral pseudoexfoliation
topic pseudoexfoliation syndrome
ultrasonic biomicroscopy
anterior segment morphology
url http://www.ijo.cn/en_publish/2015/4/20150420.pdf
work_keys_str_mv AT erkanunsal ultrasoundbiomicroscopyinpatientswithunilateralpseudoexfoliation
AT kadireltutar ultrasoundbiomicroscopyinpatientswithunilateralpseudoexfoliation
AT ilkaymuftuoglu ultrasoundbiomicroscopyinpatientswithunilateralpseudoexfoliation
AT tulayalparakcetin ultrasoundbiomicroscopyinpatientswithunilateralpseudoexfoliation
AT yıldızacar ultrasoundbiomicroscopyinpatientswithunilateralpseudoexfoliation