An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)
Purpose: We aimed to determine whether Descemet's membrane (DM) scrolling occurs primarily along the vertical or horizontal axis and establish whether oval trephination along the axis of least scrolling can reduce the grade of the scroll. Methods: The longest limbus-to-limbus axis on 28 scleroc...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2023-01-01
|
Series: | Indian Journal of Ophthalmology |
Subjects: | |
Online Access: | http://www.ijo.in/article.asp?issn=0301-4738;year=2023;volume=71;issue=9;spage=3178;epage=3185;aulast=Dua |
_version_ | 1797649288978759680 |
---|---|
author | Harminder S Dua Rui Freitas Youssef Sadek Darren S J Ting Mario Nubile Imran Mohammed Dalia G Said |
author_facet | Harminder S Dua Rui Freitas Youssef Sadek Darren S J Ting Mario Nubile Imran Mohammed Dalia G Said |
author_sort | Harminder S Dua |
collection | DOAJ |
description | Purpose: We aimed to determine whether Descemet's membrane (DM) scrolling occurs primarily along the vertical or horizontal axis and establish whether oval trephination along the axis of least scrolling can reduce the grade of the scroll. Methods: The longest limbus-to-limbus axis on 28 sclerocorneal discs was taken as the horizontal axis. The horizontal (n = 7) or (right angles to it) vertical (n = 6) axis was marked on DM before peeling it off. The direction and grade of scrolling was observed. Narrow strips (3–4 mm wide) were then cut along the two axes (n = 4 each) and the scrolling pattern was observed. Ellipses (7 × 9 mm) of DM were punched along the two axes (n = 6 each) and the scrolls graded. Immunofluorescent staining for elastin on horizontal and vertical tissue sections from three DM samples was performed. The intensity and thickness of elastin staining were measured. Results: Twenty-four (85.72%) DM samples showed scrolling along the horizontal axis, none showed scrolling along the vertical axis, and four (14.28%) samples showed a spiral scroll, regardless of which axis was marked (grade 3.7 and 3.6). Vertically oval discs showed significantly reduced scrolling (grade 1.2) compared to horizontally oval discs (grade 3.5). Narrow strips of DM showed a similar scrolling pattern. Immunohistology showed no difference in any of the parameters examined along the two axes or from the center to the periphery. Conclusion: DM scrolls primarily along the horizontal axis. Vertically oval DM samples show minimal scrolling, which can be an advantage in DMEK. Differential scrolling is not determined by the distribution of elastin. |
first_indexed | 2024-03-11T15:45:01Z |
format | Article |
id | doaj.art-45bf4053cddb4bbf95c0d315b6a8d0dc |
institution | Directory Open Access Journal |
issn | 0301-4738 1998-3689 |
language | English |
last_indexed | 2024-03-11T15:45:01Z |
publishDate | 2023-01-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Indian Journal of Ophthalmology |
spelling | doaj.art-45bf4053cddb4bbf95c0d315b6a8d0dc2023-10-26T06:49:21ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892023-01-017193178318510.4103/IJO.IJO_1531_23An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)Harminder S DuaRui FreitasYoussef SadekDarren S J TingMario NubileImran MohammedDalia G SaidPurpose: We aimed to determine whether Descemet's membrane (DM) scrolling occurs primarily along the vertical or horizontal axis and establish whether oval trephination along the axis of least scrolling can reduce the grade of the scroll. Methods: The longest limbus-to-limbus axis on 28 sclerocorneal discs was taken as the horizontal axis. The horizontal (n = 7) or (right angles to it) vertical (n = 6) axis was marked on DM before peeling it off. The direction and grade of scrolling was observed. Narrow strips (3–4 mm wide) were then cut along the two axes (n = 4 each) and the scrolling pattern was observed. Ellipses (7 × 9 mm) of DM were punched along the two axes (n = 6 each) and the scrolls graded. Immunofluorescent staining for elastin on horizontal and vertical tissue sections from three DM samples was performed. The intensity and thickness of elastin staining were measured. Results: Twenty-four (85.72%) DM samples showed scrolling along the horizontal axis, none showed scrolling along the vertical axis, and four (14.28%) samples showed a spiral scroll, regardless of which axis was marked (grade 3.7 and 3.6). Vertically oval discs showed significantly reduced scrolling (grade 1.2) compared to horizontally oval discs (grade 3.5). Narrow strips of DM showed a similar scrolling pattern. Immunohistology showed no difference in any of the parameters examined along the two axes or from the center to the periphery. Conclusion: DM scrolls primarily along the horizontal axis. Vertically oval DM samples show minimal scrolling, which can be an advantage in DMEK. Differential scrolling is not determined by the distribution of elastin.http://www.ijo.in/article.asp?issn=0301-4738;year=2023;volume=71;issue=9;spage=3178;epage=3185;aulast=Duadescemet's membranedmekendothelial keratoplastyscrolling |
spellingShingle | Harminder S Dua Rui Freitas Youssef Sadek Darren S J Ting Mario Nubile Imran Mohammed Dalia G Said An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK) Indian Journal of Ophthalmology descemet's membrane dmek endothelial keratoplasty scrolling |
title | An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK) |
title_full | An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK) |
title_fullStr | An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK) |
title_full_unstemmed | An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK) |
title_short | An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK) |
title_sort | approach to reduce descemet s membrane scrolling relevance to descemet s membrane endothelial keratoplasty dmek |
topic | descemet's membrane dmek endothelial keratoplasty scrolling |
url | http://www.ijo.in/article.asp?issn=0301-4738;year=2023;volume=71;issue=9;spage=3178;epage=3185;aulast=Dua |
work_keys_str_mv | AT harmindersdua anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT ruifreitas anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT youssefsadek anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT darrensjting anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT marionubile anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT imranmohammed anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT daliagsaid anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT harmindersdua approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT ruifreitas approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT youssefsadek approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT darrensjting approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT marionubile approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT imranmohammed approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT daliagsaid approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek |