An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)

Purpose: We aimed to determine whether Descemet's membrane (DM) scrolling occurs primarily along the vertical or horizontal axis and establish whether oval trephination along the axis of least scrolling can reduce the grade of the scroll. Methods: The longest limbus-to-limbus axis on 28 scleroc...

Full description

Bibliographic Details
Main Authors: Harminder S Dua, Rui Freitas, Youssef Sadek, Darren S J Ting, Mario Nubile, Imran Mohammed, Dalia G Said
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2023-01-01
Series:Indian Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.in/article.asp?issn=0301-4738;year=2023;volume=71;issue=9;spage=3178;epage=3185;aulast=Dua
_version_ 1797649288978759680
author Harminder S Dua
Rui Freitas
Youssef Sadek
Darren S J Ting
Mario Nubile
Imran Mohammed
Dalia G Said
author_facet Harminder S Dua
Rui Freitas
Youssef Sadek
Darren S J Ting
Mario Nubile
Imran Mohammed
Dalia G Said
author_sort Harminder S Dua
collection DOAJ
description Purpose: We aimed to determine whether Descemet's membrane (DM) scrolling occurs primarily along the vertical or horizontal axis and establish whether oval trephination along the axis of least scrolling can reduce the grade of the scroll. Methods: The longest limbus-to-limbus axis on 28 sclerocorneal discs was taken as the horizontal axis. The horizontal (n = 7) or (right angles to it) vertical (n = 6) axis was marked on DM before peeling it off. The direction and grade of scrolling was observed. Narrow strips (3–4 mm wide) were then cut along the two axes (n = 4 each) and the scrolling pattern was observed. Ellipses (7 × 9 mm) of DM were punched along the two axes (n = 6 each) and the scrolls graded. Immunofluorescent staining for elastin on horizontal and vertical tissue sections from three DM samples was performed. The intensity and thickness of elastin staining were measured. Results: Twenty-four (85.72%) DM samples showed scrolling along the horizontal axis, none showed scrolling along the vertical axis, and four (14.28%) samples showed a spiral scroll, regardless of which axis was marked (grade 3.7 and 3.6). Vertically oval discs showed significantly reduced scrolling (grade 1.2) compared to horizontally oval discs (grade 3.5). Narrow strips of DM showed a similar scrolling pattern. Immunohistology showed no difference in any of the parameters examined along the two axes or from the center to the periphery. Conclusion: DM scrolls primarily along the horizontal axis. Vertically oval DM samples show minimal scrolling, which can be an advantage in DMEK. Differential scrolling is not determined by the distribution of elastin.
first_indexed 2024-03-11T15:45:01Z
format Article
id doaj.art-45bf4053cddb4bbf95c0d315b6a8d0dc
institution Directory Open Access Journal
issn 0301-4738
1998-3689
language English
last_indexed 2024-03-11T15:45:01Z
publishDate 2023-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Ophthalmology
spelling doaj.art-45bf4053cddb4bbf95c0d315b6a8d0dc2023-10-26T06:49:21ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892023-01-017193178318510.4103/IJO.IJO_1531_23An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)Harminder S DuaRui FreitasYoussef SadekDarren S J TingMario NubileImran MohammedDalia G SaidPurpose: We aimed to determine whether Descemet's membrane (DM) scrolling occurs primarily along the vertical or horizontal axis and establish whether oval trephination along the axis of least scrolling can reduce the grade of the scroll. Methods: The longest limbus-to-limbus axis on 28 sclerocorneal discs was taken as the horizontal axis. The horizontal (n = 7) or (right angles to it) vertical (n = 6) axis was marked on DM before peeling it off. The direction and grade of scrolling was observed. Narrow strips (3–4 mm wide) were then cut along the two axes (n = 4 each) and the scrolling pattern was observed. Ellipses (7 × 9 mm) of DM were punched along the two axes (n = 6 each) and the scrolls graded. Immunofluorescent staining for elastin on horizontal and vertical tissue sections from three DM samples was performed. The intensity and thickness of elastin staining were measured. Results: Twenty-four (85.72%) DM samples showed scrolling along the horizontal axis, none showed scrolling along the vertical axis, and four (14.28%) samples showed a spiral scroll, regardless of which axis was marked (grade 3.7 and 3.6). Vertically oval discs showed significantly reduced scrolling (grade 1.2) compared to horizontally oval discs (grade 3.5). Narrow strips of DM showed a similar scrolling pattern. Immunohistology showed no difference in any of the parameters examined along the two axes or from the center to the periphery. Conclusion: DM scrolls primarily along the horizontal axis. Vertically oval DM samples show minimal scrolling, which can be an advantage in DMEK. Differential scrolling is not determined by the distribution of elastin.http://www.ijo.in/article.asp?issn=0301-4738;year=2023;volume=71;issue=9;spage=3178;epage=3185;aulast=Duadescemet's membranedmekendothelial keratoplastyscrolling
spellingShingle Harminder S Dua
Rui Freitas
Youssef Sadek
Darren S J Ting
Mario Nubile
Imran Mohammed
Dalia G Said
An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)
Indian Journal of Ophthalmology
descemet's membrane
dmek
endothelial keratoplasty
scrolling
title An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)
title_full An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)
title_fullStr An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)
title_full_unstemmed An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)
title_short An approach to reduce Descemet's membrane scrolling: Relevance to Descemet's membrane endothelial keratoplasty (DMEK)
title_sort approach to reduce descemet s membrane scrolling relevance to descemet s membrane endothelial keratoplasty dmek
topic descemet's membrane
dmek
endothelial keratoplasty
scrolling
url http://www.ijo.in/article.asp?issn=0301-4738;year=2023;volume=71;issue=9;spage=3178;epage=3185;aulast=Dua
work_keys_str_mv AT harmindersdua anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT ruifreitas anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT youssefsadek anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT darrensjting anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT marionubile anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT imranmohammed anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT daliagsaid anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT harmindersdua approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT ruifreitas approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT youssefsadek approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT darrensjting approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT marionubile approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT imranmohammed approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek
AT daliagsaid approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek