Assessment of Effective Dose Associated with Coronary Computed Tomography Angiography in Isfahan Province, Iran

Computed tomography coronary angiography (CTCA) has generated a great interest over the past two decades, due to its high diagnostic accuracy and efficacy in the assessment of patients having coronary artery disease. This method is associated with high radiation dose and this has raised serious conc...

Full description

Bibliographic Details
Main Authors: Mohammadbagher Tavakoli, Reihane Faraji, Zahra Alirezaei, Zohre Nateghian
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2018-01-01
Series:Journal of Medical Signals and Sensors
Subjects:
Online Access:http://www.jmss.mui.ac.ir/article.asp?issn=2228-7477;year=2018;volume=8;issue=1;spage=60;epage=64;aulast=Tavakoli
_version_ 1818508027011006464
author Mohammadbagher Tavakoli
Reihane Faraji
Zahra Alirezaei
Zohre Nateghian
author_facet Mohammadbagher Tavakoli
Reihane Faraji
Zahra Alirezaei
Zohre Nateghian
author_sort Mohammadbagher Tavakoli
collection DOAJ
description Computed tomography coronary angiography (CTCA) has generated a great interest over the past two decades, due to its high diagnostic accuracy and efficacy in the assessment of patients having coronary artery disease. This method is associated with high radiation dose and this has raised serious concerns in the literature. Effective dose (E) is a single parameter meant to reflect the relative risk from exposure to ionizing radiation. Therefore, it is necessary to calculate this parameter to indicate ionizing radiation relative risk. The aim of this study was to calculate the effective dose from 64-slice CTCA in Isfahan. To calculate the effective dose, an ionization chamber and a body phantom with diameter of 32 cm and length of 15 cm were used. CTCA radiation conditions commonly used in two centers were applied for this work. For all scans, computed tomography volume dose index (CTDIv), dose-length product (DLP), and effective dose were obtained using dose-length-product method. The obtained CTDIv, DLP, and effective dose were compared in two centers, and mean, maximum, and minimum values of effective dose for heart coronary CT angiography (CCTA) examinations and calcium score were compared with other studies. The amount of average, maximum, and minimum effective doses for heart CCTA examinations in two centers are 4.65 ± 0.06, 6.0489, and 3.492 mSv, respectively, and for calcium score test are, 1.04 ± 0.04, 2.155, and 0.98 mSv, respectively. CTDIv, DLP, and effective dose values did not show any significant difference in two centers. Although the effective dose of CTCA and calcium score was lower than that of other studies, it is reasonable to reduce the effective dose to the minimum possible value to reduce the risk of cancer associated with ionizing radiation. The results of this study can be used to introduce the effective dose as a local diagnostic reference dose (DRL) for CTCA examinations in Isfahan Province.
first_indexed 2024-12-10T22:26:13Z
format Article
id doaj.art-4615fff66c5b4912ba7115223e8143a6
institution Directory Open Access Journal
issn 2228-7477
language English
last_indexed 2024-12-10T22:26:13Z
publishDate 2018-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Signals and Sensors
spelling doaj.art-4615fff66c5b4912ba7115223e8143a62022-12-22T01:31:11ZengWolters Kluwer Medknow PublicationsJournal of Medical Signals and Sensors2228-74772018-01-01816064Assessment of Effective Dose Associated with Coronary Computed Tomography Angiography in Isfahan Province, IranMohammadbagher TavakoliReihane FarajiZahra AlirezaeiZohre NateghianComputed tomography coronary angiography (CTCA) has generated a great interest over the past two decades, due to its high diagnostic accuracy and efficacy in the assessment of patients having coronary artery disease. This method is associated with high radiation dose and this has raised serious concerns in the literature. Effective dose (E) is a single parameter meant to reflect the relative risk from exposure to ionizing radiation. Therefore, it is necessary to calculate this parameter to indicate ionizing radiation relative risk. The aim of this study was to calculate the effective dose from 64-slice CTCA in Isfahan. To calculate the effective dose, an ionization chamber and a body phantom with diameter of 32 cm and length of 15 cm were used. CTCA radiation conditions commonly used in two centers were applied for this work. For all scans, computed tomography volume dose index (CTDIv), dose-length product (DLP), and effective dose were obtained using dose-length-product method. The obtained CTDIv, DLP, and effective dose were compared in two centers, and mean, maximum, and minimum values of effective dose for heart coronary CT angiography (CCTA) examinations and calcium score were compared with other studies. The amount of average, maximum, and minimum effective doses for heart CCTA examinations in two centers are 4.65 ± 0.06, 6.0489, and 3.492 mSv, respectively, and for calcium score test are, 1.04 ± 0.04, 2.155, and 0.98 mSv, respectively. CTDIv, DLP, and effective dose values did not show any significant difference in two centers. Although the effective dose of CTCA and calcium score was lower than that of other studies, it is reasonable to reduce the effective dose to the minimum possible value to reduce the risk of cancer associated with ionizing radiation. The results of this study can be used to introduce the effective dose as a local diagnostic reference dose (DRL) for CTCA examinations in Isfahan Province.http://www.jmss.mui.ac.ir/article.asp?issn=2228-7477;year=2018;volume=8;issue=1;spage=60;epage=64;aulast=TavakoliComputed tomography volume dose indexcoronary computed tomography angiographydose length producteffective doselocal diagnostic reference dosemultidetector computed tomography scan
spellingShingle Mohammadbagher Tavakoli
Reihane Faraji
Zahra Alirezaei
Zohre Nateghian
Assessment of Effective Dose Associated with Coronary Computed Tomography Angiography in Isfahan Province, Iran
Journal of Medical Signals and Sensors
Computed tomography volume dose index
coronary computed tomography angiography
dose length product
effective dose
local diagnostic reference dose
multidetector computed tomography scan
title Assessment of Effective Dose Associated with Coronary Computed Tomography Angiography in Isfahan Province, Iran
title_full Assessment of Effective Dose Associated with Coronary Computed Tomography Angiography in Isfahan Province, Iran
title_fullStr Assessment of Effective Dose Associated with Coronary Computed Tomography Angiography in Isfahan Province, Iran
title_full_unstemmed Assessment of Effective Dose Associated with Coronary Computed Tomography Angiography in Isfahan Province, Iran
title_short Assessment of Effective Dose Associated with Coronary Computed Tomography Angiography in Isfahan Province, Iran
title_sort assessment of effective dose associated with coronary computed tomography angiography in isfahan province iran
topic Computed tomography volume dose index
coronary computed tomography angiography
dose length product
effective dose
local diagnostic reference dose
multidetector computed tomography scan
url http://www.jmss.mui.ac.ir/article.asp?issn=2228-7477;year=2018;volume=8;issue=1;spage=60;epage=64;aulast=Tavakoli
work_keys_str_mv AT mohammadbaghertavakoli assessmentofeffectivedoseassociatedwithcoronarycomputedtomographyangiographyinisfahanprovinceiran
AT reihanefaraji assessmentofeffectivedoseassociatedwithcoronarycomputedtomographyangiographyinisfahanprovinceiran
AT zahraalirezaei assessmentofeffectivedoseassociatedwithcoronarycomputedtomographyangiographyinisfahanprovinceiran
AT zohrenateghian assessmentofeffectivedoseassociatedwithcoronarycomputedtomographyangiographyinisfahanprovinceiran