Shear bond strength of self-etch and total-etch bonding systems at different dentin depths

The purpose of this study was to evaluate the dentin shear bond strength of four adhesive systems (Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond) in regards to buccal and lingual surfaces and dentin depth. Forty extracted third molars had roots removed and crowns bisected...

Full description

Bibliographic Details
Main Authors: Ana Carolina Maito Villela-Rosa, Mariane Gonçalves, Iara Augusta Orsi, Paola Kirsten Miani
Format: Article
Language:English
Published: Sociedade Brasileira de Pesquisa Odontológica 2011-04-01
Series:Brazilian Oral Research
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242011000200003
_version_ 1811331210634330112
author Ana Carolina Maito Villela-Rosa
Mariane Gonçalves
Iara Augusta Orsi
Paola Kirsten Miani
author_facet Ana Carolina Maito Villela-Rosa
Mariane Gonçalves
Iara Augusta Orsi
Paola Kirsten Miani
author_sort Ana Carolina Maito Villela-Rosa
collection DOAJ
description The purpose of this study was to evaluate the dentin shear bond strength of four adhesive systems (Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond) in regards to buccal and lingual surfaces and dentin depth. Forty extracted third molars had roots removed and crowns bisected in the mesiodistal direction. The buccal and lingual surfaces were fixed in a PVC/acrylic resin ring and were divided into buccal and lingual groups assigned to each selected adhesive. The same specimens prepared for the evaluation of superficial dentin shear resistance were used to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0 mm. Each depth was evaluated by ISO TR 11405 using an EMIC-2000 machine regulated at 0.5 mm/min with a 200 Kgf load cell. We performed statistical analyses on the results (ANOVA, Tukey and Scheffé tests). Data revealed statistical differences (p < 0.01) in the adhesive and depth variation as well as adhesive/depth interactions. The Adper Single Bond 2 demonstrated the highest mean values of shear bond strength. The Prompt L-Pop product, a self-etching adhesive, revealed higher mean values compared with Magic Bond DE and Self Etch Bond adhesives, a total and self-etching adhesive respectively. It may be concluded that the shear bond strength of dentin is dependent on material (adhesive system), substrate depth and adhesive/depth interaction.
first_indexed 2024-04-13T16:17:03Z
format Article
id doaj.art-466c8d4b1d72467fb948ab4572505c0e
institution Directory Open Access Journal
issn 1806-8324
language English
last_indexed 2024-04-13T16:17:03Z
publishDate 2011-04-01
publisher Sociedade Brasileira de Pesquisa Odontológica
record_format Article
series Brazilian Oral Research
spelling doaj.art-466c8d4b1d72467fb948ab4572505c0e2022-12-22T02:40:02ZengSociedade Brasileira de Pesquisa OdontológicaBrazilian Oral Research1806-83242011-04-01252143149Shear bond strength of self-etch and total-etch bonding systems at different dentin depthsAna Carolina Maito Villela-RosaMariane GonçalvesIara Augusta OrsiPaola Kirsten MianiThe purpose of this study was to evaluate the dentin shear bond strength of four adhesive systems (Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond) in regards to buccal and lingual surfaces and dentin depth. Forty extracted third molars had roots removed and crowns bisected in the mesiodistal direction. The buccal and lingual surfaces were fixed in a PVC/acrylic resin ring and were divided into buccal and lingual groups assigned to each selected adhesive. The same specimens prepared for the evaluation of superficial dentin shear resistance were used to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0 mm. Each depth was evaluated by ISO TR 11405 using an EMIC-2000 machine regulated at 0.5 mm/min with a 200 Kgf load cell. We performed statistical analyses on the results (ANOVA, Tukey and Scheffé tests). Data revealed statistical differences (p < 0.01) in the adhesive and depth variation as well as adhesive/depth interactions. The Adper Single Bond 2 demonstrated the highest mean values of shear bond strength. The Prompt L-Pop product, a self-etching adhesive, revealed higher mean values compared with Magic Bond DE and Self Etch Bond adhesives, a total and self-etching adhesive respectively. It may be concluded that the shear bond strength of dentin is dependent on material (adhesive system), substrate depth and adhesive/depth interaction.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242011000200003DentinAdhesivesDental Etching
spellingShingle Ana Carolina Maito Villela-Rosa
Mariane Gonçalves
Iara Augusta Orsi
Paola Kirsten Miani
Shear bond strength of self-etch and total-etch bonding systems at different dentin depths
Brazilian Oral Research
Dentin
Adhesives
Dental Etching
title Shear bond strength of self-etch and total-etch bonding systems at different dentin depths
title_full Shear bond strength of self-etch and total-etch bonding systems at different dentin depths
title_fullStr Shear bond strength of self-etch and total-etch bonding systems at different dentin depths
title_full_unstemmed Shear bond strength of self-etch and total-etch bonding systems at different dentin depths
title_short Shear bond strength of self-etch and total-etch bonding systems at different dentin depths
title_sort shear bond strength of self etch and total etch bonding systems at different dentin depths
topic Dentin
Adhesives
Dental Etching
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242011000200003
work_keys_str_mv AT anacarolinamaitovillelarosa shearbondstrengthofselfetchandtotaletchbondingsystemsatdifferentdentindepths
AT marianegoncalves shearbondstrengthofselfetchandtotaletchbondingsystemsatdifferentdentindepths
AT iaraaugustaorsi shearbondstrengthofselfetchandtotaletchbondingsystemsatdifferentdentindepths
AT paolakirstenmiani shearbondstrengthofselfetchandtotaletchbondingsystemsatdifferentdentindepths