Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fractures

Introduction: Lag screw cut-out is a serious complication of dynamic hip screw fixation of trochanteric hip fractures. The lag screw position has been acknowledged as one of the important factors affecting the lag screw cut-out. We propose a modification of the Tip Apex Distance (TAD) and hypothesis...

Full description

Bibliographic Details
Main Authors: Selim Amr, Al-Hadithy Nawfal, Diab Nader M., Ahmed Abdulla Mohamed, Kader Khaled Fawzy Abdel, Hegazy Mohamed, Azeem Hazem Abdel, Barakat Ahmed Samir
Format: Article
Language:English
Published: EDP Sciences 2023-01-01
Series:SICOT-J
Subjects:
Online Access:https://www.sicot-j.org/articles/sicotj/full_html/2023/01/sicotj230053/sicotj230053.html
_version_ 1797673432554405888
author Selim Amr
Al-Hadithy Nawfal
Diab Nader M.
Ahmed Abdulla Mohamed
Kader Khaled Fawzy Abdel
Hegazy Mohamed
Azeem Hazem Abdel
Barakat Ahmed Samir
author_facet Selim Amr
Al-Hadithy Nawfal
Diab Nader M.
Ahmed Abdulla Mohamed
Kader Khaled Fawzy Abdel
Hegazy Mohamed
Azeem Hazem Abdel
Barakat Ahmed Samir
author_sort Selim Amr
collection DOAJ
description Introduction: Lag screw cut-out is a serious complication of dynamic hip screw fixation of trochanteric hip fractures. The lag screw position has been acknowledged as one of the important factors affecting the lag screw cut-out. We propose a modification of the Tip Apex Distance (TAD) and hypothesise that it could improve the reliability of predicting lag screws cut-out in these injuries. Materials and Methods: A retrospective study was conducted for hip fracture entries in the period from Jan 2018 to July 2022. A hundred and nine patients were suitable for the final analysis. The modified TAD was measured in millimetres based on the sum of the traditional TAD in the lateral view and the net value of two distances in the AP view, the first distance is from the tip of the lag screw to the opposite point on the femoral head along the axis of the lag screw while the second distance is from that point to the femoral head apex. The first distance is a positive value, whereas the second distance is positive if the lag screw is superior and negative if inferior. A receiver operating characteristic curve was used to evaluate the reliability of the different parameters assessing the lag screw position within the femoral head. Results: Reduction quality, fracture pattern as per the AO/OTA classification, TAD, Calcar Referenced TAD, Axis Blade Angle, Parker’s ration in the AP view, Cleveland Zone 1, and modified TAD were statistically associated with lag screw cut-out. Among the tested parameters, the modified TAD had 90.1% sensitivity and 90.9% specificity for lag screw cut-out at a cut-off value of 25 mm with a P-value < 0.001. Conclusion: The modified TAD had the highest reliability in the prediction of lag screw cut-out. A value ≤ 25 mm could potentially protect against lag screw cut-out in trochanteric hip fractures.
first_indexed 2024-03-11T21:44:28Z
format Article
id doaj.art-4693461124b748efbe89689fb5a8d781
institution Directory Open Access Journal
issn 2426-8887
language English
last_indexed 2024-03-11T21:44:28Z
publishDate 2023-01-01
publisher EDP Sciences
record_format Article
series SICOT-J
spelling doaj.art-4693461124b748efbe89689fb5a8d7812023-09-26T10:13:33ZengEDP SciencesSICOT-J2426-88872023-01-0192810.1051/sicotj/2023026sicotj230053Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fracturesSelim Amr0https://orcid.org/0000-0002-0174-6934Al-Hadithy Nawfal1Diab Nader M.2Ahmed Abdulla Mohamed3Kader Khaled Fawzy Abdel4Hegazy Mohamed5https://orcid.org/0000-0002-2575-2001Azeem Hazem Abdel6Barakat Ahmed Samir7https://orcid.org/0000-0002-6778-2364Cairo University HospitalsHillingdon HospitalCairo University HospitalsCairo University HospitalsCairo University HospitalsCairo University HospitalsCairo University HospitalsCairo University HospitalsIntroduction: Lag screw cut-out is a serious complication of dynamic hip screw fixation of trochanteric hip fractures. The lag screw position has been acknowledged as one of the important factors affecting the lag screw cut-out. We propose a modification of the Tip Apex Distance (TAD) and hypothesise that it could improve the reliability of predicting lag screws cut-out in these injuries. Materials and Methods: A retrospective study was conducted for hip fracture entries in the period from Jan 2018 to July 2022. A hundred and nine patients were suitable for the final analysis. The modified TAD was measured in millimetres based on the sum of the traditional TAD in the lateral view and the net value of two distances in the AP view, the first distance is from the tip of the lag screw to the opposite point on the femoral head along the axis of the lag screw while the second distance is from that point to the femoral head apex. The first distance is a positive value, whereas the second distance is positive if the lag screw is superior and negative if inferior. A receiver operating characteristic curve was used to evaluate the reliability of the different parameters assessing the lag screw position within the femoral head. Results: Reduction quality, fracture pattern as per the AO/OTA classification, TAD, Calcar Referenced TAD, Axis Blade Angle, Parker’s ration in the AP view, Cleveland Zone 1, and modified TAD were statistically associated with lag screw cut-out. Among the tested parameters, the modified TAD had 90.1% sensitivity and 90.9% specificity for lag screw cut-out at a cut-off value of 25 mm with a P-value < 0.001. Conclusion: The modified TAD had the highest reliability in the prediction of lag screw cut-out. A value ≤ 25 mm could potentially protect against lag screw cut-out in trochanteric hip fractures.https://www.sicot-j.org/articles/sicotj/full_html/2023/01/sicotj230053/sicotj230053.htmltrochanteric fracturesdhslag screwtip apex distancefixation failurecut-out
spellingShingle Selim Amr
Al-Hadithy Nawfal
Diab Nader M.
Ahmed Abdulla Mohamed
Kader Khaled Fawzy Abdel
Hegazy Mohamed
Azeem Hazem Abdel
Barakat Ahmed Samir
Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fractures
SICOT-J
trochanteric fractures
dhs
lag screw
tip apex distance
fixation failure
cut-out
title Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fractures
title_full Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fractures
title_fullStr Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fractures
title_full_unstemmed Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fractures
title_short Proposal of a modified tip apex distance for prediction of lag screw cut-out in trochanteric hip fractures
title_sort proposal of a modified tip apex distance for prediction of lag screw cut out in trochanteric hip fractures
topic trochanteric fractures
dhs
lag screw
tip apex distance
fixation failure
cut-out
url https://www.sicot-j.org/articles/sicotj/full_html/2023/01/sicotj230053/sicotj230053.html
work_keys_str_mv AT selimamr proposalofamodifiedtipapexdistanceforpredictionoflagscrewcutoutintrochanterichipfractures
AT alhadithynawfal proposalofamodifiedtipapexdistanceforpredictionoflagscrewcutoutintrochanterichipfractures
AT diabnaderm proposalofamodifiedtipapexdistanceforpredictionoflagscrewcutoutintrochanterichipfractures
AT ahmedabdullamohamed proposalofamodifiedtipapexdistanceforpredictionoflagscrewcutoutintrochanterichipfractures
AT kaderkhaledfawzyabdel proposalofamodifiedtipapexdistanceforpredictionoflagscrewcutoutintrochanterichipfractures
AT hegazymohamed proposalofamodifiedtipapexdistanceforpredictionoflagscrewcutoutintrochanterichipfractures
AT azeemhazemabdel proposalofamodifiedtipapexdistanceforpredictionoflagscrewcutoutintrochanterichipfractures
AT barakatahmedsamir proposalofamodifiedtipapexdistanceforpredictionoflagscrewcutoutintrochanterichipfractures