In vitro study of a biological prosthetic valve for seamless fixation
Aim: to evaluate the manipulative properties of the system being developed for cardiac valve re-operation on an in vitro bovine heart model.Material and methods. The prototype of the prosthesis being developed, mounted on the implant holder, as well as the dilatation balloon of its own design, were...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
2018-01-01
|
Series: | Vestnik Transplantologii i Iskusstvennyh Organov |
Subjects: | |
Online Access: | https://journal.transpl.ru/vtio/article/view/829 |
_version_ | 1797871992968314880 |
---|---|
author | K. U. Klyshnikov E. A. Ovcharenko A. N. Stasev N. A. Scheglova Yu. N. Odarenko I. K. Khalivopulo Yu. A. Kudravtseva L. S. Barbarash |
author_facet | K. U. Klyshnikov E. A. Ovcharenko A. N. Stasev N. A. Scheglova Yu. N. Odarenko I. K. Khalivopulo Yu. A. Kudravtseva L. S. Barbarash |
author_sort | K. U. Klyshnikov |
collection | DOAJ |
description | Aim: to evaluate the manipulative properties of the system being developed for cardiac valve re-operation on an in vitro bovine heart model.Material and methods. The prototype of the prosthesis being developed, mounted on the implant holder, as well as the dilatation balloon of its own design, were used as the objects of the study. The bioprosthesis «UniLine» of 21 mm size for the aortic position was chosen as the target site of implantation, which was established by the «classical» suture method. After that, the implantation of the tested device was carried out as a «valve in valve» and the quality of the installation and the combined operation of all the components of the re-prosthesis system were evaluated.Results. The test implantation demonstrated the consistency of the proposed method on the basis of balloon seamless fi xation, as well as high ergonomic characteristics: the average time of seamless implantation of the developed prototype on an in vitro animal heart model was 3 minutes versus the implantation of the «UniLine» bioprosthesis – 11 min, Implantation provided a reliable prosthesis The breaking force was 12.9 N, which is equivalent to a pressure of 279 mm Hg. |
first_indexed | 2024-04-10T00:52:50Z |
format | Article |
id | doaj.art-470c1fab2ccc47c0824459f41a8b84ac |
institution | Directory Open Access Journal |
issn | 1995-1191 |
language | Russian |
last_indexed | 2024-04-10T00:52:50Z |
publishDate | 2018-01-01 |
publisher | Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov |
record_format | Article |
series | Vestnik Transplantologii i Iskusstvennyh Organov |
spelling | doaj.art-470c1fab2ccc47c0824459f41a8b84ac2023-03-13T10:37:24ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.ShumakovVestnik Transplantologii i Iskusstvennyh Organov1995-11912018-01-01194616910.15825/1995-1191-2017-4-61-69662In vitro study of a biological prosthetic valve for seamless fixationK. U. Klyshnikov0E. A. Ovcharenko1A. N. Stasev2N. A. Scheglova3Yu. N. Odarenko4I. K. Khalivopulo5Yu. A. Kudravtseva6L. S. Barbarash7Research Institute for Complex Issues of Cardiovascular Diseases.Research Institute for Complex Issues of Cardiovascular Diseases.Research Institute for Complex Issues of Cardiovascular Diseases.«NeoCor» LLC.Research Institute for Complex Issues of Cardiovascular Diseases.Research Institute for Complex Issues of Cardiovascular Diseases.Research Institute for Complex Issues of Cardiovascular Diseases.Research Institute for Complex Issues of Cardiovascular Diseases.Aim: to evaluate the manipulative properties of the system being developed for cardiac valve re-operation on an in vitro bovine heart model.Material and methods. The prototype of the prosthesis being developed, mounted on the implant holder, as well as the dilatation balloon of its own design, were used as the objects of the study. The bioprosthesis «UniLine» of 21 mm size for the aortic position was chosen as the target site of implantation, which was established by the «classical» suture method. After that, the implantation of the tested device was carried out as a «valve in valve» and the quality of the installation and the combined operation of all the components of the re-prosthesis system were evaluated.Results. The test implantation demonstrated the consistency of the proposed method on the basis of balloon seamless fi xation, as well as high ergonomic characteristics: the average time of seamless implantation of the developed prototype on an in vitro animal heart model was 3 minutes versus the implantation of the «UniLine» bioprosthesis – 11 min, Implantation provided a reliable prosthesis The breaking force was 12.9 N, which is equivalent to a pressure of 279 mm Hg.https://journal.transpl.ru/vtio/article/view/829«valve in valve»aortic valvere-operationballoon system |
spellingShingle | K. U. Klyshnikov E. A. Ovcharenko A. N. Stasev N. A. Scheglova Yu. N. Odarenko I. K. Khalivopulo Yu. A. Kudravtseva L. S. Barbarash In vitro study of a biological prosthetic valve for seamless fixation Vestnik Transplantologii i Iskusstvennyh Organov «valve in valve» aortic valve re-operation balloon system |
title | In vitro study of a biological prosthetic valve for seamless fixation |
title_full | In vitro study of a biological prosthetic valve for seamless fixation |
title_fullStr | In vitro study of a biological prosthetic valve for seamless fixation |
title_full_unstemmed | In vitro study of a biological prosthetic valve for seamless fixation |
title_short | In vitro study of a biological prosthetic valve for seamless fixation |
title_sort | in vitro study of a biological prosthetic valve for seamless fixation |
topic | «valve in valve» aortic valve re-operation balloon system |
url | https://journal.transpl.ru/vtio/article/view/829 |
work_keys_str_mv | AT kuklyshnikov invitrostudyofabiologicalprostheticvalveforseamlessfixation AT eaovcharenko invitrostudyofabiologicalprostheticvalveforseamlessfixation AT anstasev invitrostudyofabiologicalprostheticvalveforseamlessfixation AT nascheglova invitrostudyofabiologicalprostheticvalveforseamlessfixation AT yunodarenko invitrostudyofabiologicalprostheticvalveforseamlessfixation AT ikkhalivopulo invitrostudyofabiologicalprostheticvalveforseamlessfixation AT yuakudravtseva invitrostudyofabiologicalprostheticvalveforseamlessfixation AT lsbarbarash invitrostudyofabiologicalprostheticvalveforseamlessfixation |