Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo The use of pressure generated by a water column to control flow rates in flow analysis systems

<abstract language="eng">This work presents a new approach to control the flow rate in hydrodynamic flow experiments. The combination of air pressure generated by an aquarium air pump and the pressure generated by a water column were used for this purpose. This device supports a stab...

Full description

Bibliographic Details
Main Authors: Wallans T. P. dos Santos, Marselha P. Ceolin, Yaico D. T. de Albuquerque, Eduardo M. Richter
Format: Article
Language:English
Published: Sociedade Brasileira de Química 2007-01-01
Series:Química Nova
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422007000700044
_version_ 1818953438566809600
author Wallans T. P. dos Santos
Marselha P. Ceolin
Yaico D. T. de Albuquerque
Eduardo M. Richter
author_facet Wallans T. P. dos Santos
Marselha P. Ceolin
Yaico D. T. de Albuquerque
Eduardo M. Richter
author_sort Wallans T. P. dos Santos
collection DOAJ
description <abstract language="eng">This work presents a new approach to control the flow rate in hydrodynamic flow experiments. The combination of air pressure generated by an aquarium air pump and the pressure generated by a water column were used for this purpose. This device supports a stable flow rate without pulsation for a long period of time. Furthermore, the flow rate can be easily controlled at various values in one or more streams. The performance of this approach was investigated using Fe(CN)6(4-) solutions in flowing systems using amperometric and voltammetric detection in wall-jet configuration. The results showed that the performance of the proposed device was better than a commercial peristaltic pump. It suggests that this approach can be used successfully in flow analysis systems.
first_indexed 2024-12-20T10:06:17Z
format Article
id doaj.art-4717603351e749e5a7c032a16c745cdd
institution Directory Open Access Journal
issn 0100-4042
1678-7064
language English
last_indexed 2024-12-20T10:06:17Z
publishDate 2007-01-01
publisher Sociedade Brasileira de Química
record_format Article
series Química Nova
spelling doaj.art-4717603351e749e5a7c032a16c745cdd2022-12-21T19:44:13ZengSociedade Brasileira de QuímicaQuímica Nova0100-40421678-70642007-01-013071754175810.1590/S0100-40422007000700044Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo The use of pressure generated by a water column to control flow rates in flow analysis systemsWallans T. P. dos SantosMarselha P. CeolinYaico D. T. de AlbuquerqueEduardo M. Richter<abstract language="eng">This work presents a new approach to control the flow rate in hydrodynamic flow experiments. The combination of air pressure generated by an aquarium air pump and the pressure generated by a water column were used for this purpose. This device supports a stable flow rate without pulsation for a long period of time. Furthermore, the flow rate can be easily controlled at various values in one or more streams. The performance of this approach was investigated using Fe(CN)6(4-) solutions in flowing systems using amperometric and voltammetric detection in wall-jet configuration. The results showed that the performance of the proposed device was better than a commercial peristaltic pump. It suggests that this approach can be used successfully in flow analysis systems.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422007000700044flow rates controlwater columnflow analysis
spellingShingle Wallans T. P. dos Santos
Marselha P. Ceolin
Yaico D. T. de Albuquerque
Eduardo M. Richter
Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo The use of pressure generated by a water column to control flow rates in flow analysis systems
Química Nova
flow rates control
water column
flow analysis
title Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo The use of pressure generated by a water column to control flow rates in flow analysis systems
title_full Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo The use of pressure generated by a water column to control flow rates in flow analysis systems
title_fullStr Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo The use of pressure generated by a water column to control flow rates in flow analysis systems
title_full_unstemmed Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo The use of pressure generated by a water column to control flow rates in flow analysis systems
title_short Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo The use of pressure generated by a water column to control flow rates in flow analysis systems
title_sort uso da pressao gerada por uma coluna de agua para controle da vazao em sistemas de analises em fluxo the use of pressure generated by a water column to control flow rates in flow analysis systems
topic flow rates control
water column
flow analysis
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422007000700044
work_keys_str_mv AT wallanstpdossantos usodapressaogeradaporumacolunadeaguaparacontroledavazaoemsistemasdeanalisesemfluxotheuseofpressuregeneratedbyawatercolumntocontrolflowratesinflowanalysissystems
AT marselhapceolin usodapressaogeradaporumacolunadeaguaparacontroledavazaoemsistemasdeanalisesemfluxotheuseofpressuregeneratedbyawatercolumntocontrolflowratesinflowanalysissystems
AT yaicodtdealbuquerque usodapressaogeradaporumacolunadeaguaparacontroledavazaoemsistemasdeanalisesemfluxotheuseofpressuregeneratedbyawatercolumntocontrolflowratesinflowanalysissystems
AT eduardomrichter usodapressaogeradaporumacolunadeaguaparacontroledavazaoemsistemasdeanalisesemfluxotheuseofpressuregeneratedbyawatercolumntocontrolflowratesinflowanalysissystems