Evaluation of effective doses in CT simulation using CTDIw calculation

Background: Computed Tomography (CT) simulator is used for primary imaging in Department of Radiation Therapy. Although it is also the leading standard of treatment planning since it directly measures electron densities needed for dosage computation, it is known to deliver more radiation dose to p...

Full description

Bibliographic Details
Main Authors: Khemipa Sanklaa, Taweap Sanghangthum, Thanaphat Chongsan
Format: Article
Language:English
Published: Chaing Mai University 2017-09-01
Series:Journal of Associated Medical Sciences
Subjects:
Online Access:https://www.tci-thaijo.org/index.php/bulletinAMS/article/view/79312
_version_ 1819090839624744960
author Khemipa Sanklaa
Taweap Sanghangthum
Thanaphat Chongsan
author_facet Khemipa Sanklaa
Taweap Sanghangthum
Thanaphat Chongsan
author_sort Khemipa Sanklaa
collection DOAJ
description Background: Computed Tomography (CT) simulator is used for primary imaging in Department of Radiation Therapy. Although it is also the leading standard of treatment planning since it directly measures electron densities needed for dosage computation, it is known to deliver more radiation dose to patients. Objectives: The purpose of this study is to determine the effective dose for cancer patients undergoing the CT simulator. Materials and methods: An ionization chamber was used to measure CTDIair in CT simulator (Siemens, Somatom Definition AS, Germany). Measurement of CTDIw was done by placing the Pencil Ionization Chamber (Radcal, USA, SN:05-0340) in PMMA head and body phantoms to measure CTDI100 for the head and abdomen region, respectively. Twenty cases of head, thorax, and pelvic cancer patients were recorded. CTDIvol, DLP, scan length, kV, mAs, pitch, and rotation time parameters were collected in each patient for CTDIw dose calculation to obtain the effective dose. Results: Dose index in air (CTDIair) was 8.84 mGy and CTDIw in PMMA head and body phantom were 16.67 and 10.33 mGy, respectively. Effective doses in head, thorax, and abdomen cases were shown to be 2.20±0.06, 5.01±1.09, 6.90±1.23 mSv, respectively. Conclusion: Effective doses were different in each region. Although, they were less than recommended, it should still be taken into consideration. Protocol optimization in CT simulator should be considered about pitch, scan length, slice thickness and mAs while image quality would be accepted.
first_indexed 2024-12-21T22:30:12Z
format Article
id doaj.art-477517f2f3a74bebb0f389a7985ab5aa
institution Directory Open Access Journal
issn 2539-6056
2539-6056
language English
last_indexed 2024-12-21T22:30:12Z
publishDate 2017-09-01
publisher Chaing Mai University
record_format Article
series Journal of Associated Medical Sciences
spelling doaj.art-477517f2f3a74bebb0f389a7985ab5aa2022-12-21T18:48:06ZengChaing Mai UniversityJournal of Associated Medical Sciences2539-60562539-60562017-09-0150341741779312Evaluation of effective doses in CT simulation using CTDIw calculationKhemipa Sanklaa0Taweap Sanghangthum1Thanaphat Chongsan21 Department of Radiological Technology, Faculty of Allied Health Science, Thammasat University, Pathum Thani Province, Thailand. 2 Department of Radiological Technology, Faculty of Allied Health Science, Chulalongkorn University, Bangkok, Thailand. 3 Department of Radiation Oncology, Thammasat University Hospital, Pathum Thani Province, Thailand.1 Department of Radiological Technology, Faculty of Allied Health Science, Thammasat University, Pathum Thani Province, Thailand. 2 Department of Radiological Technology, Faculty of Allied Health Science, Chulalongkorn University, Bangkok, Thailand. 3 Department of Radiation Oncology, Thammasat University Hospital, Pathum Thani Province, Thailand.1 Department of Radiological Technology, Faculty of Allied Health Science, Thammasat University, Pathum Thani Province, Thailand. 2 Department of Radiological Technology, Faculty of Allied Health Science, Chulalongkorn University, Bangkok, Thailand. 3 Department of Radiation Oncology, Thammasat University Hospital, Pathum Thani Province, Thailand.Background: Computed Tomography (CT) simulator is used for primary imaging in Department of Radiation Therapy. Although it is also the leading standard of treatment planning since it directly measures electron densities needed for dosage computation, it is known to deliver more radiation dose to patients. Objectives: The purpose of this study is to determine the effective dose for cancer patients undergoing the CT simulator. Materials and methods: An ionization chamber was used to measure CTDIair in CT simulator (Siemens, Somatom Definition AS, Germany). Measurement of CTDIw was done by placing the Pencil Ionization Chamber (Radcal, USA, SN:05-0340) in PMMA head and body phantoms to measure CTDI100 for the head and abdomen region, respectively. Twenty cases of head, thorax, and pelvic cancer patients were recorded. CTDIvol, DLP, scan length, kV, mAs, pitch, and rotation time parameters were collected in each patient for CTDIw dose calculation to obtain the effective dose. Results: Dose index in air (CTDIair) was 8.84 mGy and CTDIw in PMMA head and body phantom were 16.67 and 10.33 mGy, respectively. Effective doses in head, thorax, and abdomen cases were shown to be 2.20±0.06, 5.01±1.09, 6.90±1.23 mSv, respectively. Conclusion: Effective doses were different in each region. Although, they were less than recommended, it should still be taken into consideration. Protocol optimization in CT simulator should be considered about pitch, scan length, slice thickness and mAs while image quality would be accepted.https://www.tci-thaijo.org/index.php/bulletinAMS/article/view/79312CT simulatoreffective doseCTDI
spellingShingle Khemipa Sanklaa
Taweap Sanghangthum
Thanaphat Chongsan
Evaluation of effective doses in CT simulation using CTDIw calculation
Journal of Associated Medical Sciences
CT simulator
effective dose
CTDI
title Evaluation of effective doses in CT simulation using CTDIw calculation
title_full Evaluation of effective doses in CT simulation using CTDIw calculation
title_fullStr Evaluation of effective doses in CT simulation using CTDIw calculation
title_full_unstemmed Evaluation of effective doses in CT simulation using CTDIw calculation
title_short Evaluation of effective doses in CT simulation using CTDIw calculation
title_sort evaluation of effective doses in ct simulation using ctdiw calculation
topic CT simulator
effective dose
CTDI
url https://www.tci-thaijo.org/index.php/bulletinAMS/article/view/79312
work_keys_str_mv AT khemipasanklaa evaluationofeffectivedosesinctsimulationusingctdiwcalculation
AT taweapsanghangthum evaluationofeffectivedosesinctsimulationusingctdiwcalculation
AT thanaphatchongsan evaluationofeffectivedosesinctsimulationusingctdiwcalculation