Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test

ABSTRACT Introduction: Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown low complication rates and presents as an option in the treatment of patients at high risk for conventional surgery, avoiding high transvalvular gradients, which are associated with increased mort...

Full description

Bibliographic Details
Main Authors: Andre Lupp Mota, Diego Felipe Gaia, José Honório Palma da Fonseca
Format: Article
Language:English
Published: Sociedade Brasileira de Cirurgia Cardiovascular 2022-06-01
Series:Brazilian Journal of Cardiovascular Surgery
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382022000300301&tlng=en
_version_ 1818543037291167744
author Andre Lupp Mota
Diego Felipe Gaia
José Honório Palma da Fonseca
author_facet Andre Lupp Mota
Diego Felipe Gaia
José Honório Palma da Fonseca
author_sort Andre Lupp Mota
collection DOAJ
description ABSTRACT Introduction: Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown low complication rates and presents as an option in the treatment of patients at high risk for conventional surgery, avoiding high transvalvular gradients, which are associated with increased mortality. Some prostheses available in the market cannot be fractured. In an ex vivo test, the possibility of ring fracture of aortic valve bioprostheses produced in Brazil when submitted to radial force application using a high-pressure non-compliant balloon was evaluated. Methods: One unit of each aortic valve bioprosthesis model, sizes 19 and 21 mm, produced by Brazilian companies (Braile Biomédica, Cardioprótese, and Labcor), was used. In the experiment, a non-compliant high-pressure balloon (Atlas®-Gold), 1 mm larger than the external diameter of the prosthesis, was positioned inside the valve annulus and inflated gradually aiming to fracture the prosthesis. Fracture pressures and photographic and radiological images of the prostheses before and after test were recorded. Results: All prostheses were fractured. In the models with metal ring, the fracture pressures were between 23 and 25 atm. In the other prostheses, the rupture occurred between 10 and 13 atm. No deformations in the structure were observed, which could potentially damage the aortic root. Conclusion: All the Brazilian prostheses evaluated were fractured, although the presence of a metal ring in the prosthesis framework increases the pressure required for fracture. The information obtained helps in the planning of valve-in-valve procedures in patients with aortic valve bioprostheses.
first_indexed 2024-12-11T22:30:02Z
format Article
id doaj.art-47994d9d163a47e4a3094f2654bf8c5a
institution Directory Open Access Journal
issn 1678-9741
language English
last_indexed 2024-12-11T22:30:02Z
publishDate 2022-06-01
publisher Sociedade Brasileira de Cirurgia Cardiovascular
record_format Article
series Brazilian Journal of Cardiovascular Surgery
spelling doaj.art-47994d9d163a47e4a3094f2654bf8c5a2022-12-22T00:48:09ZengSociedade Brasileira de Cirurgia CardiovascularBrazilian Journal of Cardiovascular Surgery1678-97412022-06-0137330130510.21470/1678-9741-2021-0272Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo TestAndre Lupp Motahttps://orcid.org/0000-0002-6624-4492Diego Felipe GaiaJosé Honório Palma da FonsecaABSTRACT Introduction: Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown low complication rates and presents as an option in the treatment of patients at high risk for conventional surgery, avoiding high transvalvular gradients, which are associated with increased mortality. Some prostheses available in the market cannot be fractured. In an ex vivo test, the possibility of ring fracture of aortic valve bioprostheses produced in Brazil when submitted to radial force application using a high-pressure non-compliant balloon was evaluated. Methods: One unit of each aortic valve bioprosthesis model, sizes 19 and 21 mm, produced by Brazilian companies (Braile Biomédica, Cardioprótese, and Labcor), was used. In the experiment, a non-compliant high-pressure balloon (Atlas®-Gold), 1 mm larger than the external diameter of the prosthesis, was positioned inside the valve annulus and inflated gradually aiming to fracture the prosthesis. Fracture pressures and photographic and radiological images of the prostheses before and after test were recorded. Results: All prostheses were fractured. In the models with metal ring, the fracture pressures were between 23 and 25 atm. In the other prostheses, the rupture occurred between 10 and 13 atm. No deformations in the structure were observed, which could potentially damage the aortic root. Conclusion: All the Brazilian prostheses evaluated were fractured, although the presence of a metal ring in the prosthesis framework increases the pressure required for fracture. The information obtained helps in the planning of valve-in-valve procedures in patients with aortic valve bioprostheses.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382022000300301&tlng=enAortic ValveTranscatheter Aortic ValveCardiovascular DiseasesBioprosthesisBalloon Valvuloplasty
spellingShingle Andre Lupp Mota
Diego Felipe Gaia
José Honório Palma da Fonseca
Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test
Brazilian Journal of Cardiovascular Surgery
Aortic Valve
Transcatheter Aortic Valve
Cardiovascular Diseases
Bioprosthesis
Balloon Valvuloplasty
title Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test
title_full Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test
title_fullStr Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test
title_full_unstemmed Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test
title_short Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test
title_sort ring fracture of brazilian aortic valve bioprostheses using non compliant high pressure transcatheter balloon an ex vivo test
topic Aortic Valve
Transcatheter Aortic Valve
Cardiovascular Diseases
Bioprosthesis
Balloon Valvuloplasty
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382022000300301&tlng=en
work_keys_str_mv AT andreluppmota ringfractureofbrazilianaorticvalvebioprosthesesusingnoncomplianthighpressuretranscatheterballoonanexvivotest
AT diegofelipegaia ringfractureofbrazilianaorticvalvebioprosthesesusingnoncomplianthighpressuretranscatheterballoonanexvivotest
AT josehonoriopalmadafonseca ringfractureofbrazilianaorticvalvebioprosthesesusingnoncomplianthighpressuretranscatheterballoonanexvivotest