Analysis of equivalent circuit of test of intrinsic safety circuit

Taking an intrinsic safety circuit of passive rescue telephone as an example, the paper analyzed test process of safe spark test of the circuit under different electrical principle equivalent diagrams of intrinsic safety test, and indicated that spark apparatus should be connected into test points w...

Full description

Bibliographic Details
Main Author: LIU Qi
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2013-10-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.7526/j.issn.1671-251X.2013.10.029
_version_ 1797868626601050112
author LIU Qi
author_facet LIU Qi
author_sort LIU Qi
collection DOAJ
description Taking an intrinsic safety circuit of passive rescue telephone as an example, the paper analyzed test process of safe spark test of the circuit under different electrical principle equivalent diagrams of intrinsic safety test, and indicated that spark apparatus should be connected into test points which maybe produce the highest spark energy in the tested circuit, which can ensure intrinsic safety circuit has enough safety factor after passing spark test.
first_indexed 2024-04-09T23:58:53Z
format Article
id doaj.art-48eb4e2a1b3a4330b99ed9cb79a26035
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-09T23:58:53Z
publishDate 2013-10-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-48eb4e2a1b3a4330b99ed9cb79a260352023-03-17T01:53:00ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2013-10-01391011411610.7526/j.issn.1671-251X.2013.10.029Analysis of equivalent circuit of test of intrinsic safety circuitLIU QiTaking an intrinsic safety circuit of passive rescue telephone as an example, the paper analyzed test process of safe spark test of the circuit under different electrical principle equivalent diagrams of intrinsic safety test, and indicated that spark apparatus should be connected into test points which maybe produce the highest spark energy in the tested circuit, which can ensure intrinsic safety circuit has enough safety factor after passing spark test.http://www.gkzdh.cn/article/doi/10.7526/j.issn.1671-251X.2013.10.029intrinsic safety circuitib levelpassive rescue telephoneequivalent diagram of electrical principlemaximum open-circuit voltagemaximum short-circuit current
spellingShingle LIU Qi
Analysis of equivalent circuit of test of intrinsic safety circuit
Gong-kuang zidonghua
intrinsic safety circuit
ib level
passive rescue telephone
equivalent diagram of electrical principle
maximum open-circuit voltage
maximum short-circuit current
title Analysis of equivalent circuit of test of intrinsic safety circuit
title_full Analysis of equivalent circuit of test of intrinsic safety circuit
title_fullStr Analysis of equivalent circuit of test of intrinsic safety circuit
title_full_unstemmed Analysis of equivalent circuit of test of intrinsic safety circuit
title_short Analysis of equivalent circuit of test of intrinsic safety circuit
title_sort analysis of equivalent circuit of test of intrinsic safety circuit
topic intrinsic safety circuit
ib level
passive rescue telephone
equivalent diagram of electrical principle
maximum open-circuit voltage
maximum short-circuit current
url http://www.gkzdh.cn/article/doi/10.7526/j.issn.1671-251X.2013.10.029
work_keys_str_mv AT liuqi analysisofequivalentcircuitoftestofintrinsicsafetycircuit