Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest
Background: Reusable suction-cup electrodes are used for recording a 12-lead electrocardiogram (ECG) in resource-limited settings. These electrodes may easily detach if those are attached on a hirsute chest. Additionally, the suction pressure may cause erythema and pain. Aim: The aim of this study w...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2020-01-01
|
Series: | Journal of Family Medicine and Primary Care |
Subjects: | |
Online Access: | http://www.jfmpc.com/article.asp?issn=2249-4863;year=2020;volume=9;issue=5;spage=2359;epage=2363;aulast=Mondal |
_version_ | 1818259763805290496 |
---|---|
author | Himel Mondal Tanmoy Chattopadhyay Shaikat Mondal Debasish Das Sairavi Kiran Biri |
author_facet | Himel Mondal Tanmoy Chattopadhyay Shaikat Mondal Debasish Das Sairavi Kiran Biri |
author_sort | Himel Mondal |
collection | DOAJ |
description | Background: Reusable suction-cup electrodes are used for recording a 12-lead electrocardiogram (ECG) in resource-limited settings. These electrodes may easily detach if those are attached on a hirsute chest. Additionally, the suction pressure may cause erythema and pain. Aim: The aim of this study was to develop a low-cost strap for holding the suction-cup-based precordial electrodes and to test its applicability to the recording of ECG. Materials and Methods: A scrap rubber tube was cut in size so that it can cover all the precordial electrode positions. Slit openings (electrodes can be inserted through these opening) were made on this rubber strap. A cloth and a hook-and-loop fastener were used to make an adjustable fastener. ECG was recorded first on 16 non-hairy males with electrodes placed on the chest with the strap and then with electrodes attached by suction. After that, ECG was recorded on 16 males with hirsute chest first with the electrodes placed with the help of the strap and then with suction (without strap) on the shaved chest. Results: The outcome of this study is a low-cost ECG chest strap for a hirsute chest. Both the negative and positive QRS voltages in six precordial leads recorded with electrodes placed with the strap were similar to that of suction-attached electrodes in both non-hairy and hirsute chest. Conclusion: Developed rubber chest strap can be made with minimal cost and expertise in any resource-limited settings. This would help in recording the ECG of a patient with a hirsute chest. This prototype strap has scope for further improvement. |
first_indexed | 2024-12-12T18:20:37Z |
format | Article |
id | doaj.art-48f1f7f603ed4c7089697ec43a6a6527 |
institution | Directory Open Access Journal |
issn | 2249-4863 |
language | English |
last_indexed | 2024-12-12T18:20:37Z |
publishDate | 2020-01-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Journal of Family Medicine and Primary Care |
spelling | doaj.art-48f1f7f603ed4c7089697ec43a6a65272022-12-22T00:16:09ZengWolters Kluwer Medknow PublicationsJournal of Family Medicine and Primary Care2249-48632020-01-01952359236310.4103/jfmpc.jfmpc_292_20Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chestHimel MondalTanmoy ChattopadhyayShaikat MondalDebasish DasSairavi Kiran BiriBackground: Reusable suction-cup electrodes are used for recording a 12-lead electrocardiogram (ECG) in resource-limited settings. These electrodes may easily detach if those are attached on a hirsute chest. Additionally, the suction pressure may cause erythema and pain. Aim: The aim of this study was to develop a low-cost strap for holding the suction-cup-based precordial electrodes and to test its applicability to the recording of ECG. Materials and Methods: A scrap rubber tube was cut in size so that it can cover all the precordial electrode positions. Slit openings (electrodes can be inserted through these opening) were made on this rubber strap. A cloth and a hook-and-loop fastener were used to make an adjustable fastener. ECG was recorded first on 16 non-hairy males with electrodes placed on the chest with the strap and then with electrodes attached by suction. After that, ECG was recorded on 16 males with hirsute chest first with the electrodes placed with the help of the strap and then with suction (without strap) on the shaved chest. Results: The outcome of this study is a low-cost ECG chest strap for a hirsute chest. Both the negative and positive QRS voltages in six precordial leads recorded with electrodes placed with the strap were similar to that of suction-attached electrodes in both non-hairy and hirsute chest. Conclusion: Developed rubber chest strap can be made with minimal cost and expertise in any resource-limited settings. This would help in recording the ECG of a patient with a hirsute chest. This prototype strap has scope for further improvement.http://www.jfmpc.com/article.asp?issn=2249-4863;year=2020;volume=9;issue=5;spage=2359;epage=2363;aulast=Mondalchest leadecg strapekgelectrocardiographyelectrodeserythemainnovation |
spellingShingle | Himel Mondal Tanmoy Chattopadhyay Shaikat Mondal Debasish Das Sairavi Kiran Biri Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest Journal of Family Medicine and Primary Care chest lead ecg strap ekg electrocardiography electrodes erythema innovation |
title | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_full | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_fullStr | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_full_unstemmed | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_short | Fabrication of a low-cost strap for holding precordial electrodes on the hirsute chest |
title_sort | fabrication of a low cost strap for holding precordial electrodes on the hirsute chest |
topic | chest lead ecg strap ekg electrocardiography electrodes erythema innovation |
url | http://www.jfmpc.com/article.asp?issn=2249-4863;year=2020;volume=9;issue=5;spage=2359;epage=2363;aulast=Mondal |
work_keys_str_mv | AT himelmondal fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest AT tanmoychattopadhyay fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest AT shaikatmondal fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest AT debasishdas fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest AT sairavikiranbiri fabricationofalowcoststrapforholdingprecordialelectrodesonthehirsutechest |