A Theoretical and Experimental Study of a Piezoelectric Pump with Two Elastic Chambers

The paper is a continuation of our work on the dynamic load in piezoelectric pumps. In the study, the dynamic load of liquid in the pipelines was proposed as a key factor that limits the output performance of piezoelectric pumps. To decrease the dynamic load, a piezoelectric pump with two elastic ch...

Full description

Bibliographic Details
Main Authors: Xiaolong Zhao, Dingxuan Zhao, Qinghe Guo
Format: Article
Language:English
Published: MDPI AG 2020-10-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/20/20/5867
_version_ 1797550722380726272
author Xiaolong Zhao
Dingxuan Zhao
Qinghe Guo
author_facet Xiaolong Zhao
Dingxuan Zhao
Qinghe Guo
author_sort Xiaolong Zhao
collection DOAJ
description The paper is a continuation of our work on the dynamic load in piezoelectric pumps. In the study, the dynamic load of liquid in the pipelines was proposed as a key factor that limits the output performance of piezoelectric pumps. To decrease the dynamic load, a piezoelectric pump with two elastic chambers was proposed in our previous published work. In this paper, the performance and key parameters of the piezoelectric pump with two elastic chambers were studied through theoretical analyses and experimental tests. After establishing the mathematical model of the piezoelectric pump with two elastic chambers, the paper theoretically analyzed the performance of the pump and the effect of different structural parameters on the performance. Then prototypes with a range of structural parameters were developed and tested. As revealed from the test results, the elastic chamber effectively decreased the dynamic load of the liquid in the pipelines and the flow rate of the prototype with two elastic chambers was higher than that of the prototype with one or no elastic chamber. However, the elastic chamber did not lead to the increase in the maximum output backpressure of the prototype. Adopting an elastic diaphragm exhibiting a smaller stiffness or a larger diameter could help decrease the dynamic load of the liquid. The elastic chamber more significantly impacted the flow rate of the piezoelectric pump with long pipelines. The pump chamber height had a significant effect on the output performance of the piezoelectric pump with two elastic chambers, which is consistent with the conventional piezoelectric pump. At the height of 0.2 mm, the flow rate of the prototype with two elastic chambers was peaked at 7.7 mL/min; at the height of 0.05 mm, the output backpressure reached the highest of 28.2 kPa. The dynamic load could decrease the amplitude of the piezoelectric vibrator, whereas the prototype with two elastic chambers could effectively reduce the impact of dynamic load on the piezoelectric vibrator. The flow rate decreased almost linearly with the backpressure. Under the same backpressure, the flow rate of the prototype with two elastic chambers was higher than that of the prototype without elastic chamber, and the flow rate difference between the two prototypes gradually decreased with the backpressure.
first_indexed 2024-03-10T15:33:21Z
format Article
id doaj.art-48fb947823a54c44b74e1c19bd77cd9f
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-10T15:33:21Z
publishDate 2020-10-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-48fb947823a54c44b74e1c19bd77cd9f2023-11-20T17:26:04ZengMDPI AGSensors1424-82202020-10-012020586710.3390/s20205867A Theoretical and Experimental Study of a Piezoelectric Pump with Two Elastic ChambersXiaolong Zhao0Dingxuan Zhao1Qinghe Guo2School of Mechanical Engineering, Yanshan University, Qinhuangdao 066004, ChinaSchool of Mechanical Engineering, Yanshan University, Qinhuangdao 066004, ChinaSchool of Mechanical Engineering, Yanshan University, Qinhuangdao 066004, ChinaThe paper is a continuation of our work on the dynamic load in piezoelectric pumps. In the study, the dynamic load of liquid in the pipelines was proposed as a key factor that limits the output performance of piezoelectric pumps. To decrease the dynamic load, a piezoelectric pump with two elastic chambers was proposed in our previous published work. In this paper, the performance and key parameters of the piezoelectric pump with two elastic chambers were studied through theoretical analyses and experimental tests. After establishing the mathematical model of the piezoelectric pump with two elastic chambers, the paper theoretically analyzed the performance of the pump and the effect of different structural parameters on the performance. Then prototypes with a range of structural parameters were developed and tested. As revealed from the test results, the elastic chamber effectively decreased the dynamic load of the liquid in the pipelines and the flow rate of the prototype with two elastic chambers was higher than that of the prototype with one or no elastic chamber. However, the elastic chamber did not lead to the increase in the maximum output backpressure of the prototype. Adopting an elastic diaphragm exhibiting a smaller stiffness or a larger diameter could help decrease the dynamic load of the liquid. The elastic chamber more significantly impacted the flow rate of the piezoelectric pump with long pipelines. The pump chamber height had a significant effect on the output performance of the piezoelectric pump with two elastic chambers, which is consistent with the conventional piezoelectric pump. At the height of 0.2 mm, the flow rate of the prototype with two elastic chambers was peaked at 7.7 mL/min; at the height of 0.05 mm, the output backpressure reached the highest of 28.2 kPa. The dynamic load could decrease the amplitude of the piezoelectric vibrator, whereas the prototype with two elastic chambers could effectively reduce the impact of dynamic load on the piezoelectric vibrator. The flow rate decreased almost linearly with the backpressure. Under the same backpressure, the flow rate of the prototype with two elastic chambers was higher than that of the prototype without elastic chamber, and the flow rate difference between the two prototypes gradually decreased with the backpressure.https://www.mdpi.com/1424-8220/20/20/5867piezoelectric pumpelastic chamberdynamic loadelastic diaphragm
spellingShingle Xiaolong Zhao
Dingxuan Zhao
Qinghe Guo
A Theoretical and Experimental Study of a Piezoelectric Pump with Two Elastic Chambers
Sensors
piezoelectric pump
elastic chamber
dynamic load
elastic diaphragm
title A Theoretical and Experimental Study of a Piezoelectric Pump with Two Elastic Chambers
title_full A Theoretical and Experimental Study of a Piezoelectric Pump with Two Elastic Chambers
title_fullStr A Theoretical and Experimental Study of a Piezoelectric Pump with Two Elastic Chambers
title_full_unstemmed A Theoretical and Experimental Study of a Piezoelectric Pump with Two Elastic Chambers
title_short A Theoretical and Experimental Study of a Piezoelectric Pump with Two Elastic Chambers
title_sort theoretical and experimental study of a piezoelectric pump with two elastic chambers
topic piezoelectric pump
elastic chamber
dynamic load
elastic diaphragm
url https://www.mdpi.com/1424-8220/20/20/5867
work_keys_str_mv AT xiaolongzhao atheoreticalandexperimentalstudyofapiezoelectricpumpwithtwoelasticchambers
AT dingxuanzhao atheoreticalandexperimentalstudyofapiezoelectricpumpwithtwoelasticchambers
AT qingheguo atheoreticalandexperimentalstudyofapiezoelectricpumpwithtwoelasticchambers
AT xiaolongzhao theoreticalandexperimentalstudyofapiezoelectricpumpwithtwoelasticchambers
AT dingxuanzhao theoreticalandexperimentalstudyofapiezoelectricpumpwithtwoelasticchambers
AT qingheguo theoreticalandexperimentalstudyofapiezoelectricpumpwithtwoelasticchambers