Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System

Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional st...

Full description

Bibliographic Details
Main Authors: José Ignacio Fernández-Vigo, Bárbara Burgos-Blasco, Lucía De-Pablo-Gómez-de-Liaño, Inés Sánchez-Guillén, Virginia Albitre-Barca, Susana Fernández-Aragón, José Ángel Fernández-Vigo, Ana Macarro-Merino
Format: Article
Language:English
Published: MDPI AG 2023-03-01
Series:Journal of Clinical Medicine
Subjects:
Online Access:https://www.mdpi.com/2077-0383/12/6/2351
_version_ 1797610943290540032
author José Ignacio Fernández-Vigo
Bárbara Burgos-Blasco
Lucía De-Pablo-Gómez-de-Liaño
Inés Sánchez-Guillén
Virginia Albitre-Barca
Susana Fernández-Aragón
José Ángel Fernández-Vigo
Ana Macarro-Merino
author_facet José Ignacio Fernández-Vigo
Bárbara Burgos-Blasco
Lucía De-Pablo-Gómez-de-Liaño
Inés Sánchez-Guillén
Virginia Albitre-Barca
Susana Fernández-Aragón
José Ángel Fernández-Vigo
Ana Macarro-Merino
author_sort José Ignacio Fernández-Vigo
collection DOAJ
description Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional study on a sample of 150 eyes of 150 patients who underwent cataract surgery in at least 600 days before the exam and attended a routine examination. Each subject was examined by SS-OCT after pupil dilation, identifying the presence of glistening or hyperreflective foci (HRF) in the central area of the IOL. The degree of glistening was classified into four categories: 0: ≤5 HRF; 1: 6 to 15 HRF; 2: 16 to 30 HRF; and 3: >30 HRF. The intra and interobserver reproducibility (intraclass correlation coefficient, ICC) in the quantification and classification of the glistening were calculated. The correlation between the horizontal and vertical scan of the IOL was also assessed. Results: Glistening was present in the IOL in 42.7% of the patients. The mean number of HRF or glistening microvacuoles was 10.4 ± 26.2 (range 0 to 239). In total, 63.3% of the IOLs had a grade 0, 20% grade a 1, 6.7% grade a 2 and 10% a grade 3. The intraobserver and interobserver reproducibility were very high, both for the absolute quantification of the glistening (ICC ≥ 0.994) and for the severity scale (ICC ≥ 0.967). There was an excellent correlation in the quantification of the IOL glistening between the horizontal and vertical scans (R ≥ 0.834; <i>p</i> < 0.001). Conclusions: The use of SS-OCT makes it possible to identify, quantify and classify IOL glistening in a simple, objective and reproducible way. This technique could provide relevant information for the study of the glistening on IOLs.
first_indexed 2024-03-11T06:21:58Z
format Article
id doaj.art-48ff0300bb334846ba5cf9bfbf824922
institution Directory Open Access Journal
issn 2077-0383
language English
last_indexed 2024-03-11T06:21:58Z
publishDate 2023-03-01
publisher MDPI AG
record_format Article
series Journal of Clinical Medicine
spelling doaj.art-48ff0300bb334846ba5cf9bfbf8249222023-11-17T11:51:40ZengMDPI AGJournal of Clinical Medicine2077-03832023-03-01126235110.3390/jcm12062351Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading SystemJosé Ignacio Fernández-Vigo0Bárbara Burgos-Blasco1Lucía De-Pablo-Gómez-de-Liaño2Inés Sánchez-Guillén3Virginia Albitre-Barca4Susana Fernández-Aragón5José Ángel Fernández-Vigo6Ana Macarro-Merino7Centro Internacional de Oftalmología Avanzada, 28010 Madrid, SpainDepartment of Ophthalmology, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), 28040 Madrid, SpainCentro Internacional de Oftalmología Avanzada, 28010 Madrid, SpainDepartment of Ophthalmology, Hospital Perpetuo Socorro, 06010 Badajoz, SpainCentro Internacional de Oftalmología Avanzada, 28010 Madrid, SpainCentro Internacional de Oftalmología Avanzada, 28010 Madrid, SpainCentro Internacional de Oftalmología Avanzada, 28010 Madrid, SpainCentro Internacional de Oftalmología Avanzada, 28010 Madrid, SpainPurpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional study on a sample of 150 eyes of 150 patients who underwent cataract surgery in at least 600 days before the exam and attended a routine examination. Each subject was examined by SS-OCT after pupil dilation, identifying the presence of glistening or hyperreflective foci (HRF) in the central area of the IOL. The degree of glistening was classified into four categories: 0: ≤5 HRF; 1: 6 to 15 HRF; 2: 16 to 30 HRF; and 3: >30 HRF. The intra and interobserver reproducibility (intraclass correlation coefficient, ICC) in the quantification and classification of the glistening were calculated. The correlation between the horizontal and vertical scan of the IOL was also assessed. Results: Glistening was present in the IOL in 42.7% of the patients. The mean number of HRF or glistening microvacuoles was 10.4 ± 26.2 (range 0 to 239). In total, 63.3% of the IOLs had a grade 0, 20% grade a 1, 6.7% grade a 2 and 10% a grade 3. The intraobserver and interobserver reproducibility were very high, both for the absolute quantification of the glistening (ICC ≥ 0.994) and for the severity scale (ICC ≥ 0.967). There was an excellent correlation in the quantification of the IOL glistening between the horizontal and vertical scans (R ≥ 0.834; <i>p</i> < 0.001). Conclusions: The use of SS-OCT makes it possible to identify, quantify and classify IOL glistening in a simple, objective and reproducible way. This technique could provide relevant information for the study of the glistening on IOLs.https://www.mdpi.com/2077-0383/12/6/2351glisteningintraocular lensopacificationoptical coherence tomography
spellingShingle José Ignacio Fernández-Vigo
Bárbara Burgos-Blasco
Lucía De-Pablo-Gómez-de-Liaño
Inés Sánchez-Guillén
Virginia Albitre-Barca
Susana Fernández-Aragón
José Ángel Fernández-Vigo
Ana Macarro-Merino
Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System
Journal of Clinical Medicine
glistening
intraocular lens
opacification
optical coherence tomography
title Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System
title_full Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System
title_fullStr Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System
title_full_unstemmed Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System
title_short Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System
title_sort objective classification of glistening in implanted intraocular lenses using optical coherence tomography proposal for a new classification and grading system
topic glistening
intraocular lens
opacification
optical coherence tomography
url https://www.mdpi.com/2077-0383/12/6/2351
work_keys_str_mv AT joseignaciofernandezvigo objectiveclassificationofglisteninginimplantedintraocularlensesusingopticalcoherencetomographyproposalforanewclassificationandgradingsystem
AT barbaraburgosblasco objectiveclassificationofglisteninginimplantedintraocularlensesusingopticalcoherencetomographyproposalforanewclassificationandgradingsystem
AT luciadepablogomezdeliano objectiveclassificationofglisteninginimplantedintraocularlensesusingopticalcoherencetomographyproposalforanewclassificationandgradingsystem
AT inessanchezguillen objectiveclassificationofglisteninginimplantedintraocularlensesusingopticalcoherencetomographyproposalforanewclassificationandgradingsystem
AT virginiaalbitrebarca objectiveclassificationofglisteninginimplantedintraocularlensesusingopticalcoherencetomographyproposalforanewclassificationandgradingsystem
AT susanafernandezaragon objectiveclassificationofglisteninginimplantedintraocularlensesusingopticalcoherencetomographyproposalforanewclassificationandgradingsystem
AT joseangelfernandezvigo objectiveclassificationofglisteninginimplantedintraocularlensesusingopticalcoherencetomographyproposalforanewclassificationandgradingsystem
AT anamacarromerino objectiveclassificationofglisteninginimplantedintraocularlensesusingopticalcoherencetomographyproposalforanewclassificationandgradingsystem