Hot water lower limit temperature characteristics of hot water fired absorption chiller using multi-stage absorption
The design limits of a hot water fired absorption chiller in a cycle simulation were examined. The authors have already proposed how to determine the lowest limiting value of the smaller of the two temperature differences to get a logarithmic mean temperature difference when designing each element....
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | Japanese |
Published: |
The Japan Society of Mechanical Engineers
2014-06-01
|
Series: | Nihon Kikai Gakkai ronbunshu |
Subjects: | |
Online Access: | https://www.jstage.jst.go.jp/article/transjsme/80/814/80_2014tep0152/_pdf/-char/en |
_version_ | 1811224920130060288 |
---|---|
author | Shuji ESAKI Takahiro KOBAYASHI Masayuki OHNOU Toshiyuki KANEKO |
author_facet | Shuji ESAKI Takahiro KOBAYASHI Masayuki OHNOU Toshiyuki KANEKO |
author_sort | Shuji ESAKI |
collection | DOAJ |
description | The design limits of a hot water fired absorption chiller in a cycle simulation were examined. The authors have already proposed how to determine the lowest limiting value of the smaller of the two temperature differences to get a logarithmic mean temperature difference when designing each element. This new algorithm was applied, based on the trend toward the hot water fired absorption chiller that employs a multi-stage absorption system. After performing a cycle simulation, the effects of stage number for the lowest hot water temperature that could be used in air conditioning were clarified. As a result, it was found that the limits of stage number were existed. It was also found that the lowest limiting temperature of hot water could be theoretically determined in the condition of the infinite-stage absorption system. |
first_indexed | 2024-04-12T08:56:57Z |
format | Article |
id | doaj.art-4947930d2a7f42b99ac15635cf921687 |
institution | Directory Open Access Journal |
issn | 2187-9761 |
language | Japanese |
last_indexed | 2024-04-12T08:56:57Z |
publishDate | 2014-06-01 |
publisher | The Japan Society of Mechanical Engineers |
record_format | Article |
series | Nihon Kikai Gakkai ronbunshu |
spelling | doaj.art-4947930d2a7f42b99ac15635cf9216872022-12-22T03:39:21ZjpnThe Japan Society of Mechanical EngineersNihon Kikai Gakkai ronbunshu2187-97612014-06-0180814TEP0152TEP015210.1299/transjsme.2014tep0152transjsmeHot water lower limit temperature characteristics of hot water fired absorption chiller using multi-stage absorptionShuji ESAKI0Takahiro KOBAYASHI1Masayuki OHNOU2Toshiyuki KANEKO3Kagoshima National College of Technology, Dept. of Mechanical EngineeringPanasonic Corporation Appliances CompanySOGA Iron WorksSOGA Iron WorksThe design limits of a hot water fired absorption chiller in a cycle simulation were examined. The authors have already proposed how to determine the lowest limiting value of the smaller of the two temperature differences to get a logarithmic mean temperature difference when designing each element. This new algorithm was applied, based on the trend toward the hot water fired absorption chiller that employs a multi-stage absorption system. After performing a cycle simulation, the effects of stage number for the lowest hot water temperature that could be used in air conditioning were clarified. As a result, it was found that the limits of stage number were existed. It was also found that the lowest limiting temperature of hot water could be theoretically determined in the condition of the infinite-stage absorption system.https://www.jstage.jst.go.jp/article/transjsme/80/814/80_2014tep0152/_pdf/-char/enabsorption refrigerating machinerefrigeration cyclesimulationheat exchangerabsorberevaporatorcondensergenerator |
spellingShingle | Shuji ESAKI Takahiro KOBAYASHI Masayuki OHNOU Toshiyuki KANEKO Hot water lower limit temperature characteristics of hot water fired absorption chiller using multi-stage absorption Nihon Kikai Gakkai ronbunshu absorption refrigerating machine refrigeration cycle simulation heat exchanger absorber evaporator condenser generator |
title | Hot water lower limit temperature characteristics of hot water fired absorption chiller using multi-stage absorption |
title_full | Hot water lower limit temperature characteristics of hot water fired absorption chiller using multi-stage absorption |
title_fullStr | Hot water lower limit temperature characteristics of hot water fired absorption chiller using multi-stage absorption |
title_full_unstemmed | Hot water lower limit temperature characteristics of hot water fired absorption chiller using multi-stage absorption |
title_short | Hot water lower limit temperature characteristics of hot water fired absorption chiller using multi-stage absorption |
title_sort | hot water lower limit temperature characteristics of hot water fired absorption chiller using multi stage absorption |
topic | absorption refrigerating machine refrigeration cycle simulation heat exchanger absorber evaporator condenser generator |
url | https://www.jstage.jst.go.jp/article/transjsme/80/814/80_2014tep0152/_pdf/-char/en |
work_keys_str_mv | AT shujiesaki hotwaterlowerlimittemperaturecharacteristicsofhotwaterfiredabsorptionchillerusingmultistageabsorption AT takahirokobayashi hotwaterlowerlimittemperaturecharacteristicsofhotwaterfiredabsorptionchillerusingmultistageabsorption AT masayukiohnou hotwaterlowerlimittemperaturecharacteristicsofhotwaterfiredabsorptionchillerusingmultistageabsorption AT toshiyukikaneko hotwaterlowerlimittemperaturecharacteristicsofhotwaterfiredabsorptionchillerusingmultistageabsorption |