A constrained engineering design method for constant-current remote power supply system of mesh-type cabled underwater information networks

Remote power supply technology is critical for the long-term, wide-area, and real-time monitoring of marine data in cabled underwater information networks (CUINs). In this study, the constant-current remote power supply system (CCRPSS) of mesh-type CUINs based on constant-current branch equipment (C...

Full description

Bibliographic Details
Main Authors: Xichen Wang, Xiaorui Qiao, Xuejun Zhou
Format: Article
Language:English
Published: Elsevier 2023-12-01
Series:Energy Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2352484723001099
_version_ 1797781921081589760
author Xichen Wang
Xiaorui Qiao
Xuejun Zhou
author_facet Xichen Wang
Xiaorui Qiao
Xuejun Zhou
author_sort Xichen Wang
collection DOAJ
description Remote power supply technology is critical for the long-term, wide-area, and real-time monitoring of marine data in cabled underwater information networks (CUINs). In this study, the constant-current remote power supply system (CCRPSS) of mesh-type CUINs based on constant-current branch equipment (CCBE) and constant-current/constant-voltage conversion equipment (CCVE) is studied. The system can be categorized into various power supply links and link segments according to the current flow path and structural characteristics. A system basic simulation model is designed to analyze the influence of 11 typical faults on the working state of the system and to summarize the influence of the open-circuit/short-circuit faults of various underwater units in different power supply link segments on the working state of the system. Then the analysis method of power supply reliability (PSR) of the observation equipment (OE) is proposed. The PSR of the OE of the same power supply link (PSL) decreases gradually from shore to sea, and the PSR of the OE located at the center of the PSL is the lowest in the regular deployment of the CCRPSS. To increase the number of nodes deployed and to reduce the total cost, an engineering design method for the system that integrates the constraints of the PSR of the OE, the fault rate of the underwater unit, and the number of second nodes of each power supply link segment (PSLS) is proposed based on invasive weed optimization (IWO). Through the example simulation, the results of the system cost, the deployment number of secondary nodes, and the reliability of the underwater units are obtained, which also confirms that the PSR of the OE located at the center of the PSL is the lowest. This method can be effectively applied to the engineering design of CCRPSS and can provide theoretical and technical support for future large-scale CUINs construction.
first_indexed 2024-03-13T00:03:46Z
format Article
id doaj.art-4983c99df762457ca9eb8cc0cd06e3d9
institution Directory Open Access Journal
issn 2352-4847
language English
last_indexed 2024-03-13T00:03:46Z
publishDate 2023-12-01
publisher Elsevier
record_format Article
series Energy Reports
spelling doaj.art-4983c99df762457ca9eb8cc0cd06e3d92023-07-13T05:29:21ZengElsevierEnergy Reports2352-48472023-12-01925252537A constrained engineering design method for constant-current remote power supply system of mesh-type cabled underwater information networksXichen Wang0Xiaorui Qiao1Xuejun Zhou2Electronic Engineering College, Naval University of Engineering, Wuhan, ChinaCorresponding author.; Electronic Engineering College, Naval University of Engineering, Wuhan, ChinaElectronic Engineering College, Naval University of Engineering, Wuhan, ChinaRemote power supply technology is critical for the long-term, wide-area, and real-time monitoring of marine data in cabled underwater information networks (CUINs). In this study, the constant-current remote power supply system (CCRPSS) of mesh-type CUINs based on constant-current branch equipment (CCBE) and constant-current/constant-voltage conversion equipment (CCVE) is studied. The system can be categorized into various power supply links and link segments according to the current flow path and structural characteristics. A system basic simulation model is designed to analyze the influence of 11 typical faults on the working state of the system and to summarize the influence of the open-circuit/short-circuit faults of various underwater units in different power supply link segments on the working state of the system. Then the analysis method of power supply reliability (PSR) of the observation equipment (OE) is proposed. The PSR of the OE of the same power supply link (PSL) decreases gradually from shore to sea, and the PSR of the OE located at the center of the PSL is the lowest in the regular deployment of the CCRPSS. To increase the number of nodes deployed and to reduce the total cost, an engineering design method for the system that integrates the constraints of the PSR of the OE, the fault rate of the underwater unit, and the number of second nodes of each power supply link segment (PSLS) is proposed based on invasive weed optimization (IWO). Through the example simulation, the results of the system cost, the deployment number of secondary nodes, and the reliability of the underwater units are obtained, which also confirms that the PSR of the OE located at the center of the PSL is the lowest. This method can be effectively applied to the engineering design of CCRPSS and can provide theoretical and technical support for future large-scale CUINs construction.http://www.sciencedirect.com/science/article/pii/S2352484723001099Cabled underwater information networks (CUINs)Constant-current remote power supply system (CCRPSS)Mesh-typeOpen-circuit/short-circuit faultReliabilityConstraint engineering design
spellingShingle Xichen Wang
Xiaorui Qiao
Xuejun Zhou
A constrained engineering design method for constant-current remote power supply system of mesh-type cabled underwater information networks
Energy Reports
Cabled underwater information networks (CUINs)
Constant-current remote power supply system (CCRPSS)
Mesh-type
Open-circuit/short-circuit fault
Reliability
Constraint engineering design
title A constrained engineering design method for constant-current remote power supply system of mesh-type cabled underwater information networks
title_full A constrained engineering design method for constant-current remote power supply system of mesh-type cabled underwater information networks
title_fullStr A constrained engineering design method for constant-current remote power supply system of mesh-type cabled underwater information networks
title_full_unstemmed A constrained engineering design method for constant-current remote power supply system of mesh-type cabled underwater information networks
title_short A constrained engineering design method for constant-current remote power supply system of mesh-type cabled underwater information networks
title_sort constrained engineering design method for constant current remote power supply system of mesh type cabled underwater information networks
topic Cabled underwater information networks (CUINs)
Constant-current remote power supply system (CCRPSS)
Mesh-type
Open-circuit/short-circuit fault
Reliability
Constraint engineering design
url http://www.sciencedirect.com/science/article/pii/S2352484723001099
work_keys_str_mv AT xichenwang aconstrainedengineeringdesignmethodforconstantcurrentremotepowersupplysystemofmeshtypecabledunderwaterinformationnetworks
AT xiaoruiqiao aconstrainedengineeringdesignmethodforconstantcurrentremotepowersupplysystemofmeshtypecabledunderwaterinformationnetworks
AT xuejunzhou aconstrainedengineeringdesignmethodforconstantcurrentremotepowersupplysystemofmeshtypecabledunderwaterinformationnetworks
AT xichenwang constrainedengineeringdesignmethodforconstantcurrentremotepowersupplysystemofmeshtypecabledunderwaterinformationnetworks
AT xiaoruiqiao constrainedengineeringdesignmethodforconstantcurrentremotepowersupplysystemofmeshtypecabledunderwaterinformationnetworks
AT xuejunzhou constrainedengineeringdesignmethodforconstantcurrentremotepowersupplysystemofmeshtypecabledunderwaterinformationnetworks