Modern approaches to estimation of power quality

One of the most important properties of the electric power system is its observability. Ensuring observability is relevant not only for power flows and reliability indicators of power supply, but also for power quality indicators, in particular, the non-sinusoidal shape of the supply voltage. Increa...

Full description

Bibliographic Details
Main Authors: K. V. Suslov, N. N. Solonina, D. O. Gerasimov
Format: Article
Language:English
Published: Kazan State Power Engineering University 2018-02-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/417
_version_ 1797762185766633472
author K. V. Suslov
N. N. Solonina
D. O. Gerasimov
author_facet K. V. Suslov
N. N. Solonina
D. O. Gerasimov
author_sort K. V. Suslov
collection DOAJ
description One of the most important properties of the electric power system is its observability. Ensuring observability is relevant not only for power flows and reliability indicators of power supply, but also for power quality indicators, in particular, the non-sinusoidal shape of the supply voltage. Increasingly, the use of elements of power electronics in intelligent power systems, and its application will grow in the future. This leads to the appearance of harmonic components of higher orders of current and voltage. The objects of the power system can be either sources or receivers of harmonics. In this regard, the actual task is to assess the impact of individual objects on the quality of electrical energy in the power system. The observability of Проблемы энергетики, 2017, том 19, № 7-8 86 power systems can be realized by the application of the phasor measurement units (PMU). In this paper, the authors suggest using a distributed system for monitoring the power quality by using the existing PMU infrastructure. This will allow for continuous monitoring of the level of harmonic oscillations in different sections of the power system. Especially this event should be used for isolated power supply systems.
first_indexed 2024-03-12T19:23:41Z
format Article
id doaj.art-498ebc045a4f443d8515ba3f60f8d036
institution Directory Open Access Journal
issn 1998-9903
language English
last_indexed 2024-03-12T19:23:41Z
publishDate 2018-02-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj.art-498ebc045a4f443d8515ba3f60f8d0362023-08-02T04:57:50ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032018-02-01197-8859310.30724/1998-9903-2017-19-7-8-85-93417Modern approaches to estimation of power qualityK. V. Suslov0N. N. Solonina1D. O. Gerasimov2Irkutsk National Research Technical University, IrkutskIrkutsk National Research Technical University, IrkutskIrkutsk National Research Technical University, IrkutskOne of the most important properties of the electric power system is its observability. Ensuring observability is relevant not only for power flows and reliability indicators of power supply, but also for power quality indicators, in particular, the non-sinusoidal shape of the supply voltage. Increasingly, the use of elements of power electronics in intelligent power systems, and its application will grow in the future. This leads to the appearance of harmonic components of higher orders of current and voltage. The objects of the power system can be either sources or receivers of harmonics. In this regard, the actual task is to assess the impact of individual objects on the quality of electrical energy in the power system. The observability of Проблемы энергетики, 2017, том 19, № 7-8 86 power systems can be realized by the application of the phasor measurement units (PMU). In this paper, the authors suggest using a distributed system for monitoring the power quality by using the existing PMU infrastructure. This will allow for continuous monitoring of the level of harmonic oscillations in different sections of the power system. Especially this event should be used for isolated power supply systems.https://www.energyret.ru/jour/article/view/417power qualityisolated power supply systemsvoltage and current harmonicsdistributed power quality monitoring
spellingShingle K. V. Suslov
N. N. Solonina
D. O. Gerasimov
Modern approaches to estimation of power quality
Известия высших учебных заведений: Проблемы энергетики
power quality
isolated power supply systems
voltage and current harmonics
distributed power quality monitoring
title Modern approaches to estimation of power quality
title_full Modern approaches to estimation of power quality
title_fullStr Modern approaches to estimation of power quality
title_full_unstemmed Modern approaches to estimation of power quality
title_short Modern approaches to estimation of power quality
title_sort modern approaches to estimation of power quality
topic power quality
isolated power supply systems
voltage and current harmonics
distributed power quality monitoring
url https://www.energyret.ru/jour/article/view/417
work_keys_str_mv AT kvsuslov modernapproachestoestimationofpowerquality
AT nnsolonina modernapproachestoestimationofpowerquality
AT dogerasimov modernapproachestoestimationofpowerquality