Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucoma

Benjamin Abramowitz,1 Nisha Chadha,2 Amr Kouchouk,3 Rashed Alhabshan,4 David A Belyea,4 Tania Lamba4 1Glaucoma Department, Eye Consultants of Northern Virginia, Springfield, VA, USA; 2Icahn School of Medicine at Mount Sinai/New York Eye and Ear, Eye and Vision Research Institute, New York, NY, USA;...

Full description

Bibliographic Details
Main Authors: Abramowitz B, Chadha N, Kouchouk A, Alhabshan R, Belyea DA, Lamba T
Format: Article
Language:English
Published: Dove Medical Press 2018-08-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/selective-laser-trabeculoplasty-vs-micropulse-laser-trabeculoplasty-in-peer-reviewed-article-OPTH
_version_ 1819021712489971712
author Abramowitz B
Chadha N
Kouchouk A
Alhabshan R
Belyea DA
Lamba T
author_facet Abramowitz B
Chadha N
Kouchouk A
Alhabshan R
Belyea DA
Lamba T
author_sort Abramowitz B
collection DOAJ
description Benjamin Abramowitz,1 Nisha Chadha,2 Amr Kouchouk,3 Rashed Alhabshan,4 David A Belyea,4 Tania Lamba4 1Glaucoma Department, Eye Consultants of Northern Virginia, Springfield, VA, USA; 2Icahn School of Medicine at Mount Sinai/New York Eye and Ear, Eye and Vision Research Institute, New York, NY, USA; 3Cornea Department, Atlantis Eyecare, Torrance, CA, USA; 4Department of Ophthalmology, The George Washington University, Washington, DC, USA Aim: The aim of this study was to prospectively compare the efficacy, safety, and tolerability of selective laser trabeculoplasty (SLT) vs micropulse laser trabeculoplasty (MLT) in reducing intraocular pressure (IOP) in open-angle glaucoma patients. Patients and methods: In all, 38 patients were randomized to 360° MLT and 31 patients were randomized to 360° SLT. IOP was measured at intervals of 1 hour and 1, 1–6, 6–12, 6–24, 24–36, and 36–52 weeks. Patients completed a survey 1 week after the procedure. Patients with end-stage, neovascular, uveitic, or angle-closure glaucoma were excluded. Treatment response was defined as an IOP reduction of ≥20.0% or ≥3 mmHg from baseline. Results: IOP was lowered to ≥3 mmHg from baseline among 37.0% of the micropulse patients and 36.0% of patients in the selective laser group at 24–52 weeks. Similarly, 29.6% of the micropulse patients and 36.0% of the selective laser patients experienced a 20.0% IOP decrease from baseline during the 24–52-week interval (P=0.77). Both groups revealed similar reductions in IOP as absolute values and percentage decreases from baseline at all intervals up to 52 weeks post treatment. There were more treatment failures in the micropulse group up to 52 weeks post laser treatment; however, this was not statistically significant. The micropulse group reported less pain both during and after the procedure (P=0.005). Conclusion: Micropulse trabeculoplasty has demonstrated similar efficacy to SLT over a 52-week follow-up period with less discomfort experienced both during and after the procedure. Keywords: randomized controlled trial, selective laser trabeculoplasty, micropulse, glaucoma, intraocular pressure
first_indexed 2024-12-21T04:11:28Z
format Article
id doaj.art-49bd4a060cd0444ca160899be353a4cc
institution Directory Open Access Journal
issn 1177-5483
language English
last_indexed 2024-12-21T04:11:28Z
publishDate 2018-08-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj.art-49bd4a060cd0444ca160899be353a4cc2022-12-21T19:16:27ZengDove Medical PressClinical Ophthalmology1177-54832018-08-01Volume 121599160440185Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucomaAbramowitz BChadha NKouchouk AAlhabshan RBelyea DALamba TBenjamin Abramowitz,1 Nisha Chadha,2 Amr Kouchouk,3 Rashed Alhabshan,4 David A Belyea,4 Tania Lamba4 1Glaucoma Department, Eye Consultants of Northern Virginia, Springfield, VA, USA; 2Icahn School of Medicine at Mount Sinai/New York Eye and Ear, Eye and Vision Research Institute, New York, NY, USA; 3Cornea Department, Atlantis Eyecare, Torrance, CA, USA; 4Department of Ophthalmology, The George Washington University, Washington, DC, USA Aim: The aim of this study was to prospectively compare the efficacy, safety, and tolerability of selective laser trabeculoplasty (SLT) vs micropulse laser trabeculoplasty (MLT) in reducing intraocular pressure (IOP) in open-angle glaucoma patients. Patients and methods: In all, 38 patients were randomized to 360° MLT and 31 patients were randomized to 360° SLT. IOP was measured at intervals of 1 hour and 1, 1–6, 6–12, 6–24, 24–36, and 36–52 weeks. Patients completed a survey 1 week after the procedure. Patients with end-stage, neovascular, uveitic, or angle-closure glaucoma were excluded. Treatment response was defined as an IOP reduction of ≥20.0% or ≥3 mmHg from baseline. Results: IOP was lowered to ≥3 mmHg from baseline among 37.0% of the micropulse patients and 36.0% of patients in the selective laser group at 24–52 weeks. Similarly, 29.6% of the micropulse patients and 36.0% of the selective laser patients experienced a 20.0% IOP decrease from baseline during the 24–52-week interval (P=0.77). Both groups revealed similar reductions in IOP as absolute values and percentage decreases from baseline at all intervals up to 52 weeks post treatment. There were more treatment failures in the micropulse group up to 52 weeks post laser treatment; however, this was not statistically significant. The micropulse group reported less pain both during and after the procedure (P=0.005). Conclusion: Micropulse trabeculoplasty has demonstrated similar efficacy to SLT over a 52-week follow-up period with less discomfort experienced both during and after the procedure. Keywords: randomized controlled trial, selective laser trabeculoplasty, micropulse, glaucoma, intraocular pressurehttps://www.dovepress.com/selective-laser-trabeculoplasty-vs-micropulse-laser-trabeculoplasty-in-peer-reviewed-article-OPTHrandomized controlled trialselective laser trabeculoplastymicropulseglaucomaintraocular pressure (IOP)
spellingShingle Abramowitz B
Chadha N
Kouchouk A
Alhabshan R
Belyea DA
Lamba T
Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucoma
Clinical Ophthalmology
randomized controlled trial
selective laser trabeculoplasty
micropulse
glaucoma
intraocular pressure (IOP)
title Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucoma
title_full Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucoma
title_fullStr Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucoma
title_full_unstemmed Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucoma
title_short Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucoma
title_sort selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open angle glaucoma
topic randomized controlled trial
selective laser trabeculoplasty
micropulse
glaucoma
intraocular pressure (IOP)
url https://www.dovepress.com/selective-laser-trabeculoplasty-vs-micropulse-laser-trabeculoplasty-in-peer-reviewed-article-OPTH
work_keys_str_mv AT abramowitzb selectivelasertrabeculoplastyvsmicropulselasertrabeculoplastyinopenangleglaucoma
AT chadhan selectivelasertrabeculoplastyvsmicropulselasertrabeculoplastyinopenangleglaucoma
AT kouchouka selectivelasertrabeculoplastyvsmicropulselasertrabeculoplastyinopenangleglaucoma
AT alhabshanr selectivelasertrabeculoplastyvsmicropulselasertrabeculoplastyinopenangleglaucoma
AT belyeada selectivelasertrabeculoplastyvsmicropulselasertrabeculoplastyinopenangleglaucoma
AT lambat selectivelasertrabeculoplastyvsmicropulselasertrabeculoplastyinopenangleglaucoma