Measurement of the electrical quantities of the wet scrubber
With the aim of reducing environmental, energy and quality problems in the field of farming of animal species, laboratory for agricultural technique in animal husbandry, Department of Agricultural Engineering, Faculty of Agriculture, University of Novi Sad, integrally develops a system for wet air p...
Główni autorzy: | , |
---|---|
Format: | Artykuł |
Język: | English |
Wydane: |
National Society of Processing and Energy in Agriculture, Novi Sad
2022-01-01
|
Seria: | Journal on Processing and Energy in Agriculture |
Hasła przedmiotowe: | |
Dostęp online: | https://scindeks-clanci.ceon.rs/data/pdf/1821-4487/2022/1821-44872203095Z.pdf |
_version_ | 1827973906203410432 |
---|---|
author | Zoranović Miodrag Ivanišević Mladen |
author_facet | Zoranović Miodrag Ivanišević Mladen |
author_sort | Zoranović Miodrag |
collection | DOAJ |
description | With the aim of reducing environmental, energy and quality problems in the field of farming of animal species, laboratory for agricultural technique in animal husbandry, Department of Agricultural Engineering, Faculty of Agriculture, University of Novi Sad, integrally develops a system for wet air purification, wet scrubber, and its energy control. The goal of electrical measurements in a wet scrubber is to determine instantaneous and interval-accurate values of electrical quantities, defined by physical methods. Devices for electrical measurements give precise values of basic electrical quantities: current, electromotive force, voltage, impedance, electrical work, power, and energy. Simple periodic voltages and currents are crucial for wet scrubber drive elements. They are determined by three quantities: amplitude, frequency, and phase. The paper presents the basic patterns for the measured values of wet scrubber drive elements: AC operation, AC power, AC power with active resistances in the circuit and AC power with impedance in the electric circuit. The presence of many drive elements for partial operational actions in a wet scrubber is the basic reason for choosing a central atomizer, as the object of methodologically original energy analysis of this work. |
first_indexed | 2024-04-09T19:46:21Z |
format | Article |
id | doaj.art-4a8de1c74ec74e87b9f30effc059fc8d |
institution | Directory Open Access Journal |
issn | 1821-4487 2956-0195 |
language | English |
last_indexed | 2024-04-09T19:46:21Z |
publishDate | 2022-01-01 |
publisher | National Society of Processing and Energy in Agriculture, Novi Sad |
record_format | Article |
series | Journal on Processing and Energy in Agriculture |
spelling | doaj.art-4a8de1c74ec74e87b9f30effc059fc8d2023-04-03T15:51:58ZengNational Society of Processing and Energy in Agriculture, Novi SadJournal on Processing and Energy in Agriculture1821-44872956-01952022-01-01263-4951001821-44872203095ZMeasurement of the electrical quantities of the wet scrubberZoranović Miodrag0Ivanišević Mladen1Univerzitet u Novom Sadu, Poljoprivredni fakultet, Novi Sad, SerbiaUniverzitet u Novom Sadu, Poljoprivredni fakultet, Novi Sad, SerbiaWith the aim of reducing environmental, energy and quality problems in the field of farming of animal species, laboratory for agricultural technique in animal husbandry, Department of Agricultural Engineering, Faculty of Agriculture, University of Novi Sad, integrally develops a system for wet air purification, wet scrubber, and its energy control. The goal of electrical measurements in a wet scrubber is to determine instantaneous and interval-accurate values of electrical quantities, defined by physical methods. Devices for electrical measurements give precise values of basic electrical quantities: current, electromotive force, voltage, impedance, electrical work, power, and energy. Simple periodic voltages and currents are crucial for wet scrubber drive elements. They are determined by three quantities: amplitude, frequency, and phase. The paper presents the basic patterns for the measured values of wet scrubber drive elements: AC operation, AC power, AC power with active resistances in the circuit and AC power with impedance in the electric circuit. The presence of many drive elements for partial operational actions in a wet scrubber is the basic reason for choosing a central atomizer, as the object of methodologically original energy analysis of this work.https://scindeks-clanci.ceon.rs/data/pdf/1821-4487/2022/1821-44872203095Z.pdfairwet filtercurrentvoltageimpedancepowermeasurement |
spellingShingle | Zoranović Miodrag Ivanišević Mladen Measurement of the electrical quantities of the wet scrubber Journal on Processing and Energy in Agriculture air wet filter current voltage impedance power measurement |
title | Measurement of the electrical quantities of the wet scrubber |
title_full | Measurement of the electrical quantities of the wet scrubber |
title_fullStr | Measurement of the electrical quantities of the wet scrubber |
title_full_unstemmed | Measurement of the electrical quantities of the wet scrubber |
title_short | Measurement of the electrical quantities of the wet scrubber |
title_sort | measurement of the electrical quantities of the wet scrubber |
topic | air wet filter current voltage impedance power measurement |
url | https://scindeks-clanci.ceon.rs/data/pdf/1821-4487/2022/1821-44872203095Z.pdf |
work_keys_str_mv | AT zoranovicmiodrag measurementoftheelectricalquantitiesofthewetscrubber AT ivanisevicmladen measurementoftheelectricalquantitiesofthewetscrubber |