Investigation and Analysis of Stress and Deformation Monitoring of Long-Span Steel Roof Trusses
Structural stress and deformation monitoring and analysis were carried out for the 54 m long-span steel roof truss. To ensure the safety of the construction process, the stress and deformation of the steel roof trusses were monitored throughout the construction process. The numerical modeling of the...
Main Authors: | , , , |
---|---|
格式: | Article |
語言: | English |
出版: |
MDPI AG
2023-02-01
|
叢編: | Buildings |
主題: | |
在線閱讀: | https://www.mdpi.com/2075-5309/13/2/398 |
_version_ | 1827758170592772096 |
---|---|
author | Cun Hui Yongkang Jiao Mingliang Liu Ran Hai |
author_facet | Cun Hui Yongkang Jiao Mingliang Liu Ran Hai |
author_sort | Cun Hui |
collection | DOAJ |
description | Structural stress and deformation monitoring and analysis were carried out for the 54 m long-span steel roof truss. To ensure the safety of the construction process, the stress and deformation of the steel roof trusses were monitored throughout the construction process. The numerical modeling of the structures with six different working conditions was carried out, and the points with the most critical values of stress and deformation were found. This work provides a theoretical basis for field monitoring during and after construction. The results show that the maximum vertical displacement of a steel roof truss during all modeled working conditions and the maximum measured displacement are within the Chinese building code’s requirements. The maximum value of stress found during analysis of the structure during the construction process and the maximum measured stress are much less than the yield stress. The structural stress remains in the elastic range. The reasons for the differences between the calculated and measured results were analyzed. |
first_indexed | 2024-03-11T09:03:54Z |
format | Article |
id | doaj.art-4aadb87e6ab847e190324bde719e6da1 |
institution | Directory Open Access Journal |
issn | 2075-5309 |
language | English |
last_indexed | 2024-03-11T09:03:54Z |
publishDate | 2023-02-01 |
publisher | MDPI AG |
record_format | Article |
series | Buildings |
spelling | doaj.art-4aadb87e6ab847e190324bde719e6da12023-11-16T19:32:05ZengMDPI AGBuildings2075-53092023-02-0113239810.3390/buildings13020398Investigation and Analysis of Stress and Deformation Monitoring of Long-Span Steel Roof TrussesCun Hui0Yongkang Jiao1Mingliang Liu2Ran Hai3School of Architecture and Civil Engineering, Zhongyuan University of Technology, Zhengzhou 450007, ChinaSchool of Architecture and Civil Engineering, Zhongyuan University of Technology, Zhengzhou 450007, ChinaSchool of Civil Engineering, Chang’an University, Xi’an 710061, ChinaSchool of Architecture and Civil Engineering, Zhongyuan University of Technology, Zhengzhou 450007, ChinaStructural stress and deformation monitoring and analysis were carried out for the 54 m long-span steel roof truss. To ensure the safety of the construction process, the stress and deformation of the steel roof trusses were monitored throughout the construction process. The numerical modeling of the structures with six different working conditions was carried out, and the points with the most critical values of stress and deformation were found. This work provides a theoretical basis for field monitoring during and after construction. The results show that the maximum vertical displacement of a steel roof truss during all modeled working conditions and the maximum measured displacement are within the Chinese building code’s requirements. The maximum value of stress found during analysis of the structure during the construction process and the maximum measured stress are much less than the yield stress. The structural stress remains in the elastic range. The reasons for the differences between the calculated and measured results were analyzed.https://www.mdpi.com/2075-5309/13/2/398steel roof trusslong-spanstress and deformationhealth monitoringnumerical simulation |
spellingShingle | Cun Hui Yongkang Jiao Mingliang Liu Ran Hai Investigation and Analysis of Stress and Deformation Monitoring of Long-Span Steel Roof Trusses Buildings steel roof truss long-span stress and deformation health monitoring numerical simulation |
title | Investigation and Analysis of Stress and Deformation Monitoring of Long-Span Steel Roof Trusses |
title_full | Investigation and Analysis of Stress and Deformation Monitoring of Long-Span Steel Roof Trusses |
title_fullStr | Investigation and Analysis of Stress and Deformation Monitoring of Long-Span Steel Roof Trusses |
title_full_unstemmed | Investigation and Analysis of Stress and Deformation Monitoring of Long-Span Steel Roof Trusses |
title_short | Investigation and Analysis of Stress and Deformation Monitoring of Long-Span Steel Roof Trusses |
title_sort | investigation and analysis of stress and deformation monitoring of long span steel roof trusses |
topic | steel roof truss long-span stress and deformation health monitoring numerical simulation |
url | https://www.mdpi.com/2075-5309/13/2/398 |
work_keys_str_mv | AT cunhui investigationandanalysisofstressanddeformationmonitoringoflongspansteelrooftrusses AT yongkangjiao investigationandanalysisofstressanddeformationmonitoringoflongspansteelrooftrusses AT mingliangliu investigationandanalysisofstressanddeformationmonitoringoflongspansteelrooftrusses AT ranhai investigationandanalysisofstressanddeformationmonitoringoflongspansteelrooftrusses |