Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber

In this piece of study, the design and development of a low cost vacuum chamber with different ports are mentioned. I-V characteristic of Langmuir Probe is obtained using the primary data of the experimental set up for ‘single probe method’ in nitrogen seeded arc plasma at atmospheric pressure The...

Full description

Bibliographic Details
Main Authors: Vijay Kumar Jha, Lekha Nath Mishra, Bijoyendra Narayan
Format: Article
Language:English
Published: Department of Physics, Mahendra Morang Adarsh Multiple Campus, Tribhuvan University 2018-11-01
Series:Bibechana
Subjects:
Online Access:https://www.nepjol.info/index.php/BIBECHANA/article/view/20839
_version_ 1797193978063355904
author Vijay Kumar Jha
Lekha Nath Mishra
Bijoyendra Narayan
author_facet Vijay Kumar Jha
Lekha Nath Mishra
Bijoyendra Narayan
author_sort Vijay Kumar Jha
collection DOAJ
description In this piece of study, the design and development of a low cost vacuum chamber with different ports are mentioned. I-V characteristic of Langmuir Probe is obtained using the primary data of the experimental set up for ‘single probe method’ in nitrogen seeded arc plasma at atmospheric pressure The floating potential was found to be 36V and the electron density to be 1.24 ´ 104 K. Variation in electron density of the arc plasma with probe potential is also studied at low pressure range from 10 Nm-2 (0.10 mbar) to 20 Nm-2. BIBECHANA 16 (2019) 1-6
first_indexed 2024-04-24T05:48:58Z
format Article
id doaj.art-4ac95e80fbdd4ab1a9de05779777d4bf
institution Directory Open Access Journal
issn 2091-0762
2382-5340
language English
last_indexed 2024-04-24T05:48:58Z
publishDate 2018-11-01
publisher Department of Physics, Mahendra Morang Adarsh Multiple Campus, Tribhuvan University
record_format Article
series Bibechana
spelling doaj.art-4ac95e80fbdd4ab1a9de05779777d4bf2024-04-23T13:05:20ZengDepartment of Physics, Mahendra Morang Adarsh Multiple Campus, Tribhuvan UniversityBibechana2091-07622382-53402018-11-011610.3126/bibechana.v16i0.2083916182Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamberVijay Kumar Jha0Lekha Nath Mishra1Bijoyendra Narayan2Central Department of Physics, Kirtipur, Tribhuvan University, KathmanduPatan Multiple Campus, Patandhoka, Lalitpur, Tribhuvan University, KathmanduDr. S. K. Sinha Women’s College, Motihari, B. R. A. Bihar University, Muzaffarpur In this piece of study, the design and development of a low cost vacuum chamber with different ports are mentioned. I-V characteristic of Langmuir Probe is obtained using the primary data of the experimental set up for ‘single probe method’ in nitrogen seeded arc plasma at atmospheric pressure The floating potential was found to be 36V and the electron density to be 1.24 ´ 104 K. Variation in electron density of the arc plasma with probe potential is also studied at low pressure range from 10 Nm-2 (0.10 mbar) to 20 Nm-2. BIBECHANA 16 (2019) 1-6 https://www.nepjol.info/index.php/BIBECHANA/article/view/20839Arc plasmavacuum chamberplasma parametersoperational constraintsLangmuir Probefloating Potential
spellingShingle Vijay Kumar Jha
Lekha Nath Mishra
Bijoyendra Narayan
Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber
Bibechana
Arc plasma
vacuum chamber
plasma parameters
operational constraints
Langmuir Probe
floating Potential
title Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber
title_full Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber
title_fullStr Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber
title_full_unstemmed Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber
title_short Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber
title_sort experimental set up for the study of plasma parameters in seeded arc plasma using langmuir probes inside low cost vacuum chamber
topic Arc plasma
vacuum chamber
plasma parameters
operational constraints
Langmuir Probe
floating Potential
url https://www.nepjol.info/index.php/BIBECHANA/article/view/20839
work_keys_str_mv AT vijaykumarjha experimentalsetupforthestudyofplasmaparametersinseededarcplasmausinglangmuirprobesinsidelowcostvacuumchamber
AT lekhanathmishra experimentalsetupforthestudyofplasmaparametersinseededarcplasmausinglangmuirprobesinsidelowcostvacuumchamber
AT bijoyendranarayan experimentalsetupforthestudyofplasmaparametersinseededarcplasmausinglangmuirprobesinsidelowcostvacuumchamber