Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber
In this piece of study, the design and development of a low cost vacuum chamber with different ports are mentioned. I-V characteristic of Langmuir Probe is obtained using the primary data of the experimental set up for ‘single probe method’ in nitrogen seeded arc plasma at atmospheric pressure The...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Department of Physics, Mahendra Morang Adarsh Multiple Campus, Tribhuvan University
2018-11-01
|
Series: | Bibechana |
Subjects: | |
Online Access: | https://www.nepjol.info/index.php/BIBECHANA/article/view/20839 |
_version_ | 1797193978063355904 |
---|---|
author | Vijay Kumar Jha Lekha Nath Mishra Bijoyendra Narayan |
author_facet | Vijay Kumar Jha Lekha Nath Mishra Bijoyendra Narayan |
author_sort | Vijay Kumar Jha |
collection | DOAJ |
description |
In this piece of study, the design and development of a low cost vacuum chamber with different ports are mentioned. I-V characteristic of Langmuir Probe is obtained using the primary data of the experimental set up for ‘single probe method’ in nitrogen seeded arc plasma at atmospheric pressure The floating potential was found to be 36V and the electron density to be 1.24 ´ 104 K. Variation in electron density of the arc plasma with probe potential is also studied at low pressure range from 10 Nm-2 (0.10 mbar) to 20 Nm-2.
BIBECHANA 16 (2019) 1-6
|
first_indexed | 2024-04-24T05:48:58Z |
format | Article |
id | doaj.art-4ac95e80fbdd4ab1a9de05779777d4bf |
institution | Directory Open Access Journal |
issn | 2091-0762 2382-5340 |
language | English |
last_indexed | 2024-04-24T05:48:58Z |
publishDate | 2018-11-01 |
publisher | Department of Physics, Mahendra Morang Adarsh Multiple Campus, Tribhuvan University |
record_format | Article |
series | Bibechana |
spelling | doaj.art-4ac95e80fbdd4ab1a9de05779777d4bf2024-04-23T13:05:20ZengDepartment of Physics, Mahendra Morang Adarsh Multiple Campus, Tribhuvan UniversityBibechana2091-07622382-53402018-11-011610.3126/bibechana.v16i0.2083916182Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamberVijay Kumar Jha0Lekha Nath Mishra1Bijoyendra Narayan2Central Department of Physics, Kirtipur, Tribhuvan University, KathmanduPatan Multiple Campus, Patandhoka, Lalitpur, Tribhuvan University, KathmanduDr. S. K. Sinha Women’s College, Motihari, B. R. A. Bihar University, Muzaffarpur In this piece of study, the design and development of a low cost vacuum chamber with different ports are mentioned. I-V characteristic of Langmuir Probe is obtained using the primary data of the experimental set up for ‘single probe method’ in nitrogen seeded arc plasma at atmospheric pressure The floating potential was found to be 36V and the electron density to be 1.24 ´ 104 K. Variation in electron density of the arc plasma with probe potential is also studied at low pressure range from 10 Nm-2 (0.10 mbar) to 20 Nm-2. BIBECHANA 16 (2019) 1-6 https://www.nepjol.info/index.php/BIBECHANA/article/view/20839Arc plasmavacuum chamberplasma parametersoperational constraintsLangmuir Probefloating Potential |
spellingShingle | Vijay Kumar Jha Lekha Nath Mishra Bijoyendra Narayan Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber Bibechana Arc plasma vacuum chamber plasma parameters operational constraints Langmuir Probe floating Potential |
title | Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber |
title_full | Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber |
title_fullStr | Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber |
title_full_unstemmed | Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber |
title_short | Experimental set up for the study of plasma parameters in seeded arc plasma using Langmuir Probes inside low-cost vacuum chamber |
title_sort | experimental set up for the study of plasma parameters in seeded arc plasma using langmuir probes inside low cost vacuum chamber |
topic | Arc plasma vacuum chamber plasma parameters operational constraints Langmuir Probe floating Potential |
url | https://www.nepjol.info/index.php/BIBECHANA/article/view/20839 |
work_keys_str_mv | AT vijaykumarjha experimentalsetupforthestudyofplasmaparametersinseededarcplasmausinglangmuirprobesinsidelowcostvacuumchamber AT lekhanathmishra experimentalsetupforthestudyofplasmaparametersinseededarcplasmausinglangmuirprobesinsidelowcostvacuumchamber AT bijoyendranarayan experimentalsetupforthestudyofplasmaparametersinseededarcplasmausinglangmuirprobesinsidelowcostvacuumchamber |