DEKOLORISASI AIR LIMBAH PENGOLAHAN GURITA MENGGUNAKAN METODE AOT(ADVANCE OXIDATION TREATMENT) DENGAN REAGEN FENTON

ABSTRACT   This research aims to determine the effectiveness of Advance Oxidation Treatment (AOT) method with the use of Fenton reagent in decolorization of octopus canning wastewater’s red colour. The use of Fenton reagent (H2O2 and Fe2+) will produce hydroxyl radicals (∙OH) that will oxidize the...

Full description

Bibliographic Details
Main Authors: Ganden Supriyanto, Khoirun Nisak R, Abdulloh Abdulloh
Format: Article
Language:English
Published: Universitas Airlangga 2018-07-01
Series:Jurnal Kimia Riset
Subjects:
Online Access:https://e-journal.unair.ac.id/JKR/article/view/7798
_version_ 1811320440420827136
author Ganden Supriyanto
Khoirun Nisak R
Abdulloh Abdulloh
author_facet Ganden Supriyanto
Khoirun Nisak R
Abdulloh Abdulloh
author_sort Ganden Supriyanto
collection DOAJ
description ABSTRACT   This research aims to determine the effectiveness of Advance Oxidation Treatment (AOT) method with the use of Fenton reagent in decolorization of octopus canning wastewater’s red colour. The use of Fenton reagent (H2O2 and Fe2+) will produce hydroxyl radicals (∙OH) that will oxidize the red colour so the octopus canning wastewater to be colourless and safe to discharged into the environment. Determination of octopus canning wastewater's decolorization is done by determining the change of red color's intensity using Pt/Co scale. The main parameter in determining the decolorization of octopus canning wastewater using Advanced Oxidation Treatment (AOT) with Fenton reagent are time, concentration of Fe2+, concentration of H2O2, and pH. The maximum decolorization of octopus canning wastewater was reached at following condition rarely 55 minutes, with Fe2+ concentration of 42,86 ppm, H2O2 concentration of 85,71 ppm, and pH 4. With a capacity of red color’s decolorization is 49,08 %.   Key words : Advance Oxidation Treatment (AOT), decolorization, Fenton reagent     ABSTRAK   Penelitian ini bertujuan untuk mengetahui efektifitas metode Advance Oxidation Treatment  (AOT)  dengan menggunaan reagen Fenton dalam mendekolorisasi warna merah yang terdapat dalam air limbah pengolahan gurita. Penggunaan reagen Fenton (H2O2 dan Fe2+) akan menghasilkan radikal hidroksil (∙OH) yang bisa menghilangkan warna merah yang terdapat di dalam limbah sehingga limbah menjadi tidak berwarna dan aman untuk dibuang ke lingkungan. Penentuan dekolorisasi air limbah pengolahan gurita dilakukan dengan menentukan perubahan intensitas warna merah menggunakan skala Pt/Co. Parameter utama yang digunakan dalam metode Advance Oxidation Treatment  (AOT) adalah waktu, konsentrasi Fe2+, konsentrasi H2O2, dan pH. Hasil optimum dari dekolorisasi air limbah pengolahan gurita adalah pada waktu 55 menit, konsentrasi Fe2+ 42,86 ppm, konsentrasi H2O2 85,71 ppm, dan pH 4. Dengan kapasitas dekolorisasi warna merah sebesar 49,08 %.   Kata kunci  : Advance Oxidation Treatment  (AOT), dekolorisasi, reagen Fenton
first_indexed 2024-04-13T12:59:28Z
format Article
id doaj.art-4adbcf06190447249fa5d5392df3bba6
institution Directory Open Access Journal
issn 2528-0414
2528-0422
language English
last_indexed 2024-04-13T12:59:28Z
publishDate 2018-07-01
publisher Universitas Airlangga
record_format Article
series Jurnal Kimia Riset
spelling doaj.art-4adbcf06190447249fa5d5392df3bba62022-12-22T02:45:57ZengUniversitas AirlanggaJurnal Kimia Riset2528-04142528-04222018-07-013161210.20473/jkr.v3i1.77986172DEKOLORISASI AIR LIMBAH PENGOLAHAN GURITA MENGGUNAKAN METODE AOT(ADVANCE OXIDATION TREATMENT) DENGAN REAGEN FENTONGanden Supriyanto0Khoirun Nisak R1Abdulloh Abdulloh2Departemen Kimia, Fakultas Sains dan Teknologi, Universitas AirlanggaDepartemen Kimia, Fakultas Sains dan Teknologi, Universitas Airlangga Mulyorejo, SurabayaDepartemen Kimia, Fakultas Sains dan Teknologi, Universitas AirlanggaABSTRACT   This research aims to determine the effectiveness of Advance Oxidation Treatment (AOT) method with the use of Fenton reagent in decolorization of octopus canning wastewater’s red colour. The use of Fenton reagent (H2O2 and Fe2+) will produce hydroxyl radicals (∙OH) that will oxidize the red colour so the octopus canning wastewater to be colourless and safe to discharged into the environment. Determination of octopus canning wastewater's decolorization is done by determining the change of red color's intensity using Pt/Co scale. The main parameter in determining the decolorization of octopus canning wastewater using Advanced Oxidation Treatment (AOT) with Fenton reagent are time, concentration of Fe2+, concentration of H2O2, and pH. The maximum decolorization of octopus canning wastewater was reached at following condition rarely 55 minutes, with Fe2+ concentration of 42,86 ppm, H2O2 concentration of 85,71 ppm, and pH 4. With a capacity of red color’s decolorization is 49,08 %.   Key words : Advance Oxidation Treatment (AOT), decolorization, Fenton reagent     ABSTRAK   Penelitian ini bertujuan untuk mengetahui efektifitas metode Advance Oxidation Treatment  (AOT)  dengan menggunaan reagen Fenton dalam mendekolorisasi warna merah yang terdapat dalam air limbah pengolahan gurita. Penggunaan reagen Fenton (H2O2 dan Fe2+) akan menghasilkan radikal hidroksil (∙OH) yang bisa menghilangkan warna merah yang terdapat di dalam limbah sehingga limbah menjadi tidak berwarna dan aman untuk dibuang ke lingkungan. Penentuan dekolorisasi air limbah pengolahan gurita dilakukan dengan menentukan perubahan intensitas warna merah menggunakan skala Pt/Co. Parameter utama yang digunakan dalam metode Advance Oxidation Treatment  (AOT) adalah waktu, konsentrasi Fe2+, konsentrasi H2O2, dan pH. Hasil optimum dari dekolorisasi air limbah pengolahan gurita adalah pada waktu 55 menit, konsentrasi Fe2+ 42,86 ppm, konsentrasi H2O2 85,71 ppm, dan pH 4. Dengan kapasitas dekolorisasi warna merah sebesar 49,08 %.   Kata kunci  : Advance Oxidation Treatment  (AOT), dekolorisasi, reagen Fentonhttps://e-journal.unair.ac.id/JKR/article/view/7798advance oxidation treatment (aot)decolorizationfenton reagent
spellingShingle Ganden Supriyanto
Khoirun Nisak R
Abdulloh Abdulloh
DEKOLORISASI AIR LIMBAH PENGOLAHAN GURITA MENGGUNAKAN METODE AOT(ADVANCE OXIDATION TREATMENT) DENGAN REAGEN FENTON
Jurnal Kimia Riset
advance oxidation treatment (aot)
decolorization
fenton reagent
title DEKOLORISASI AIR LIMBAH PENGOLAHAN GURITA MENGGUNAKAN METODE AOT(ADVANCE OXIDATION TREATMENT) DENGAN REAGEN FENTON
title_full DEKOLORISASI AIR LIMBAH PENGOLAHAN GURITA MENGGUNAKAN METODE AOT(ADVANCE OXIDATION TREATMENT) DENGAN REAGEN FENTON
title_fullStr DEKOLORISASI AIR LIMBAH PENGOLAHAN GURITA MENGGUNAKAN METODE AOT(ADVANCE OXIDATION TREATMENT) DENGAN REAGEN FENTON
title_full_unstemmed DEKOLORISASI AIR LIMBAH PENGOLAHAN GURITA MENGGUNAKAN METODE AOT(ADVANCE OXIDATION TREATMENT) DENGAN REAGEN FENTON
title_short DEKOLORISASI AIR LIMBAH PENGOLAHAN GURITA MENGGUNAKAN METODE AOT(ADVANCE OXIDATION TREATMENT) DENGAN REAGEN FENTON
title_sort dekolorisasi air limbah pengolahan gurita menggunakan metode aot advance oxidation treatment dengan reagen fenton
topic advance oxidation treatment (aot)
decolorization
fenton reagent
url https://e-journal.unair.ac.id/JKR/article/view/7798
work_keys_str_mv AT gandensupriyanto dekolorisasiairlimbahpengolahanguritamenggunakanmetodeaotadvanceoxidationtreatmentdenganreagenfenton
AT khoirunnisakr dekolorisasiairlimbahpengolahanguritamenggunakanmetodeaotadvanceoxidationtreatmentdenganreagenfenton
AT abdullohabdulloh dekolorisasiairlimbahpengolahanguritamenggunakanmetodeaotadvanceoxidationtreatmentdenganreagenfenton