Optimization of the Energy-Saving Building Envelopes in Regional Climate

For a large number of monolithic buildings in the Wenzhou area, serious cold air infiltration occurs at night due to the poor insulation performance of the enclosure structure. This results in the indoor temperature often falling below the thermal comfort zone, which is compounded by high relative h...

Full description

Bibliographic Details
Main Authors: Rongdan Diao, Yinqiu Cao, Linzhu Sun, Chen Xu, Fang Yang
Format: Article
Language:English
Published: MDPI AG 2024-01-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/14/2/320
_version_ 1797298754367258624
author Rongdan Diao
Yinqiu Cao
Linzhu Sun
Chen Xu
Fang Yang
author_facet Rongdan Diao
Yinqiu Cao
Linzhu Sun
Chen Xu
Fang Yang
author_sort Rongdan Diao
collection DOAJ
description For a large number of monolithic buildings in the Wenzhou area, serious cold air infiltration occurs at night due to the poor insulation performance of the enclosure structure. This results in the indoor temperature often falling below the thermal comfort zone, which is compounded by high relative humidity. Various types of energy-efficient buildings, considering different envelope structures (exterior walls, roofs, exterior windows, and shading designs), were constructed, taking into account both structural characteristics and residents’ energy consumption habits. The building environment and energy consumption during the transition period (i.e., summer and winter) were analyzed using the ideal solution similarity ranking preference method (TOPSIS) and the building energy simulation software, EnergyPlus 9.5. This analysis aimed to identify four energy-efficient building models closest to the ideal solution. Comparing the indoor environment parameters and load values of the energy-saving buildings with those of the basic building yielded the following results: the average building load of the energy-saving buildings was 79.48 to 122.00 W lower than that of the basic building. The average temperature difference between the exterior walls of the energy-saving buildings and the interior temperature was 0.6 to 1.45 °C lower than that of the basic building. Similarly, the average temperature difference between the exterior windows and the interior temperature of the energy-saving buildings was 0.56 to 0.98 °C lower than that of the basic building. Additionally, the average temperature difference between the roof and room temperature of the energy-saving buildings was 0.54 to 0.39 °C lower than that of the basic building. Furthermore, the average indoor temperature of the energy-saving buildings was 1.50 to 2.11 °C higher than that of the basic building. In addition, when compared with the basic building, the energy-saving buildings could save 5.66 to 16.39 kg of standard coal and reduce CO<sub>2</sub> emissions by 1.60 to 4.47 kg during the transition period. The study of the energy-saving envelope structure combination form in Wenzhou provides a reasonable basis for building an energy-saving envelope structure combination form in the tropical monsoon climate area, which is of great significance for reducing building energy consumption.
first_indexed 2024-03-07T22:39:35Z
format Article
id doaj.art-4b792e727efa4d77a02cf46e2a7e73a8
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-07T22:39:35Z
publishDate 2024-01-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-4b792e727efa4d77a02cf46e2a7e73a82024-02-23T15:09:55ZengMDPI AGBuildings2075-53092024-01-0114232010.3390/buildings14020320Optimization of the Energy-Saving Building Envelopes in Regional ClimateRongdan Diao0Yinqiu Cao1Linzhu Sun2Chen Xu3Fang Yang4College of Civil Engineering and Architecture, Wenzhou University, Wenzhou 325035, ChinaCollege of Civil Engineering and Architecture, Wenzhou University, Wenzhou 325035, ChinaCollege of Civil Engineering and Architecture, Wenzhou University, Wenzhou 325035, ChinaCollege of Civil Engineering and Architecture, Wenzhou University, Wenzhou 325035, ChinaCollege of Civil Engineering and Architecture, Wenzhou University, Wenzhou 325035, ChinaFor a large number of monolithic buildings in the Wenzhou area, serious cold air infiltration occurs at night due to the poor insulation performance of the enclosure structure. This results in the indoor temperature often falling below the thermal comfort zone, which is compounded by high relative humidity. Various types of energy-efficient buildings, considering different envelope structures (exterior walls, roofs, exterior windows, and shading designs), were constructed, taking into account both structural characteristics and residents’ energy consumption habits. The building environment and energy consumption during the transition period (i.e., summer and winter) were analyzed using the ideal solution similarity ranking preference method (TOPSIS) and the building energy simulation software, EnergyPlus 9.5. This analysis aimed to identify four energy-efficient building models closest to the ideal solution. Comparing the indoor environment parameters and load values of the energy-saving buildings with those of the basic building yielded the following results: the average building load of the energy-saving buildings was 79.48 to 122.00 W lower than that of the basic building. The average temperature difference between the exterior walls of the energy-saving buildings and the interior temperature was 0.6 to 1.45 °C lower than that of the basic building. Similarly, the average temperature difference between the exterior windows and the interior temperature of the energy-saving buildings was 0.56 to 0.98 °C lower than that of the basic building. Additionally, the average temperature difference between the roof and room temperature of the energy-saving buildings was 0.54 to 0.39 °C lower than that of the basic building. Furthermore, the average indoor temperature of the energy-saving buildings was 1.50 to 2.11 °C higher than that of the basic building. In addition, when compared with the basic building, the energy-saving buildings could save 5.66 to 16.39 kg of standard coal and reduce CO<sub>2</sub> emissions by 1.60 to 4.47 kg during the transition period. The study of the energy-saving envelope structure combination form in Wenzhou provides a reasonable basis for building an energy-saving envelope structure combination form in the tropical monsoon climate area, which is of great significance for reducing building energy consumption.https://www.mdpi.com/2075-5309/14/2/320single building envelopeTOPSIS methodideal solutionenergy-saving combination mode
spellingShingle Rongdan Diao
Yinqiu Cao
Linzhu Sun
Chen Xu
Fang Yang
Optimization of the Energy-Saving Building Envelopes in Regional Climate
Buildings
single building envelope
TOPSIS method
ideal solution
energy-saving combination mode
title Optimization of the Energy-Saving Building Envelopes in Regional Climate
title_full Optimization of the Energy-Saving Building Envelopes in Regional Climate
title_fullStr Optimization of the Energy-Saving Building Envelopes in Regional Climate
title_full_unstemmed Optimization of the Energy-Saving Building Envelopes in Regional Climate
title_short Optimization of the Energy-Saving Building Envelopes in Regional Climate
title_sort optimization of the energy saving building envelopes in regional climate
topic single building envelope
TOPSIS method
ideal solution
energy-saving combination mode
url https://www.mdpi.com/2075-5309/14/2/320
work_keys_str_mv AT rongdandiao optimizationoftheenergysavingbuildingenvelopesinregionalclimate
AT yinqiucao optimizationoftheenergysavingbuildingenvelopesinregionalclimate
AT linzhusun optimizationoftheenergysavingbuildingenvelopesinregionalclimate
AT chenxu optimizationoftheenergysavingbuildingenvelopesinregionalclimate
AT fangyang optimizationoftheenergysavingbuildingenvelopesinregionalclimate